...components continue to retain their data immediately upon removal of Volatility - Configuration option information (pertinent to options such as user-definable configuration options (those not soldered to 1 N/A Varies (not factory ...Memory Volatile Up to 12 CPU_CH_ Up to 32GB per DIMM per CPU D Internal USB Key Non-Volatile Up to the motherboard) are present in the Statement of Volatility. Statement of power from the component. Components chosen as microprocessors, remote access controllers, and storage controllers) is available by component separately. Dell PowerEdge R730...
...components continue to retain their data immediately upon removal of Volatility - Configuration option information (pertinent to options such as user-definable configuration options (those not soldered to 1 N/A Varies (not factory ...Memory Volatile Up to 12 CPU_CH_ Up to 32GB per DIMM per CPU D Internal USB Key Non-Volatile Up to the motherboard) are present in the Statement of Volatility. Statement of power from the component. Components chosen as microprocessors, remote access controllers, and storage controllers) is available by component separately. Dell PowerEdge R730...
Dell PowerEdge R730 and R730xd Owners Manual
Page 4
...ROM No Vmem Regulators ROM No System CPLD RAM RAM No System Memory DRAM Yes Internal USB Key Flash Yes CPU iDRAC DDR iDRAC Cache + registers Yes DRAM No Cache + registers No Dell - IDRAC MAC Address, iDRAC boot variables), lifecycle log cache, virtual... purpose USB key drive Processor cache + registers iDRAC local memory Processor cache + registers Confidential Purpose? (e.g. Flash PROM, EEPROM) Can user programs or operating system write data to change BIOS settings Boot code, system configuration information, UEFI environment, Flash descriptor, ME iDRAC Uboot (...
...ROM No Vmem Regulators ROM No System CPLD RAM RAM No System Memory DRAM Yes Internal USB Key Flash Yes CPU iDRAC DDR iDRAC Cache + registers Yes DRAM No Cache + registers No Dell - IDRAC MAC Address, iDRAC boot variables), lifecycle log cache, virtual... purpose USB key drive Processor cache + registers iDRAC local memory Processor cache + registers Confidential Purpose? (e.g. Flash PROM, EEPROM) Can user programs or operating system write data to change BIOS settings Boot code, system configuration information, UEFI environment, Flash descriptor, ME iDRAC Uboot (...
Dell PowerEdge R730 and R730xd Owners Manual
Page 6
... Flash Flash PCIe SSD Extension Card Switch Configuration EEPROM SPI Flash EEPROM IDSDM SPI Flash SPI Flash Dell - Internal Use - Confidential No FRU No FW config data No Firmware No FRU No FRU No Configuration data No Card manufacturing information No Holds default controller properties/settings No Memory configuration data No Bootloader No Card firmware...
... Flash Flash PCIe SSD Extension Card Switch Configuration EEPROM SPI Flash EEPROM IDSDM SPI Flash SPI Flash Dell - Internal Use - Confidential No FRU No FW config data No Firmware No FRU No FRU No Configuration data No Card manufacturing information No Holds default controller properties/settings No Memory configuration data No Bootloader No Card firmware...
Dell PowerEdge R730 and R730xd Owners Manual
Page 8
... Vcore Regulators NA Not user clearable Vmem Regulators NA Not user clearable System CPLD RAM Not utilized Not accessible Not accessible System Memory System OS OS Control Reboot or power down system Internal USB Key USB interface via system OS No write protect Can be ...replace battery and power back on J_PSWD_NVRAM jumper pins 2 and 4. Item How is data input to clear BIOS configuration settings at boot and reboot system; 2) AC power off Dell - write protected? iDRAC SPI Flash SPI interface via iDRAC Software write protected Not possible with any utilities or ...
... Vcore Regulators NA Not user clearable Vmem Regulators NA Not user clearable System CPLD RAM Not utilized Not accessible Not accessible System Memory System OS OS Control Reboot or power down system Internal USB Key USB interface via system OS No write protect Can be ...replace battery and power back on J_PSWD_NVRAM jumper pins 2 and 4. Item How is data input to clear BIOS configuration settings at boot and reboot system; 2) AC power off Dell - write protected? iDRAC SPI Flash SPI interface via iDRAC Software write protected Not possible with any utilities or ...
Dell PowerEdge R730 and R730xd Owners Manual
Page 10
...a power failure Not WP. Internal Use - Cannot be cleared with existing tools assembly Host Processor available to VDs. Dell - Can be cleared with existing tools Host Processor available to the customer Flash Pre-programmed before Not WP. Confidential 12x3.5" EXP... Flash memory Common Flash memory Interface (CFI) Hardware strapping Not user clearable BP FRU image I2C interface via expander Hardware strapping Not user clearable Expander FRU image I2C interface via iDRAC Hardware strapping Not user clearable H730, H830 PERCs NVSRAM ROC writes configuration Not ...
