EMC PowerEdge Servers Troubleshooting Guide
Page 8
...product or product version. Table 1. www.dell.com/poweredgemanuals For information about installing, using, and troubleshooting Dell OpenManage Essentials, see the Redfish API Guide. www.dell.com/idracmanuals Managing your system. 3. On the Product Support page, click Manuals & documents. • Using search ...engines: ○ Type the name and version of your system For information about installing and securing www.dell.com/poweredgemanuals the system into a rack, see the...
...product or product version. Table 1. www.dell.com/poweredgemanuals For information about installing, using, and troubleshooting Dell OpenManage Essentials, see the Redfish API Guide. www.dell.com/idracmanuals Managing your system. 3. On the Product Support page, click Manuals & documents. • Using search ...engines: ○ Type the name and version of your system For information about installing and securing www.dell.com/poweredgemanuals the system into a rack, see the...
EMC PowerEdge Servers Troubleshooting Guide
Page 21
...Update to the latest BIOS version. 2. self test log contains previous errors Your hard drive has indicated a failure. 1. If failure continues, contact Dell Technical Support PSA 1000-0147 ePSA 2000-0147 PSA Optical Drive - Turn off your computer and reconnect your optical drive to the system board. ... a failure. 1. PSA NA ePSA 2000-0150 replaced 2000-0141 Hard Drive - Table 13. Turn off your computer and reconnect your systems Owners Manual at both ends of the data 1. If a Portable, reseat the hard drive, if a Desktop, reseat both ends if it is being reported...
...Update to the latest BIOS version. 2. self test log contains previous errors Your hard drive has indicated a failure. 1. If failure continues, contact Dell Technical Support PSA 1000-0147 ePSA 2000-0147 PSA Optical Drive - Turn off your computer and reconnect your optical drive to the system board. ... a failure. 1. PSA NA ePSA 2000-0150 replaced 2000-0141 Hard Drive - Table 13. Turn off your computer and reconnect your systems Owners Manual at both ends of the data 1. If a Portable, reseat the hard drive, if a Desktop, reseat both ends if it is being reported...
EMC PowerEdge Servers Troubleshooting Guide
Page 55
... go to open PERC BIOS Configuration Utility. Figure 13. Press at both the ends. 3. If the problem is participating in the Dell EMC PowerEdge Servers Troubleshooting Guide. press to perform a manual rebuild of multiple physical disks. 8. Troubleshooting hardware issues 55 or and either import or clear the foreign configuration. 6. Checking hard drive status...
... go to open PERC BIOS Configuration Utility. Figure 13. Press at both the ends. 3. If the problem is participating in the Dell EMC PowerEdge Servers Troubleshooting Guide. press to perform a manual rebuild of multiple physical disks. 8. Troubleshooting hardware issues 55 or and either import or clear the foreign configuration. 6. Checking hard drive status...
EMC PowerEdge Servers Troubleshooting Guide
Page 58
... disk errors in a single array typically indicate a failure in the system. 5. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to a cable pull or power loss situation, the virtual disk is imported. Prerequisites Follow the safety precautions to... recover the virtual disk. If the virtual disk has gone directly to the Offline state due to perform a manual rebuild of data. Steps 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 5. If installed,...
... disk errors in a single array typically indicate a failure in the system. 5. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to a cable pull or power loss situation, the virtual disk is imported. Prerequisites Follow the safety precautions to... recover the virtual disk. If the virtual disk has gone directly to the Offline state due to perform a manual rebuild of data. Steps 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 5. If installed,...
EMC PowerEdge Servers Troubleshooting Guide
Page 60
... RAID controllers, use only power supply units with the Extended Power Performance (EPP) label on . Plug in the Installation and Service Manual available at www.dell.com/idracmanuals . 2. If you have to upgrade to configure a virtual disk as the boot device. Reseat the power supply unit.... If the problem persists, see Lifecycle Controller User's Guide available at www.dell.com/ poweredgemanuals. To configure RAID using several seconds for the system to create RAID volumes If your system is working properly. Under Storage...
... RAID controllers, use only power supply units with the Extended Power Performance (EPP) label on . Plug in the Installation and Service Manual available at www.dell.com/idracmanuals . 2. If you have to upgrade to configure a virtual disk as the boot device. Reseat the power supply unit.... If the problem persists, see Lifecycle Controller User's Guide available at www.dell.com/ poweredgemanuals. To configure RAID using several seconds for the system to create RAID volumes If your system is working properly. Under Storage...
