iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 398
The details of BIOS.MemSettings.RedundantMemInUse attribute Description Display the current redundant memory setting in BIOS. The details of BIOS.MemSettings.Serialdbgout attribute Description Enables or disables the Serial Debug Out option. ... iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.RedundantMemCfgValid (Read or Write) Table 882. The details of attribute Description Redundant Memory Configuration Valid Legal Values • Invalid • Valid Default Value Write Privilege Not Applicable Server Control License Required iDRAC Express or iDRAC...
The details of BIOS.MemSettings.RedundantMemInUse attribute Description Display the current redundant memory setting in BIOS. The details of BIOS.MemSettings.Serialdbgout attribute Description Enables or disables the Serial Debug Out option. ... iDRAC Express or iDRAC Enterprise Dependency None BIOS.MemSettings.RedundantMemCfgValid (Read or Write) Table 882. The details of attribute Description Redundant Memory Configuration Valid Legal Values • Invalid • Valid Default Value Write Privilege Not Applicable Server Control License Required iDRAC Express or iDRAC...
EMC NVDIMM-N Persistent Memory User Guide
Page 19
... when multibit errors have been detected. If this field is set to Enabled, memory interleaving is supported if a symmetric memory configuration is present in the Persistent Memory System Setup page, Node Interleaving setting also applies to Disabled, the system supports NUMA (asymmetric) memory configurations. Node interleaving is not supported when NVDMM-N is installed. One Shot: System...
... when multibit errors have been detected. If this field is set to Enabled, memory interleaving is supported if a symmetric memory configuration is present in the Persistent Memory System Setup page, Node Interleaving setting also applies to Disabled, the system supports NUMA (asymmetric) memory configurations. Node interleaving is not supported when NVDMM-N is installed. One Shot: System...
EMC NVDIMM-N Persistent Memory User Guide
Page 20
...each option that is enabled in the system. This option is set to Enabled, memory interleaving is supported if a symmetric memory configuration is set to Enable, this field is set to Persistent Memory Interleaving. If set to be saved. If this forces NVDIMMs to Disabled, the system... supports NUMA (asymmetric) memory configurations. This option is set to remove data and/or repurpose the NVDIMM-N. Persistent Memory Enables or disables NVDIMM-N operation. The reset and data erasure will be used to Disable ...
...each option that is enabled in the system. This option is set to Enabled, memory interleaving is supported if a symmetric memory configuration is set to Enable, this field is set to Persistent Memory Interleaving. If set to be saved. If this forces NVDIMMs to Disabled, the system... supports NUMA (asymmetric) memory configurations. This option is set to remove data and/or repurpose the NVDIMM-N. Persistent Memory Enables or disables NVDIMM-N operation. The reset and data erasure will be used to Disable ...
EMC NVDIMM-N Persistent Memory User Guide
Page 27
...the issue persists, contact your service provider. MEM9033 An unsupported Non-Volatile Dual In-line Memory Module (NVDIMM) device is as currently configured. Review the memory configuration and ensure the configuration is of supported life duration and is placed in the log and resolve the issues. MEM9036... The Non-Volatile Dual In-line Memory Module (NVDIMM) devices are defined in the slot [...
...the issue persists, contact your service provider. MEM9033 An unsupported Non-Volatile Dual In-line Memory Module (NVDIMM) device is as currently configured. Review the memory configuration and ensure the configuration is of supported life duration and is placed in the log and resolve the issues. MEM9036... The Non-Volatile Dual In-line Memory Module (NVDIMM) devices are defined in the slot [...
EMC NVDIMM-N Persistent Memory User Guide
Page 31
... supported is recommended that the NVDIMM-N be erased and reset to factory defaults in the original server. This applies to each memory slot and memory configuration, NVDIMM-Ns may generate errors after a memory configuration change. 8 DIMM Configuration Changes Dell EMC recommends that NVDIMM-N data contents be backed up to external storage before making any changes to utilization...
... supported is recommended that the NVDIMM-N be erased and reset to factory defaults in the original server. This applies to each memory slot and memory configuration, NVDIMM-Ns may generate errors after a memory configuration change. 8 DIMM Configuration Changes Dell EMC recommends that NVDIMM-N data contents be backed up to external storage before making any changes to utilization...
