Dell PowerEdge R720 and R720xd Owner's Manual
Page 135
... to run from the Dell Lifecycle Controller. Running The Embedded System Diagnostics The embedded system diagnostics program is to provide extra information about using diagnostics, see the Dell Online PowerEdge Diagnostics User's Guide under Software → Serviceability Tools, at support.dell.com/manuals. 5 Using...embedded system diagnostics provides a set of diagnostic programs or test modules, allows you to select System Utilities → Launch Dell Diagnostics . 135 For information about the failed device(s) • View status messages that inform you if tests are ...
... to run from the Dell Lifecycle Controller. Running The Embedded System Diagnostics The embedded system diagnostics program is to provide extra information about using diagnostics, see the Dell Online PowerEdge Diagnostics User's Guide under Software → Serviceability Tools, at support.dell.com/manuals. 5 Using...embedded system diagnostics provides a set of diagnostic programs or test modules, allows you to select System Utilities → Launch Dell Diagnostics . 135 For information about the failed device(s) • View status messages that inform you if tests are ...
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 3
System reboots to update .......... 17 Figure 13. BIOS Update File Explorer 16 Figure 12. Lifecycle Controller screen after pressing F10 during POST 18 Figure 14. Updating BIOS on Dell 12G PowerEdge Servers Contents Introduction ...5 1:1 Updates...5 BIOS DUP (Dell Update Package) from the Operating System (OS 5 Windows DUP ...5 Linux DUP ...9 DOS-based BIOS Flash Utility 10 UEFI...
System reboots to update .......... 17 Figure 13. BIOS Update File Explorer 16 Figure 12. Lifecycle Controller screen after pressing F10 during POST 18 Figure 14. Updating BIOS on Dell 12G PowerEdge Servers Contents Introduction ...5 1:1 Updates...5 BIOS DUP (Dell Update Package) from the Operating System (OS 5 Windows DUP ...5 Linux DUP ...9 DOS-based BIOS Flash Utility 10 UEFI...
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 5
...and environment. Executing the BIOS DUP (Dell Update Package) from the operating system (OS) Using the DOS-based BIOS flash utility Using the UEFI-based BIOS flash utility Using the Lifecycle Controller Platform Update option (F10) Using the... WSMAN-based 1:Many Remote Update method (Remote Enablement) 1:1 Updates BIOS DUP (Dell Update Package) from the Operating System (OS) Windows DUP Installation steps: 1. Customers can use any of the following methods, based on Dell 12G PowerEdge...
...and environment. Executing the BIOS DUP (Dell Update Package) from the operating system (OS) Using the DOS-based BIOS flash utility Using the UEFI-based BIOS flash utility Using the Lifecycle Controller Platform Update option (F10) Using the... WSMAN-based 1:Many Remote Update method (Remote Enablement) 1:1 Updates BIOS DUP (Dell Update Package) from the Operating System (OS) Windows DUP Installation steps: 1. Customers can use any of the following methods, based on Dell 12G PowerEdge...
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 7
The system will reboot and launch Lifecycle Controller (Figure 3). 7 Updating BIOS on Dell 12G PowerEdge Servers Figure 2. After DUP installation, a system reboot is required for the update to be staged 5.
The system will reboot and launch Lifecycle Controller (Figure 3). 7 Updating BIOS on Dell 12G PowerEdge Servers Figure 2. After DUP installation, a system reboot is required for the update to be staged 5.
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 8
After the BIOS is updated, a system reboot will invoke the BIOS update (Figure 4). This may take place and boot back to Lifecycle Controller 6. System reboots to the host operating system. 8 The Lifecycle Controller will automatically take a few minutes. Updating BIOS on Dell 12G PowerEdge Servers Figure 3.
After the BIOS is updated, a system reboot will invoke the BIOS update (Figure 4). This may take place and boot back to Lifecycle Controller 6. System reboots to the host operating system. 8 The Lifecycle Controller will automatically take a few minutes. Updating BIOS on Dell 12G PowerEdge Servers Figure 3.
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 9
Run the update by executing the "./PER710_BIOS_LX_6.0.7.BIN" command from the shell (Figure 5). 9 Read over the release information presented by executing "./PER710_BIOS_LX_6.0.7.BIN" from the shell. 2. Updating BIOS on Dell 12G PowerEdge Servers Figure 4. The BIOS update inside Lifecycle Controller Linux DUP Installation steps: 1.
Run the update by executing the "./PER710_BIOS_LX_6.0.7.BIN" command from the shell (Figure 5). 9 Read over the release information presented by executing "./PER710_BIOS_LX_6.0.7.BIN" from the shell. 2. Updating BIOS on Dell 12G PowerEdge Servers Figure 4. The BIOS update inside Lifecycle Controller Linux DUP Installation steps: 1.
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 10
... to perform the update. 4. Follow the remaining prompts to DOS-recognizable format (8.3). The Lifecycle Controller will reboot and launch Lifecycle Controller (Figure 3). 5. DOS-based BIOS Flash Utility The DOS or DRMK (Dell Real Mode Kernel)-based BIOS flash utility for each platform can also be truncated to ... the file. 2. Browse to the location where you must have DOS bootable media, such as a USB key. For more information on Dell 12G PowerEdge Servers Figure 5. To update the BIOS using this utility, perform the following steps: 1. Linux DUP 3. Updating BIOS on the 8.3 format...
