Hardware Manual
Page 80
Removing or Installing the Cover 1 2 3 1 latch 3 chassis hooks 2 latch release lock Hard Drives Depending on your chassis and backplane, your system has one of the following configurations: • Eight 2.5-inch drive bays • Four 3.5-inch drive bays with a flex bay for the optional tape backup unit • Six 3.5-inch drive bays without the flex bay All chassis support hot-swappable SAS and SATA hard drives, and the 2.5inch-bay chassis also supports hot-swappable SSD hard drives in systems with integrated PERC controllers. 80 Installing System Components Figure 3-3.
Removing or Installing the Cover 1 2 3 1 latch 3 chassis hooks 2 latch release lock Hard Drives Depending on your chassis and backplane, your system has one of the following configurations: • Eight 2.5-inch drive bays • Four 3.5-inch drive bays with a flex bay for the optional tape backup unit • Six 3.5-inch drive bays without the flex bay All chassis support hot-swappable SAS and SATA hard drives, and the 2.5inch-bay chassis also supports hot-swappable SSD hard drives in systems with integrated PERC controllers. 80 Installing System Components Figure 3-3.
Hardware Manual
Page 197
...errors and failures to identify it when you call Dell for technical support. Simple Network Management Protocol. Solid State Drives. striping - system board - Data stored in an array. Symmetric multiprocessing. See RAM. SATA - SCSI - Secure digital flash memory...a 9-pin connector that allows a network manager to I /O bus interface. SSD - The amount of your system's hardware and customize the system's operation by setting features such as the processor(s), RAM, controllers for operation. system memory - Synchronous dynamic random-access memory. System Setup...
...errors and failures to identify it when you call Dell for technical support. Simple Network Management Protocol. Solid State Drives. striping - system board - Data stored in an array. Symmetric multiprocessing. See RAM. SATA - SCSI - Secure digital flash memory...a 9-pin connector that allows a network manager to I /O bus interface. SSD - The amount of your system's hardware and customize the system's operation by setting features such as the processor(s), RAM, controllers for operation. system memory - Synchronous dynamic random-access memory. System Setup...
Hardware Manual
Page 206
...66, 71 serial connector, 20 service-only procedures control panel assembly, 143 SAS backplane, 146 system board, 148 setup password, 72 SSD hard drives, 80 startup accessing system features, 11 storage controller cabling for 2.5-in HDD chassis, 114 cabling for four 3.5-in HDD chassis..., 115 cabling for six 3.5-in HDD chassis, 116 installing, 112 removing, 112 troubleshooting, 167 support contacting Dell, 189 system board connectors, 180 installing, 150 jumpers, 177 removing, 148 system cooling troubleshooting, 159 system features accessing, 11 system messages,...
...66, 71 serial connector, 20 service-only procedures control panel assembly, 143 SAS backplane, 146 system board, 148 setup password, 72 SSD hard drives, 80 startup accessing system features, 11 storage controller cabling for 2.5-in HDD chassis, 114 cabling for four 3.5-in HDD chassis..., 115 cabling for six 3.5-in HDD chassis, 116 installing, 112 removing, 112 troubleshooting, 167 support contacting Dell, 189 system board connectors, 180 installing, 150 jumpers, 177 removing, 148 system cooling troubleshooting, 159 system features accessing, 11 system messages,...
Technical Guide
Page 9
... R710 R810 6 x 2.5‖ 4 x 3.5" with optional flex bay, 6 x 3.5" without flex bay, or 8 x 2.5‖ 6 x 2.5‖ Hot-plug SAS and SATA, nearline SAS and SSD Hot-plug SAS and SATA, nearline SAS and SSD Hot-plug SAS and SATA, SATA SSD ...Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash 2 PCIe x8 G2 2 PCIe x8 + 2 PCIe x4 G2 or 1 x PCIe x16 + 2 PCIe x4 G2 5 PCIe x8 + 2 PCIe x4 PowerEdge R710...
... R710 R810 6 x 2.5‖ 4 x 3.5" with optional flex bay, 6 x 3.5" without flex bay, or 8 x 2.5‖ 6 x 2.5‖ Hot-plug SAS and SATA, nearline SAS and SSD Hot-plug SAS and SATA, nearline SAS and SSD Hot-plug SAS and SATA, SATA SSD ...Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash 2 PCIe x8 G2 2 PCIe x8 + 2 PCIe x4 G2 or 1 x PCIe x16 + 2 PCIe x4 G2 5 PCIe x8 + 2 PCIe x4 PowerEdge R710...