EMC Installation and Service Manual
Page 44
... interleaving. Power on the memory configuration of memory that is set to load before you see the following steps: Steps 1. Memory Settings details About this task The Memory Settings screen details are Optimizer Mode, Single Rank Spare Mode, Mode Multi Rank Spare Mode, Mirror Mode, and Dell Fault Resilient Mode. Voltage Video Memory Specifies the amount of...
... interleaving. Power on the memory configuration of memory that is set to load before you see the following steps: Steps 1. Memory Settings details About this task The Memory Settings screen details are Optimizer Mode, Single Rank Spare Mode, Mode Multi Rank Spare Mode, Mirror Mode, and Dell Fault Resilient Mode. Voltage Video Memory Specifies the amount of...
EMC Installation and Service Manual
Page 45
... system begins to load before you see the following steps: Steps 1. If this field is set to Enabled, memory interleaving is supported if a symmetric memory configuration is set to Disabled by default. This option is installed. This option is set to Enabled by default and is... processor idling. On the System Setup Main Menu screen, click System BIOS. 4. Option Description NOTE: The Dell Fault Resilient Mode option establishes an area of memory that supports the feature to load critical applications or enables the operating system kernel to maximize system availability. ADDDC...
... system begins to load before you see the following steps: Steps 1. If this field is set to Enabled, memory interleaving is supported if a symmetric memory configuration is set to Disabled by default. This option is installed. This option is set to Enabled by default and is... processor idling. On the System Setup Main Menu screen, click System BIOS. 4. Option Description NOTE: The Dell Fault Resilient Mode option establishes an area of memory that supports the feature to load critical applications or enables the operating system kernel to maximize system availability. ADDDC...
EMC Installation and Service Manual
Page 57
...cleared. Password Status Enables you to control the reporting mode of applications by performing encryption and decryption by default, optimizes for other memory configurations in App-Direct. TPM Information TPM Status TPM Command Enables you to lock the system password. You can use the System Security...NI Improves the speed of the TPM. Controls the Trusted Platform Module (TPM). When set to None, no command is recommended for 2-2-2 memory configurations in the system. Method 3 is sent to the TPM. On the System BIOS screen, click System Security. This option is set ...
...cleared. Password Status Enables you to control the reporting mode of applications by performing encryption and decryption by default, optimizes for other memory configurations in App-Direct. TPM Information TPM Status TPM Command Enables you to lock the system password. You can use the System Security...NI Improves the speed of the TPM. Controls the Trusted Platform Module (TPM). When set to None, no command is recommended for 2-2-2 memory configurations in the system. Method 3 is sent to the TPM. On the System BIOS screen, click System Security. This option is set ...
EMC Installation and Service Manual
Page 101
... NOTE: MT/s indicates DIMM speed in any valid chipset architectural configuration. The following general guidelines when configuring your system might not boot, stop responding during memory configuration, or operate with reduced memory. Memory channels Proce Channel 0 ssor Channel 1 Proces Slots A1 and ... observe the following are organized as follows: Table 44. The system supports Flexible Memory Configuration, enabling the system to observe these guidelines, your system memory. If your system's memory configurations fail to be 2933 MT/s, 2666 MT/s, 2400 MT/s, or 2133 MT/s...
... NOTE: MT/s indicates DIMM speed in any valid chipset architectural configuration. The following general guidelines when configuring your system might not boot, stop responding during memory configuration, or operate with reduced memory. Memory channels Proce Channel 0 ssor Channel 1 Proces Slots A1 and ... observe the following are organized as follows: Table 44. The system supports Flexible Memory Configuration, enabling the system to observe these guidelines, your system memory. If your system's memory configurations fail to be 2933 MT/s, 2666 MT/s, 2400 MT/s, or 2133 MT/s...
EMC Installation and Service Manual
Page 102
... of RDIMMs populated on processor 1 and 2. • All slots on . • Mixing of more information about the supported NVDIMM-N configurations, see the NVDIMM-N User Guide at the speed of the slowest installed memory module(s). • Populate memory module sockets only if a processor is not supported. • Unbalanced memory configurations will operate at www.dell.com/ poweredgemanuals.
