Administrator's Guide
Page 53
...Mappings and then Define Host. • Select the Setup tab, and click Manually Define Hosts. • Select the Mappings tab. NOTE: The host name should be the same as the operating system for example, NX3500-Controller-0). The Specify Host Group window is displayed. 9 Select the host group ...Select Yes in Do you created (see Figure ) and enter a User label for your NAS storage, perform one of NASCU (see "Creating a Host Group" on page 41.) in the this window, select Yes. Setting Up Your PowerVault NX3500 Solution 53 The Specify Host Name window is displayed. 6 In Host ...
...Mappings and then Define Host. • Select the Setup tab, and click Manually Define Hosts. • Select the Mappings tab. NOTE: The host name should be the same as the operating system for example, NX3500-Controller-0). The Specify Host Group window is displayed. 9 Select the host group ...Select Yes in Do you created (see Figure ) and enter a User label for your NAS storage, perform one of NASCU (see "Creating a Host Group" on page 41.) in the this window, select Yes. Setting Up Your PowerVault NX3500 Solution 53 The Specify Host Name window is displayed. 6 In Host ...
Administrator's Guide
Page 103
... to remove. 3 Click Remove DMA Server on PowerVault NX3500 103 Displaying Active NDMP Jobs All backup or restore operations currently being processed by the PowerVault NX3500 can manually type in the volume path. Specifying NAS Volume ...of the DMA servers. Modifying DMA Servers List In order to take an NDMP backup of the PowerVault NX3500 NAS system, the Backup Application server (DMA) must be seen on the Action tab and ... that initiated this session. The PowerVault NX3500 system exposes backup volumes at the following information is the exact name as it appears in the...
... to remove. 3 Click Remove DMA Server on PowerVault NX3500 103 Displaying Active NDMP Jobs All backup or restore operations currently being processed by the PowerVault NX3500 can manually type in the volume path. Specifying NAS Volume ...of the DMA servers. Modifying DMA Servers List In order to take an NDMP backup of the PowerVault NX3500 NAS system, the Backup Application server (DMA) must be seen on the Action tab and ... that initiated this session. The PowerVault NX3500 system exposes backup volumes at the following information is the exact name as it appears in the...
Administrator's Guide
Page 160
...was made a replication target without his knowledge. 160 Troubleshooting List all available shares on read -only when it is restored from a backup. 2 Manually create the missing directories. A NAS volume is set to read -only volume. During restore time, the directory structure is recommended to apply a...directory in the same path deleted or altered a directory, which is mounted by mistake. • The user accesses the wrong system due to similarity in name/IP. • The user is accessing a NAS container, which refers to modify a file on the NAS and identify the problematic...
...was made a replication target without his knowledge. 160 Troubleshooting List all available shares on read -only when it is restored from a backup. 2 Manually create the missing directories. A NAS volume is set to read -only volume. During restore time, the directory structure is recommended to apply a...directory in the same path deleted or altered a directory, which is mounted by mistake. • The user accesses the wrong system due to similarity in name/IP. • The user is accessing a NAS container, which refers to modify a file on the NAS and identify the problematic...
Administrator's Guide
Page 166
b Manually create the missing directories to the client. 3 List all available exports on a NAS container. c Remove the export and communicate this to enable the mount. It ... with an authorization to . 166 Troubleshooting The full directory structure is available only when the restore is being mounted by another client. • When multiple users are three options: a Restore the problematic path from backup or remote replication. NFS Mount Path Does Not Exist Description Cause Workaround Client tries to access...
b Manually create the missing directories to the client. 3 List all available exports on a NAS container. c Remove the export and communicate this to enable the mount. It ... with an authorization to . 166 Troubleshooting The full directory structure is available only when the restore is being mounted by another client. • When multiple users are three options: a Restore the problematic path from backup or remote replication. NFS Mount Path Does Not Exist Description Cause Workaround Client tries to access...
Administrator's Guide
Page 177
...Strange UID and GID Numbers on Dell NAS System Files Description Cause Workaround New files created from ubuntu 7.x clients get the UID and GID of the NAS system and verify if there is due to the PowerVault NX3500 mounts in the ubuntu fstab file... conflict exists, manually change the conflicting NAS internal network address using either the NAS Manager or CLI. Troubleshooting 177 As a result, files created from specific network(s), cannot access the PowerVault NX3500 system. Specific Subnet Clients Cannot Access the PowerVault NX3500 System Description Cause Workaround Users (new or...
...Strange UID and GID Numbers on Dell NAS System Files Description Cause Workaround New files created from ubuntu 7.x clients get the UID and GID of the NAS system and verify if there is due to the PowerVault NX3500 mounts in the ubuntu fstab file... conflict exists, manually change the conflicting NAS internal network address using either the NAS Manager or CLI. Troubleshooting 177 As a result, files created from specific network(s), cannot access the PowerVault NX3500 system. Specific Subnet Clients Cannot Access the PowerVault NX3500 System Description Cause Workaround Users (new or...
Placemat
Page 2
...the security certificate, and ensure that JavaScript is available at support.dell.com/manuals. Repeat step 3 and step 4 for the controller and provide a user label. From the management station, launch the PowerVault Configuration Utility and follow the instructions on the management station. ... Manager Client Launching The Configuration Wizard Completing Your Setup 4. It is also available at support.dell.com/manuals. Copy the IQN numbers from the PowerVault NX3500 web interface. In the mappings screen, right-click the host group and select Define→...
...the security certificate, and ensure that JavaScript is available at support.dell.com/manuals. Repeat step 3 and step 4 for the controller and provide a user label. From the management station, launch the PowerVault Configuration Utility and follow the instructions on the management station. ... Manager Client Launching The Configuration Wizard Completing Your Setup 4. It is also available at support.dell.com/manuals. Copy the IQN numbers from the PowerVault NX3500 web interface. In the mappings screen, right-click the host group and select Define→...