Information Update - Intel Xeon 5600 Series Processors
Page 2
... low voltage memory modules For information on the memory configuration guidelines, see your system's Hardware Owner's Manual at 1.5 V if any limitations. NOTE: BIOS setup options allow the user to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. Systems with ...1.35 V DDR3L memory operates the memory modules at support.dell.com/manuals. NOTE: Applies to control frequency and voltage configuration within allowable ...
... low voltage memory modules For information on the memory configuration guidelines, see your system's Hardware Owner's Manual at 1.5 V if any limitations. NOTE: BIOS setup options allow the user to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. Systems with ...1.35 V DDR3L memory operates the memory modules at support.dell.com/manuals. NOTE: Applies to control frequency and voltage configuration within allowable ...
Information Update
Page 4
... an addition to Table 3-5 "Examples of PowerEdge M710 Memory Configurations" in the Power Management screen are Maximum Performance, a specified frequency, or Minimum Power. System Memory - Dell™ PowerEdge™ M905 and Dell PowerEdge M805 Architecture DDR2 memory modules, rated for memory power and performance management in your Hardware Owner's Manual. Options for Memory Power and Performance Management...
... an addition to Table 3-5 "Examples of PowerEdge M710 Memory Configurations" in the Power Management screen are Maximum Performance, a specified frequency, or Minimum Power. System Memory - Dell™ PowerEdge™ M905 and Dell PowerEdge M805 Architecture DDR2 memory modules, rated for memory power and performance management in your Hardware Owner's Manual. Options for Memory Power and Performance Management...
Information Update
Page 5
... n_Port3 Mezz_FAB_B_Blade n_Port4 Mezz_FAB_C_Blade n_Port1 Mezz_FAB_C_Blade n_Port2 Mezz_FAB_C_Blade n_Port3 Mezz_FAB_C_Blade n_Port4 I /O module port mapping for a half-height blade with the quad-port mezzanine card. Table 1-1. PowerEdge Blades - In the following table illustrates the I /O Module B1 C1 C2 B2 A2 Port n Port n Port n Port (n+16) Port (n+16) Port n Port n Port (n+16) Port...
... n_Port3 Mezz_FAB_B_Blade n_Port4 Mezz_FAB_C_Blade n_Port1 Mezz_FAB_C_Blade n_Port2 Mezz_FAB_C_Blade n_Port3 Mezz_FAB_C_Blade n_Port4 I /O module port mapping for a half-height blade with the quad-port mezzanine card. Table 1-1. PowerEdge Blades - In the following table illustrates the I /O Module B1 C1 C2 B2 A2 Port n Port n Port n Port (n+16) Port (n+16) Port n Port n Port (n+16) Port...
Information Update
Page 6
... of blade n and LOM3 and LOM4 are the LOM ports of blade (n+8) NOTE: For a detailed mapping of each PowerEdge system, see the document Quadport Capable Hardware For the M1000e Modular Chassis on support.dell.com/manuals. Table 1-2. The following table illustrates the I /O Module A1 B1 C1 C2 B2 A2 Integrated LOM1 Port n Integrated...
... of blade n and LOM3 and LOM4 are the LOM ports of blade (n+8) NOTE: For a detailed mapping of each PowerEdge system, see the document Quadport Capable Hardware For the M1000e Modular Chassis on support.dell.com/manuals. Table 1-2. The following table illustrates the I /O Module A1 B1 C1 C2 B2 A2 Integrated LOM1 Port n Integrated...
Information Update
Page 9
... I /O Module Port Mapping (Dual-Port Mezzanine Cards) The following tables correct portions of Table 1-12 in the "About Your System" section of your Hardware Owner's Manual. Table 1-4. PowerEdge M905, M805, and M710 Blades -
... I /O Module Port Mapping (Dual-Port Mezzanine Cards) The following tables correct portions of Table 1-12 in the "About Your System" section of your Hardware Owner's Manual. Table 1-4. PowerEdge M905, M805, and M710 Blades -
Information Update
Page 13
... following information updates the memory sparing subsections in . 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on your Hardware Owner's Manual and these blades' system information labels. PowerEdge M905 and M805 Blades - Once the CMC update is firmimg.cmc and the filename should...
... following information updates the memory sparing subsections in . 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on your Hardware Owner's Manual and these blades' system information labels. PowerEdge M905 and M805 Blades - Once the CMC update is firmimg.cmc and the filename should...
Information Update
Page 14
...Intel® Gigabit ET Quad-Port Mezzanine Card. NOTE: CMC firmware version 2.0 is required to support FC8 mezzanine cards and I /O modules: • Dell PowerConnect™ M8024 10 Gb Ethernet switch module • Mellanox M2401G DDR Infiniband switch module • Brocade M5424 FC8 switch module • Mellanox M3601Q QDR... Infiniband switch module NOTE: CMC firmware version 1.3 is required to support link tuning in your Hardware Owner's Manual. For detailed information on configuring a particular card, see "Installing System Components" in mezzanine cards.