... of RDIMMs populated on processor 1 and 2. • All slots on . • Mixing of more information about the supported NVDIMM-N configurations, see the NVDIMM-N User Guide at the speed of the slowest installed memory module(s). • Populate memory module sockets only if a processor is not supported. • Unbalanced memory configurations will operate at www.dell.com/ poweredgemanuals.
EMC Installation and Service Manual
Page 109
... on NVDIMM-N battery are turned off the system. Handle the memory modules by one rank per channel. Steps 1. NOTE: Memory sparing does not offer protection against a multi-bit uncorrectable error. NOTE: Memory configuration has to 1/2 (ranks/channel). NOTE: Processor 1, processor 2,... and processor 2 population should match. Memory operating modes (continued) Memory Operating Mode Dell Fault Resilient Mode Description With single rank memory sparing enabled, the system memory available to the operating system is : 3/4 (ranks/channel) × 24 (memory modules) × 16 GB = 288...
... on NVDIMM-N battery are turned off the system. Handle the memory modules by one rank per channel. Steps 1. NOTE: Memory sparing does not offer protection against a multi-bit uncorrectable error. NOTE: Memory configuration has to 1/2 (ranks/channel). NOTE: Processor 1, processor 2,... and processor 2 population should match. Memory operating modes (continued) Memory Operating Mode Dell Fault Resilient Mode Description With single rank memory sparing enabled, the system memory available to the operating system is : 3/4 (ranks/channel) × 24 (memory modules) × 16 GB = 288...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1099
... support. Refer to the product documentation to choose a convenient contact method. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Persistent correctable memory error limit reached for supported memory configurations. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI...
... support. Refer to the product documentation to choose a convenient contact method. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Persistent correctable memory error limit reached for supported memory configurations. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1100
... Chassis Event Proxy MEM0006 Message Arguments Memory device at location arg1 . • arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap...✔ Power Off Power Cycle Reset Chassis Event Proxy MEM0007 Message Arguments Unsupported memory configuration; Memory size is present. • arg1 = location Detailed Description None. check memory device at location arg1 is reduced. 1100 Introduction Recommended Response Action No response...
... Chassis Event Proxy MEM0006 Message Arguments Memory device at location arg1 . • arg1 = location Detailed Description The memory may not be seated correctly, misconfigured, or has failed. Category System Health (MEM = Memory) Severity Severity 3 (Informational) Trap...✔ Power Off Power Cycle Reset Chassis Event Proxy MEM0007 Message Arguments Unsupported memory configuration; Memory size is present. • arg1 = location Detailed Description None. check memory device at location arg1 is reduced. 1100 Introduction Recommended Response Action No response...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1101
... Cycle Reset Chassis Event Proxy Introduction 1101 Recommended Response Action No response action is spare memory. • arg1 = location Detailed Description None. Check memory . Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Unsupported memory configuration. Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI Alert SNMP Alert Email Alert...
... Cycle Reset Chassis Event Proxy Introduction 1101 Recommended Response Action No response action is spare memory. • arg1 = location Detailed Description None. Check memory . Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 LCD Message Unsupported memory configuration. Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI Alert SNMP Alert Email Alert...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1146
...has been placed in was not able to operate as currently configured. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 1146 Introduction MEM9032 Message Arguments The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is unable ...reinstalling the NVDIMM, see the system Owners Manual on the support site. Recommended Response Action Review the memory configuration and make sure the configuration is as per memory rules defined in write-protect mode. OMSA Event ID 5429 OMSA Trap ID 5429 Redfish Event Type Alert...
...has been placed in was not able to operate as currently configured. Category System Health (MEM = Memory) Severity Severity 1 (Critical) Trap/EventID 2265 1146 Introduction MEM9032 Message Arguments The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is unable ...reinstalling the NVDIMM, see the system Owners Manual on the support site. Recommended Response Action Review the memory configuration and make sure the configuration is as per memory rules defined in write-protect mode. OMSA Event ID 5429 OMSA Trap ID 5429 Redfish Event Type Alert...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1416
... action is required. Detailed Description System BIOS has started memory configuration. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Memory configuration started copying image from flash to system memory. Recommended Response Action No response action is required. Category... Message Shadow BIOS. Redfish Event Type No alerts are applicable for this message PST0004 Message Memory Configuration. Severity Severity 3 (Informational) LCD Message CPU Microcode load. Redfish Event Type No alerts are applicable for ...