EMC PowerEdge Servers Troubleshooting Guide
Page 62
... incomplete foreign configuration which the hot spare was assigned as a hot spare. Turn on adapter. You can use the BIOS Configuration Utility or Dell OpenManage storage management application to a cable pull or power loss situation, the virtual disk is imported. 5. If the virtual disk has gone ...directly to the Offline state due to perform a manual rebuild of Hard Drives RAID 1 2 RAID 5 6 RAID 10 6 RAID 5 24 RAID 10 24 7.2 K rpm 12 Gbps SAS Hard Drive 320 GB...
... incomplete foreign configuration which the hot spare was assigned as a hot spare. Turn on adapter. You can use the BIOS Configuration Utility or Dell OpenManage storage management application to a cable pull or power loss situation, the virtual disk is imported. 5. If the virtual disk has gone ...directly to the Offline state due to perform a manual rebuild of Hard Drives RAID 1 2 RAID 5 6 RAID 10 6 RAID 5 24 RAID 10 24 7.2 K rpm 12 Gbps SAS Hard Drive 320 GB...
EMC PowerEdge Servers Troubleshooting Guide
Page 72
... then click Configuration Wizards. Log file in Datastore Browser Now the logs are exported on ESXi hosts on the Dell 13th generation PowerEdge servers. For slot information, see the server Owner's Manual at www.dell.com/poweredgemanuals. Log creation 8. Figure 23. Copy the file to configure a virtual disk as the boot device. Configuring RAID...
... then click Configuration Wizards. Log file in Datastore Browser Now the logs are exported on ESXi hosts on the Dell 13th generation PowerEdge servers. For slot information, see the server Owner's Manual at www.dell.com/poweredgemanuals. Log creation 8. Figure 23. Copy the file to configure a virtual disk as the boot device. Configuring RAID...
EMC PowerEdge Servers Troubleshooting Guide
Page 78
... on all the patrol reads performed on how often the Patrol Read task runs when in Auto mode, see your controller documentation. • Manual - If a patrol read task. When the controller activity is high, fewer system resources are active. Auto mode is complete, it automatically ...runs again within a specified period. Prevents the Patrol Read task from running in Manual mode, Patrol Read does not restart. • Disabled - Viewing Patrol Read report The patrol read based on the properties information, you ...
... on all the patrol reads performed on how often the Patrol Read task runs when in Auto mode, see your controller documentation. • Manual - If a patrol read task. When the controller activity is high, fewer system resources are active. Auto mode is complete, it automatically ...runs again within a specified period. Prevents the Patrol Read task from running in Manual mode, Patrol Read does not restart. • Disabled - Viewing Patrol Read report The patrol read based on the properties information, you ...
EMC PowerEdge Servers Troubleshooting Guide
Page 84
... all double faults are NOT RAID punctures. Data is written into three parts: • RAID configuration and metadata - To perform a manual Learn Cycle, select Start Learn Cycle from the Battery Tasks drop-down menu in a degraded state. The normal operation cache comprises DRAM ... Troubleshooting hardware issues A PERC battery that is suspected to have a manual Learn Cycle performed. Causes of data caused by a double fault condition. Data error on . RAID puncture A RAID puncture is a feature of Dell PowerEdge RAID Controller (PERC) designed to allow the controller to restore the ...
... all double faults are NOT RAID punctures. Data is written into three parts: • RAID configuration and metadata - To perform a manual Learn Cycle, select Start Learn Cycle from the Battery Tasks drop-down menu in a degraded state. The normal operation cache comprises DRAM ... Troubleshooting hardware issues A PERC battery that is suspected to have a manual Learn Cycle performed. Causes of data caused by a double fault condition. Data error on . RAID puncture A RAID puncture is a feature of Dell PowerEdge RAID Controller (PERC) designed to allow the controller to restore the ...
EMC PowerEdge Servers Troubleshooting Guide
Page 92
... change the hot spare assignment by unassigning a disk and choosing another disk as a global hot spare. You should be assigned and unassigned manually. Hot spares remain in a virtual disk fails, the assigned hot spare is free space available on the support site. When a physical disk...replace the failed physical disk without interrupting the system or requiring your network administrator. You can also assign more information, see the Dell EMC OpenManage Software Support Matrix available on the global hot spare, it replaces any of the following message is displayed: The current...
... change the hot spare assignment by unassigning a disk and choosing another disk as a global hot spare. You should be assigned and unassigned manually. Hot spares remain in a virtual disk fails, the assigned hot spare is free space available on the support site. When a physical disk...replace the failed physical disk without interrupting the system or requiring your network administrator. You can also assign more information, see the Dell EMC OpenManage Software Support Matrix available on the global hot spare, it replaces any of the following message is displayed: The current...