...Intel® Gigabit ET Quad-Port Mezzanine Card. NOTE: CMC firmware version 2.0 is required to support FC8 mezzanine cards and I /O modules: • Dell PowerConnect™ M8024 10 Gb Ethernet switch module • Mellanox M2401G DDR Infiniband switch module • Brocade M5424 FC8 switch module • Mellanox M3601Q QDR... Infiniband switch module NOTE: CMC firmware version 1.3 is required to support link tuning in your Hardware Owner's Manual. For detailed information on configuring a particular card, see "Installing System Components" in mezzanine cards.
Information Update
Page 15
These modules are available through the network. You can be installed in your Hardware Owner's Manual. Information Update 15 Please note the following modules: • A 10 Gb Ethernet module with four optical SFP+ connectors • A 10 Gb Ethernet module with three ...
These modules are available through the network. You can be installed in your Hardware Owner's Manual. Information Update 15 Please note the following modules: • A 10 Gb Ethernet module with four optical SFP+ connectors • A 10 Gb Ethernet module with three ...
Information Update
Page 22
... light if the drive is installed correctly. If the drive carrier LED does not light, see "Troubleshooting SAS and SATA Drives" in your Hardware Owner's Manual. 22 Information Update 1 Open the hard-drive carrier handle.
... light if the drive is installed correctly. If the drive carrier LED does not light, see "Troubleshooting SAS and SATA Drives" in your Hardware Owner's Manual. 22 Information Update 1 Open the hard-drive carrier handle.
Information Update
Page 23
... you need to power off the blade to release the drive. See "Using the System Setup Program and UEFI Boot Manager" in the Hardware Owner's Manual. Removing a Hard Drive From a Hard-Drive Carrier CAUTION: Always wear a wrist grounding strap when handling equipment with your operating system documentation for more information on...
... you need to power off the blade to release the drive. See "Using the System Setup Program and UEFI Boot Manager" in the Hardware Owner's Manual. Removing a Hard Drive From a Hard-Drive Carrier CAUTION: Always wear a wrist grounding strap when handling equipment with your operating system documentation for more information on...
Information Update - M605, M600
Page 1
...System Power Specifications Table 1 updates the power specifications listed in false errors. Power Specifications Hardware Type B Connection PDU System - Model BMX01 (Dell PowerEdge M1000e) Rating 200-240VAC, 30A, 3-Phase, 50/60Hz 200-240VAC, 45A, Single Phase, 50/60Hz 200-240VAC, 30A, 50/60Hz... an encryption application, you can access the encrypted files on a blade because this recovery key. Be sure to your Hardware Owner's Manual. NOTE: Do not change the system configuration while running system diagnostics on your Getting Started Guide and Product Information Guide. If you...
...System Power Specifications Table 1 updates the power specifications listed in false errors. Power Specifications Hardware Type B Connection PDU System - Model BMX01 (Dell PowerEdge M1000e) Rating 200-240VAC, 30A, 3-Phase, 50/60Hz 200-240VAC, 45A, Single Phase, 50/60Hz 200-240VAC, 30A, 50/60Hz... an encryption application, you can access the encrypted files on a blade because this recovery key. Be sure to your Hardware Owner's Manual. NOTE: Do not change the system configuration while running system diagnostics on your Getting Started Guide and Product Information Guide. If you...
Information Update - M605, M600
Page 2
... Unsupported processor(s) installed. See "Processors" on page 113. Replace the processor(s) with a supported version. Model 10G-TOM (Dell PowerEdge M600) Rating 12VDC, 33.33A 12VDC, 35A Blade Messages Table 2 updates the following blade messages listed in your Hardware Owner's Manual: • "This system does not support processors greater than 95W." Model 10G-MAG...
... Unsupported processor(s) installed. See "Processors" on page 113. Replace the processor(s) with a supported version. Model 10G-TOM (Dell PowerEdge M600) Rating 12VDC, 33.33A 12VDC, 35A Blade Messages Table 2 updates the following blade messages listed in your Hardware Owner's Manual: • "This system does not support processors greater than 95W." Model 10G-MAG...
Information Update - Processor Installation
Page 3
... 30 seconds for the heat sink to loosen from AC power, press and hold the power button for 3 seconds to upgrading your Hardware Owner's Manual for some time after the system has been powered down (thermal grease side facing up). WARNING: The heat sink and processor are authorized to remove...1 Prior to fully drain the system of the system. 3 Open the system. See your system, download the latest system BIOS version from support.dell.com and follow the instructions included in the compressed download file to install the update on components in the interior of stored power prior to...
... 30 seconds for the heat sink to loosen from AC power, press and hold the power button for 3 seconds to upgrading your Hardware Owner's Manual for some time after the system has been powered down (thermal grease side facing up). WARNING: The heat sink and processor are authorized to remove...1 Prior to fully drain the system of the system. 3 Open the system. See your system, download the latest system BIOS version from support.dell.com and follow the instructions included in the compressed download file to install the update on components in the interior of stored power prior to...