... action is required. Detailed Description System BIOS has started memory configuration. Category System Health (PST = BIOS POST) Severity Severity 3 (Informational) LCD Message Memory configuration started copying image from flash to system memory. Recommended Response Action No response action is required. Category... Message Shadow BIOS. Redfish Event Type No alerts are applicable for this message PST0004 Message Memory Configuration. Severity Severity 3 (Informational) LCD Message CPU Microcode load. Redfish Event Type No alerts are applicable for ...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1426
...10004; Power Off Power Cycle Reset Chassis Event Proxy PST0130 Message Memory is configured, but is not configurable. Reseat memory devices or reduce system to supported system memory configurations. Check memory devices Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI...10004; ✔ ✔ ✔ Redfish Eventing ✔ 1426 Introduction Detailed Description During memory configuration system BIOS encountered device failures or speed configurations that resulted in system power on , thus the system may not display video.(BIOS POST Exception...
...10004; Power Off Power Cycle Reset Chassis Event Proxy PST0130 Message Memory is configured, but is not configurable. Reseat memory devices or reduce system to supported system memory configurations. Check memory devices Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI...10004; ✔ ✔ ✔ Redfish Eventing ✔ 1426 Introduction Detailed Description During memory configuration system BIOS encountered device failures or speed configurations that resulted in system power on , thus the system may not display video.(BIOS POST Exception...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1433
...Off Power Cycle Reset Chassis Event Proxy PST0142 Message MRC fatal error. This could be related to supported system memory configurations. A socketed TPM module may not display video. This exception occurred early in system power on , thus ...the system may not display video. Recommended Response Action Compare system memory installation to minimum memory configuration. Detailed Description BIOS Memory testing failed. Reduce system configuration to supported system memory configurations. If the problem persists, contact technical support. Detailed Description TXT ...
...Off Power Cycle Reset Chassis Event Proxy PST0142 Message MRC fatal error. This could be related to supported system memory configurations. A socketed TPM module may not display video. This exception occurred early in system power on , thus ...the system may not display video. Recommended Response Action Compare system memory installation to minimum memory configuration. Detailed Description BIOS Memory testing failed. Reduce system configuration to supported system memory configurations. If the problem persists, contact technical support. Detailed Description TXT ...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1435
...10004; Power Off Power Cycle Reset Chassis Event Proxy PST0193 Message BIOS POST memory test failed. Refer to the product documentation to supported system memory configurations. Check memory devices Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI Alert ... OS Log ✔ Power Off Power Cycle Reset Chassis Event Proxy PST0194 Message Remote access controller configuration failed. Reduce system configuration to minimum memory configuration. Recommended Response Action Power cycle the system. This exception occurred early in system power on , thus...
...10004; Power Off Power Cycle Reset Chassis Event Proxy PST0193 Message BIOS POST memory test failed. Refer to the product documentation to supported system memory configurations. Check memory devices Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI Alert ... OS Log ✔ Power Off Power Cycle Reset Chassis Event Proxy PST0194 Message Remote access controller configuration failed. Reduce system configuration to minimum memory configuration. Recommended Response Action Power cycle the system. This exception occurred early in system power on , thus...
Event and Error Message Reference Guide for 14th Generation EMC PowerEdge Servers Version 1.90
Page 1436
...; ✔ ✔ Redfish Eventing ✔ iDRAC CMC LC Log LCD ✔* OS Log ✔ Power Off Power Cycle Reset Chassis Event Proxy PST0196 Message Incorrect memory configuration. 1436 Introduction Check screen message Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing...
...; ✔ ✔ Redfish Eventing ✔ iDRAC CMC LC Log LCD ✔* OS Log ✔ Power Off Power Cycle Reset Chassis Event Proxy PST0196 Message Incorrect memory configuration. 1436 Introduction Check screen message Redfish Event Type Alert iDRAC CMC Filter Visibility ✔ IPMI Alert SNMP Alert Email Alert Remote System Log WS Eventing...