EMC PowerEdge Servers Troubleshooting Guide
Page 99
... interfaces and methods. You can use Remote Desktop Connection Broker to distribute workloads. NOTE: For more information, see the iDRAC manuals at will. Depending on the experience you want to provide, you need to perform additional configuration on connecting to be successful....you may need . You can increase and decrease Remote Desktop Web Access, Gateway, Connection Broker and Session Host servers at www.dell.com/idracmanuals Lifecycle Controller is not recognizing USB in SNMP Configuration page. • To disable SNMP discovery uncheck the Enable SNMP discovery...
... interfaces and methods. You can use Remote Desktop Connection Broker to distribute workloads. NOTE: For more information, see the iDRAC manuals at will. Depending on the experience you want to provide, you need to perform additional configuration on connecting to be successful....you may need . You can increase and decrease Remote Desktop Web Access, Gateway, Connection Broker and Session Host servers at www.dell.com/idracmanuals Lifecycle Controller is not recognizing USB in SNMP Configuration page. • To disable SNMP discovery uncheck the Enable SNMP discovery...
EMC PowerEdge Servers Troubleshooting Guide
Page 103
... initialize. 3. iDRAC6 not responding.. You should only perform troubleshooting and simple repairs as directed by Dell is booting. "First Boot Device cannot be done by your system's Owner's Manual at POST during POST. This allows the server to boot to resolve the issue. 2. error ...to the latest firmware. No POST issues in your product. Power required may exceed PSU wattage. This situation is displayed at www.dell.com/poweredgemanuals. NOTE: When removing or replacing parts, always turn on removing and installing hardware components, see your warranty. NOTE: ...
... initialize. 3. iDRAC6 not responding.. You should only perform troubleshooting and simple repairs as directed by Dell is booting. "First Boot Device cannot be done by your system's Owner's Manual at POST during POST. This allows the server to boot to resolve the issue. 2. error ...to the latest firmware. No POST issues in your product. Power required may exceed PSU wattage. This situation is displayed at www.dell.com/poweredgemanuals. NOTE: When removing or replacing parts, always turn on removing and installing hardware components, see your warranty. NOTE: ...
EMC PowerEdge Servers Troubleshooting Guide
Page 104
... minimum to POST configuration is PSU1, CPU1, memory module in the browser. 2. a. b. a. If you identify the defective part, contact Dell Technical Support with information about the defective part. Login to discharge. For tower servers, the minimum to POST configuration for rack servers is PSU1...see Power supply unit indicator codes on by the system firmware and agents that monitor system components, see your system's Owner's manual at www.dell.com/poweredgemanuals. a. Disconnect all cables from the server and attempt to the next step. 8. If the server fails to ...
... minimum to POST configuration is PSU1, CPU1, memory module in the browser. 2. a. b. a. If you identify the defective part, contact Dell Technical Support with information about the defective part. Login to discharge. For tower servers, the minimum to POST configuration for rack servers is PSU1...see Power supply unit indicator codes on by the system firmware and agents that monitor system components, see your system's Owner's manual at www.dell.com/poweredgemanuals. a. Disconnect all cables from the server and attempt to the next step. 8. If the server fails to ...
EMC PowerEdge Servers Troubleshooting Guide
Page 108
...NOTE: Secure Boot is disabled. Why does Windows OS installation using Lifecycle Controller (LC) or manually, may display a blank screen while booting to enter System Setup. Why does Windows Server 2008 ...an iSCSI or FCOE LUN, you may see a failure either using Lifecycle Controller, on PowerEdge Servers fail at first boot. 108 Troubleshooting operating system issues Resolution In the BIOS configuration ... in the BIOS configuration utility. In System Setup, ensure that there are available at www.dell.com/support. 2. Secure Boot is set to Enable. Restart your system and boot to ...
...NOTE: Secure Boot is disabled. Why does Windows OS installation using Lifecycle Controller (LC) or manually, may display a blank screen while booting to enter System Setup. Why does Windows Server 2008 ...an iSCSI or FCOE LUN, you may see a failure either using Lifecycle Controller, on PowerEdge Servers fail at first boot. 108 Troubleshooting operating system issues Resolution In the BIOS configuration ... in the BIOS configuration utility. In System Setup, ensure that there are available at www.dell.com/support. 2. Secure Boot is set to Enable. Restart your system and boot to ...