Information Update - Processor Installation
Page 4
... from the socket. See Figure 1-2. 4 Processor Installation Be aware that the release lever can spring up suddenly if not firmly grasped. 9 Position your Hardware Owner's Manual for a system-specific illustration. Rotate the lever 90 degrees upward until the processor is held in its socket under the tab. CAUTION: The processor is...
... from the socket. See Figure 1-2. 4 Processor Installation Be aware that the release lever can spring up suddenly if not firmly grasped. 9 Position your Hardware Owner's Manual for a system-specific illustration. Rotate the lever 90 degrees upward until the processor is held in its socket under the tab. CAUTION: The processor is...
Information Update - Processor Installation
Page 9
...Installation 9 See your processor kit and apply all of the thermal grease in the Hardware Owner's Manual for a systemspecific illustration. See "Installing the Cooling Shroud" in the Hardware Owner's Manual. 14 Reconnect your system and peripherals to their electrical outlets, and turn on the processor. ... to verify that the processor information matches the new system configuration. See "Entering the System Setup Program" in the Hardware Owner's Manual. 16 Run the system diagnostics to enter the System Setup program, and check that the new processor operates correctly. 17 See "...
...Installation 9 See your processor kit and apply all of the thermal grease in the Hardware Owner's Manual for a systemspecific illustration. See "Installing the Cooling Shroud" in the Hardware Owner's Manual. 14 Reconnect your system and peripherals to their electrical outlets, and turn on the processor. ... to verify that the processor information matches the new system configuration. See "Entering the System Setup Program" in the Hardware Owner's Manual. 16 Run the system diagnostics to enter the System Setup program, and check that the new processor operates correctly. 17 See "...
Getting Started Guide
Page 12
...included with the system. • The Configuration Guide provides information on support.dell.com/manuals and read the updates first because they often supersede information in other documents. Dell™ offers comprehensive hardware training and certification. This service may not be ...your system into a rack. • The Hardware Owner's Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. • Dell systems management application documentation provides information about installing and using the...
...included with the system. • The Configuration Guide provides information on support.dell.com/manuals and read the updates first because they often supersede information in other documents. Dell™ offers comprehensive hardware training and certification. This service may not be ...your system into a rack. • The Hardware Owner's Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. • Dell systems management application documentation provides information about installing and using the...
Getting Started Guide
Page 22
.... Environmental NOTE: For additional information about the I /O Module Specifications For information about environmental measurements for specific system configurations, see the Dell PowerEdge M1000e Systems Configuration Guide at 10-250 Hz for 15 min Maximum shock Operating One shock pulse in the positive z axis (one pulse...gradation of 10% per 300 m (985 ft) above 900 m (2955 ft). The system is not for 15 min Storage 1.54 Grms at support.dell.com/manuals. Temperature Operating 10° to 35°C (50° to 35,000 ft) 20 Getting Started With Your System
.... Environmental NOTE: For additional information about the I /O Module Specifications For information about environmental measurements for specific system configurations, see the Dell PowerEdge M1000e Systems Configuration Guide at 10-250 Hz for 15 min Maximum shock Operating One shock pulse in the positive z axis (one pulse...gradation of 10% per 300 m (985 ft) above 900 m (2955 ft). The system is not for 15 min Storage 1.54 Grms at support.dell.com/manuals. Temperature Operating 10° to 35°C (50° to 35,000 ft) 20 Getting Started With Your System
Dell PowerEdge M1000e Configuration Guide
Page 27
... enclosure. See Figure 1-4. Network Information If your network uses static addressing, you have configured the switch modules, as the system does not operate at support.dell.com/manuals. 2 Initial System Configuration Before You Begin Power Requirements CAUTION: The enclosure power supplies must be connected to a Type B or permanently-connected PDU and not...
... enclosure. See Figure 1-4. Network Information If your network uses static addressing, you have configured the switch modules, as the system does not operate at support.dell.com/manuals. 2 Initial System Configuration Before You Begin Power Requirements CAUTION: The enclosure power supplies must be connected to a Type B or permanently-connected PDU and not...
Dell PowerEdge M1000e Configuration Guide
Page 37
... interface. The firmware transfer process begins and the status displays the message Firmware Update in . 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com/manuals for complete instructions on how to continue. Updating the CMC Firmware Using the Web-Based Interface 1 Log in to the CMC...
... interface. The firmware transfer process begins and the status displays the message Firmware Update in . 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com/manuals for complete instructions on how to continue. Updating the CMC Firmware Using the Web-Based Interface 1 Log in to the CMC...
Dell PowerEdge M1000e Configuration Guide
Page 49
... C2 See Figure 3-2 and Figure 3-3 to identify the version of the CMC web-based interface. Table 3-1. Configuring the I /O module installation guidelines, see your Hardware Owner's Manual. Identifying Midplane Version The version of the midplane installed in the enclosure is displayed in the Midplane Revision field under the Summary tab of the...
... C2 See Figure 3-2 and Figure 3-3 to identify the version of the CMC web-based interface. Table 3-1. Configuring the I /O module installation guidelines, see your Hardware Owner's Manual. Identifying Midplane Version The version of the midplane installed in the enclosure is displayed in the Midplane Revision field under the Summary tab of the...