Technical Guide
Page 13
...; CNA (1020) Dual Port Server Adapter Optional add in HBAs: Brocade® 8 GB HBAs Emulex® OCE10102-IX-DCNA iSCSI HBA stand-up adapter Power Supply Energy Smart:..., 600GB 3.5‖ nearline SAS (7,200 rpm): 500GB, 1TB, 2TB 2.5‖ SATA SSD: 50GB, 100GB 2.5‖ SAS SSD: 149GB Solid State Storage Cards: Fusion-io® 160IDSS-160GB ioDrive PCIe solid state ... of cache Remote Management iDRAC6 Enterprise (optional) Dell™ OpenManage™ Systems Management Microsoft® System Center Essential (SCE) 2010 v2 PowerEdge R710 Technical Guide 13 TOE (TCPIP Offload Engine) ...
...; CNA (1020) Dual Port Server Adapter Optional add in HBAs: Brocade® 8 GB HBAs Emulex® OCE10102-IX-DCNA iSCSI HBA stand-up adapter Power Supply Energy Smart:..., 600GB 3.5‖ nearline SAS (7,200 rpm): 500GB, 1TB, 2TB 2.5‖ SATA SSD: 50GB, 100GB 2.5‖ SAS SSD: 149GB Solid State Storage Cards: Fusion-io® 160IDSS-160GB ioDrive PCIe solid state ... of cache Remote Management iDRAC6 Enterprise (optional) Dell™ OpenManage™ Systems Management Microsoft® System Center Essential (SCE) 2010 v2 PowerEdge R710 Technical Guide 13 TOE (TCPIP Offload Engine) ...
Technical Guide
Page 41
Both Serial Attached SCSI (SAS) and Serial ATA (SATA) hard drives are supported. 12.2 Internal Hard Disk Drives The PowerEdge R710 supports up to eight 2.5‖ hard drives or up to the planar. See Table 10 for hard-drive configurations: For SAS.... Form Factor 3.5‖ 3.5‖ 3.5‖ 3.5‖ 2.5‖ 2.5‖ 2.5‖ 2.5‖ 2.5‖ 2.5‖ Table 10. Dell 12 Storage 12.1 Overview The R710 supports three of hard drive Limited SSD and SAS mixing is allowed: o Two 2.5‖ 10,000 rpm SAS drives installed with one or two mini-SAS...
Both Serial Attached SCSI (SAS) and Serial ATA (SATA) hard drives are supported. 12.2 Internal Hard Disk Drives The PowerEdge R710 supports up to eight 2.5‖ hard drives or up to the planar. See Table 10 for hard-drive configurations: For SAS.... Form Factor 3.5‖ 3.5‖ 3.5‖ 3.5‖ 2.5‖ 2.5‖ 2.5‖ 2.5‖ 2.5‖ 2.5‖ Table 10. Dell 12 Storage 12.1 Overview The R710 supports three of hard drive Limited SSD and SAS mixing is allowed: o Two 2.5‖ 10,000 rpm SAS drives installed with one or two mini-SAS...
Technical Guide
Page 42
.... For more information, see the Hard-Drive Indicator Patterns section in the About Your System chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. 12.3 RAID Configurations See Table 11 for status information. Both LEDs are used to indicate certain conditions... under direction of the system. Config Type Table 11. Factory RAID Configurations Non-Mixed drives all SATA, all SAS, or all SSD Configs Description...
.... For more information, see the Hard-Drive Indicator Patterns section in the About Your System chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. 12.3 RAID Configurations See Table 11 for status information. Both LEDs are used to indicate certain conditions... under direction of the system. Config Type Table 11. Factory RAID Configurations Non-Mixed drives all SATA, all SAS, or all SSD Configs Description...
Technical Guide
Page 43
...SSDs- Dell Config Type Configs 7 MSSR1/R1 SAS or SATA- RAID 13 MSSR1/R1-X 14 MSSR1/R5-X PowerEdge R710 Technical Guide Non-Mixed drives all SATA, all SAS, or all SSD ... 5 (PERC 6/i, PERC H700) Integrated SAS/SATA RAID 1/RAID 10 (PERC 6/i, PERC H700) Integrated SAS/SATA RAID 6 (PERC 6/i, PERC H700) Integrated SSD RAID 1 (PERC 6/i, PERC H700) Integrated SSD RAID 5 (PERC 6/i, PERC H700) Integrated SSD RAID 10 (PERC 6/i, PERC H700) Description 2.5‖ = 2 + 2 3.5‖ = 2 + 2 2.5‖ = 2 + 3 3.5‖ = 2 + 3 2.5‖ = 2 + 4 3.5‖ = 2 + 4 2.5‖ = 4 3.5‖ = 4 ...