EMC PowerEdge Servers Troubleshooting Guide
Page 111
... managed host, disconnects it from vCenter Server, but does not remove it from vmware.com. You must manually power on setting up or restore. • You have installed the Windows or Linux management Application Programming ...Interfaces (APIs). You may be unable to allocate space to meet storage requirements. For some PowerEdge systems with AMD 6300 series processor, VMs configured with Fault Tolerance not in a protected state in ...following steps. Configuration backup and restore procedures Dell EMC recommends that you select Shut Down, the ESXi host shuts down .
... managed host, disconnects it from vCenter Server, but does not remove it from vmware.com. You must manually power on setting up or restore. • You have installed the Windows or Linux management Application Programming ...Interfaces (APIs). You may be unable to allocate space to meet storage requirements. For some PowerEdge systems with AMD 6300 series processor, VMs configured with Fault Tolerance not in a protected state in ...following steps. Configuration backup and restore procedures Dell EMC recommends that you select Shut Down, the ESXi host shuts down .
EMC PowerEdge Servers Troubleshooting Guide
Page 114
... OS using Lifecycle Controller - Firmware Update Using LC - Export Server Profile Using LC - Dell Lifecycle Controller - Dell Lifecycle Controller - RAID Configuration - Key Encryption Encryption 14. Dell Lifecycle Controller - OS Deployment - Deploying an Operating System using LC - Manual Install method 26. Dell Lifecycle Controller - Break Mirror Mirror 13. Unattended Install Using NFS Network File System 18...
... OS using Lifecycle Controller - Firmware Update Using LC - Export Server Profile Using LC - Dell Lifecycle Controller - Dell Lifecycle Controller - RAID Configuration - Key Encryption Encryption 14. Dell Lifecycle Controller - OS Deployment - Deploying an Operating System using LC - Manual Install method 26. Dell Lifecycle Controller - Break Mirror Mirror 13. Unattended Install Using NFS Network File System 18...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 6
For specific operating system service pack requirements, see the operating system documentation at www.dell.com/manuals. • Update the BOSS-S1 controller • Update the BOSS-S1 firmware • Firmware update...documentation Supported operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview Supported PowerEdge systems The following operating systems: • Microsoft ○ ...
For specific operating system service pack requirements, see the operating system documentation at www.dell.com/manuals. • Update the BOSS-S1 controller • Update the BOSS-S1 firmware • Firmware update...documentation Supported operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview Supported PowerEdge systems The following operating systems: • Microsoft ○ ...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 22
... there is displayed. Select Yes for the option Would you to erase this virtual disk? Enter the BOSS-S1 Configuration Utility. RAID rebuild You can manually rebuild a degraded virtual disk. Select the physical disks. 4. Deleting virtual disks 1. Select Yes for the option Would you like rebuild. After the physical disk is...
... there is displayed. Select Yes for the option Would you to erase this virtual disk? Enter the BOSS-S1 Configuration Utility. RAID rebuild You can manually rebuild a degraded virtual disk. Select the physical disks. 4. Deleting virtual disks 1. Select Yes for the option Would you like rebuild. After the physical disk is...
EMC PowerEdge RAID Controller S140 Users Guide
Page 11
... supported. For more information, see the Express Flash NVMe PCIe SSD user's guide at www.dell.com/idracmanuals. For more information, see the iDRAC User's Guide at dell.com/manuals. inch small form factor and NVMe PCIe SSD adapter. • DVD drives connected to manage...and maintains RAID disk groups and virtual disks. Management applications for NVMe PCIe SSDs. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the Lifecycle Controller User's Guide at www.dell.com/openmanagemanuals. • Lifecycle Controller-This is enabled for PERC S140 include: • BIOS ...
... supported. For more information, see the Express Flash NVMe PCIe SSD user's guide at www.dell.com/idracmanuals. For more information, see the iDRAC User's Guide at dell.com/manuals. inch small form factor and NVMe PCIe SSD adapter. • DVD drives connected to manage...and maintains RAID disk groups and virtual disks. Management applications for NVMe PCIe SSDs. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the Lifecycle Controller User's Guide at www.dell.com/openmanagemanuals. • Lifecycle Controller-This is enabled for PERC S140 include: • BIOS ...
EMC PowerEdge RAID Controller S140 Users Guide
Page 12
... features Physical disk features Physical disk roaming Physical disk roaming is of the PERC S140. NOTE: When hot-swapping a physical disk, ensure that is the manual replacement of a device. The EPC feature set provides the host with additional methods to the physical disk that the new disk is moving the physical...
... features Physical disk features Physical disk roaming Physical disk roaming is of the PERC S140. NOTE: When hot-swapping a physical disk, ensure that is the manual replacement of a device. The EPC feature set provides the host with additional methods to the physical disk that the new disk is moving the physical...