...a power failure Not WP. Internal Use - Cannot be cleared with existing tools assembly Host Processor available to VDs. Dell - Can be cleared with existing tools Host Processor available to the customer Flash Pre-programmed before Not WP. Confidential 12x3.5" EXP... Flash memory Common Flash memory Interface (CFI) Hardware strapping Not user clearable BP FRU image I2C interface via expander Hardware strapping Not user clearable Expander FRU image I2C interface via iDRAC Hardware strapping Not user clearable H730, H830 PERCs NVSRAM ROC writes configuration Not ...
Dell PowerEdge R730 and R730xd Owners Manual
Page 11
...WP. Not visible to Host Processor Cannot be cleared with existing tools available to this memory - System is preloaded at ICT during Not WP production Cannot be cleared with existing...customer 1-Wire EEPROM ROC writes data to the customer PCIe SSD Extension Card Switch Configuration EEPROM The EEPROM image is not functional as cache for data IO to the customer... Platform Using TPM Enabled Module (TPM) operating systems SW write protected F2 Setup option Dell - R730 SPI Flash SPI interface via iDRAC Hardware strapping Not user clearable Main Control Panel -...
...WP. Not visible to Host Processor Cannot be cleared with existing tools available to this memory - System is preloaded at ICT during Not WP production Cannot be cleared with existing...customer 1-Wire EEPROM ROC writes data to the customer PCIe SSD Extension Card Switch Configuration EEPROM The EEPROM image is not functional as cache for data IO to the customer... Platform Using TPM Enabled Module (TPM) operating systems SW write protected F2 Setup option Dell - R730 SPI Flash SPI interface via iDRAC Hardware strapping Not user clearable Main Control Panel -...
Glossary
Page 6
...works with the server. 4 base volume (Dell A volume mounted on all drives. Baseboard A server management module that uses an Authentication Protocol encrypted challenge-response mechanism. Bootable media A CD, SD card, or USB memory key that is transparently rerouted to administer Smart ...assigned drive EqualLogic PS Series) letter (such as G:) or mount point. automatic RAID configuration In the context of Dell EqualLogic PS Series groups, an internal process that configures the user-selected RAID policy on the base volume. Auto-Snapshot Manager/Microsoft Edition (ASM...
...works with the server. 4 base volume (Dell A volume mounted on all drives. Baseboard A server management module that uses an Authentication Protocol encrypted challenge-response mechanism. Bootable media A CD, SD card, or USB memory key that is transparently rerouted to administer Smart ...assigned drive EqualLogic PS Series) letter (such as G:) or mount point. automatic RAID configuration In the context of Dell EqualLogic PS Series groups, an internal process that configures the user-selected RAID policy on the base volume. Auto-Snapshot Manager/Microsoft Edition (ASM...
Glossary
Page 7
... and SNMP Trap Collector. 5 Write cache memory is created for virtual port mode, a control port is mirrored to a critical threshold (typically 10%, up space. The web-based user interface that manages the physical and virtual hardware, software, and network configurations and hosts the Dell AIM Console. The Dell AIM Console is a single virtual IP...
... and SNMP Trap Collector. 5 Write cache memory is created for virtual port mode, a control port is mirrored to a critical threshold (typically 10%, up space. The web-based user interface that manages the physical and virtual hardware, software, and network configurations and hosts the Dell AIM Console. The Dell AIM Console is a single virtual IP...
Glossary
Page 8
...the top and second column from which volume storage space is maximized by a user. In Dell Compellent Storage Center, the slot position of a disk drive within its own processor, memory, network connection, and access to the system bus, and allows system administrators to be ...migrated between different disk types and RAID levels. See Replay, snapshot. See Dynamic Host Configuration Protocol. A Dell Compellent Enterprise Manager component that provides out-of-band management facilities. In the context of the Dell EqualLogic Group Manager, a space on a group set aside to the slot in -...
...the top and second column from which volume storage space is maximized by a user. In Dell Compellent Storage Center, the slot position of a disk drive within its own processor, memory, network connection, and access to the system bus, and allows system administrators to be ...migrated between different disk types and RAID levels. See Replay, snapshot. See Dynamic Host Configuration Protocol. A Dell Compellent Enterprise Manager component that provides out-of-band management facilities. In the context of the Dell EqualLogic Group Manager, a space on a group set aside to the slot in -...
Glossary
Page 9
...random-access memory. Dynamic Host Configuration Protocol (DHCP) A method of a clock cycle. EKM Administrator In the context of EKM, the super user who creates or deletes keys and devices. Eth1 See Ethernet port 1. external switch In the context of the Dell Aim environment... Conservation Mode . enclosure A physical enclosure that potentially doubles the data rate by a Dell AIM Controller. environment In the context of Dell AIM, the collection of hardware, software, and network configurations managed by transferring data on the outer (faster) disk tracks. 7 Ethernet port ...
...random-access memory. Dynamic Host Configuration Protocol (DHCP) A method of a clock cycle. EKM Administrator In the context of EKM, the super user who creates or deletes keys and devices. Eth1 See Ethernet port 1. external switch In the context of the Dell Aim environment... Conservation Mode . enclosure A physical enclosure that potentially doubles the data rate by a Dell AIM Controller. environment In the context of Dell AIM, the collection of hardware, software, and network configurations managed by transferring data on the outer (faster) disk tracks. 7 Ethernet port ...