...SSDs- Dell Config Type Configs 7 MSSR1/R1 SAS or SATA- RAID 13 MSSR1/R1-X 14 MSSR1/R5-X PowerEdge R710 Technical Guide Non-Mixed drives all SATA, all SAS, or all SSD ... 5 (PERC 6/i, PERC H700) Integrated SAS/SATA RAID 1/RAID 10 (PERC 6/i, PERC H700) Integrated SAS/SATA RAID 6 (PERC 6/i, PERC H700) Integrated SSD RAID 1 (PERC 6/i, PERC H700) Integrated SSD RAID 5 (PERC 6/i, PERC H700) Integrated SSD RAID 10 (PERC 6/i, PERC H700) Description 2.5‖ = 2 + 2 3.5‖ = 2 + 2 2.5‖ = 2 + 3 3.5‖ = 2 + 3 2.5‖ = 2 + 4 3.5‖ = 2 + 4 2.5‖ = 4 3.5‖ = 4 ...
Technical Guide
Page 44
...platforms. PowerEdge R710 Technical...Dell Config Type Configs Description Integrated SAS/SATA RAID 15 MSSR1/R10-X 1/RAID 10 (PERC 6/i, PERC H700) Mixed SATA + SAS Min 2xSAS + 1xSATA 2.5": Max 2xSAS + 6xSATA 3.5": Max 2xSAS + 4xSATA Min HDD Max HDD 2.5‖ = 2 + 4 3.5‖ = 2 + 4 2.5‖ = 2 + 6 3.5‖ = 2 + 4 Mixed SSD...R710 internal SAS 6/iR HBA is an expansion card that plugs into the dedicated internal SAS slot on Chip) processor with a PCI Express host interface and DDR2 memory. The PERC 6/i uses the LSI 1078 ROC (RAID on Riser1. It incorporates two four-channel 6 Gb...
...platforms. PowerEdge R710 Technical...Dell Config Type Configs Description Integrated SAS/SATA RAID 15 MSSR1/R10-X 1/RAID 10 (PERC 6/i, PERC H700) Mixed SATA + SAS Min 2xSAS + 1xSATA 2.5": Max 2xSAS + 6xSATA 3.5": Max 2xSAS + 4xSATA Min HDD Max HDD 2.5‖ = 2 + 4 3.5‖ = 2 + 4 2.5‖ = 2 + 6 3.5‖ = 2 + 4 Mixed SSD...R710 internal SAS 6/iR HBA is an expansion card that plugs into the dedicated internal SAS slot on Chip) processor with a PCI Express host interface and DDR2 memory. The PERC 6/i uses the LSI 1078 ROC (RAID on Riser1. It incorporates two four-channel 6 Gb...
Technical Guide
Page 45
...PERC H700) Usage Internal Backplane Storage RAID (HDD, SDD) PERC 6/E Adapter (PERC H800) External SAS/SATA storage PERC 5/E Adapter Legacy external storage PowerEdge R710 Support Slot PCI PCI IO Con Bracket Con RAID Battery Backup Yes-Max 1 Storage slot x8 No x4 int 0, 1, 5, 6, 10, Yes ... dedicated internal SAS slot on the internal H700. Dell 12.4.4 PERC H700 If you want an internal RAID solution, select the PERC H700 or PERC 6/i. It supports the internal 6 Gb/s backplane interface for internal storage options (SAS, SATA, or SSD HDD). PowerEdge R710 Technical Guide 45
...PERC H700) Usage Internal Backplane Storage RAID (HDD, SDD) PERC 6/E Adapter (PERC H800) External SAS/SATA storage PERC 5/E Adapter Legacy external storage PowerEdge R710 Support Slot PCI PCI IO Con Bracket Con RAID Battery Backup Yes-Max 1 Storage slot x8 No x4 int 0, 1, 5, 6, 10, Yes ... dedicated internal SAS slot on the internal H700. Dell 12.4.4 PERC H700 If you want an internal RAID solution, select the PERC H700 or PERC 6/i. It supports the internal 6 Gb/s backplane interface for internal storage options (SAS, SATA, or SSD HDD). PowerEdge R710 Technical Guide 45