... to perform the update. 4. Follow the remaining prompts to DOS-recognizable format (8.3). The Lifecycle Controller will reboot and launch Lifecycle Controller (Figure 3). 5. DOS-based BIOS Flash Utility The DOS or DRMK (Dell Real Mode Kernel)-based BIOS flash utility for each platform can also be truncated to ... the file. 2. Browse to the location where you must have DOS bootable media, such as a USB key. For more information on Dell 12G PowerEdge Servers Figure 5. To update the BIOS using this utility, perform the following steps: 1. Linux DUP 3. Updating BIOS on the 8.3 format...
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 17
... of available updates, and select the required updates, downloads, and apply the updates. Updating BIOS on Dell 12G PowerEdge Servers Figure 12. To update the BIOS using Lifecycle Controller, perform the following steps. 1. In this document we use the Platform Update wizard to flash the BIOS...(Figure 13). 17 Press F10 during POST. Plug the USB into the host. 2. Lifecycle Controller will launch when you select the file and press Enter. Update BIOS via Lifecycle Controller (F10) Lifecycle Controller provides a Platform Update wizard that can use the local USB device as well. You can...
... of available updates, and select the required updates, downloads, and apply the updates. Updating BIOS on Dell 12G PowerEdge Servers Figure 12. To update the BIOS using Lifecycle Controller, perform the following steps. 1. In this document we use the Platform Update wizard to flash the BIOS...(Figure 13). 17 Press F10 during POST. Plug the USB into the host. 2. Lifecycle Controller will launch when you select the file and press Enter. Update BIOS via Lifecycle Controller (F10) Lifecycle Controller provides a Platform Update wizard that can use the local USB device as well. You can...
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 18
Platform Update screen 2. Select Local Drive (Figure 15). 18 Click on Dell 12G PowerEdge Servers Figure 13. Figure 14. Updating BIOS on Platform Update Launch Platform Update (Figure 14). Lifecycle Controller screen after pressing F10 during POST 1.
Platform Update screen 2. Select Local Drive (Figure 15). 18 Click on Dell 12G PowerEdge Servers Figure 13. Figure 14. Updating BIOS on Platform Update Launch Platform Update (Figure 14). Lifecycle Controller screen after pressing F10 during POST 1.
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 23
Updating BIOS on Dell 12G PowerEdge Servers A sample output: OPTION Component Status Comp ID VersionType 1(update) FRMW Installed 26018 0.12 BP12G+ 0:2 2(update) FRMW Installed 68138 D505... Supply.Slot.1 8(update) FRMW Controller Installed 25227 1.00.00 Integrated Dell Remote Access 9(rollback) FRMW Controller Available 25227 1.00.00 Integrated Dell Remote Access 10(update) APAC Diagnostics Utility Installed 25806 4216.1 Dell Enterprise UEFI Diagnostics 11(update) APAC 1.0.0.3551, X69 Installed 28897 1.0.0.3551 Dell Lifecycle Controller 2, 12(update) FRMW Installed ...
Updating BIOS on Dell 12G PowerEdge Servers A sample output: OPTION Component Status Comp ID VersionType 1(update) FRMW Installed 26018 0.12 BP12G+ 0:2 2(update) FRMW Installed 68138 D505... Supply.Slot.1 8(update) FRMW Controller Installed 25227 1.00.00 Integrated Dell Remote Access 9(rollback) FRMW Controller Available 25227 1.00.00 Integrated Dell Remote Access 10(update) APAC Diagnostics Utility Installed 25806 4216.1 Dell Enterprise UEFI Diagnostics 11(update) APAC 1.0.0.3551, X69 Installed 28897 1.0.0.3551 Dell Lifecycle Controller 2, 12(update) FRMW Installed ...
Updating BIOS on Dell 12th-Generation PowerEdge Servers
Page 27
...accurate by checking the new version from the previous step. Once the specified start time is reached, the host reboots and launches Lifecycle Controller to verify the update by comparing it prompts for the following is a sample output of the source URI. Monitor the Update ...user name. bios updating to monitor the update: fw_poll.py Run fw_poll.py -h for bios update (0) exit out 27 Updating BIOS on Dell 12G PowerEdge Servers A sample output of a failed command: The command failed with error code: CMPI_RC_ERR_INVALID_PARAMETER If the command fails, verify that it is ...
...accurate by checking the new version from the previous step. Once the specified start time is reached, the host reboots and launches Lifecycle Controller to verify the update by comparing it prompts for the following is a sample output of the source URI. Monitor the Update ...user name. bios updating to monitor the update: fw_poll.py Run fw_poll.py -h for bios update (0) exit out 27 Updating BIOS on Dell 12G PowerEdge Servers A sample output of a failed command: The command failed with error code: CMPI_RC_ERR_INVALID_PARAMETER If the command fails, verify that it is ...