EMC Installation and Service Manual
Page 24
... selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with up to www.dell.com/support/home/us/en/04/ Drivers/SupportedOS/poweredge-c4140 PSU specifications The Dell EMC PowerEdge C4140 system supports the following AC power supply units (PSU): Table 8. Processor specifications The PowerEdge C4140 system supports two 2nd Generation Intel Xeon Scalable processors...
... selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with up to www.dell.com/support/home/us/en/04/ Drivers/SupportedOS/poweredge-c4140 PSU specifications The Dell EMC PowerEdge C4140 system supports the following AC power supply units (PSU): Table 8. Processor specifications The PowerEdge C4140 system supports two 2nd Generation Intel Xeon Scalable processors...
EMC Installation and Service Manual
Page 98
... above the maximum temperature limit or with a faulty fan. • All GPUs must be of the GPUs will cause operational issues to the high power consumption of GPUs: • Four PCIe GPUs supported with the GPU switch board or system board. • Four SXM2 GPUs supported with the NVLink board...cooling when one or more GPU cards are the high-level steps that the system detects the USB memory key. Graphics processing unit The Dell EMC PowerEdge C4140 supports two form factors of GPUs, the ambient system inlet temperature is restricted to 25°C to enter System Setup and verify that ...
... above the maximum temperature limit or with a faulty fan. • All GPUs must be of the GPUs will cause operational issues to the high power consumption of GPUs: • Four PCIe GPUs supported with the GPU switch board or system board. • Four SXM2 GPUs supported with the NVLink board...cooling when one or more GPU cards are the high-level steps that the system detects the USB memory key. Graphics processing unit The Dell EMC PowerEdge C4140 supports two form factors of GPUs, the ambient system inlet temperature is restricted to 25°C to enter System Setup and verify that ...
EMC Technical Specifications
Page 7
... processors with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA. NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with up to www.dell.com/support/home/us/en/04/ Drivers/SupportedOS/poweredge-c4140 PSU specifications The Dell EMC PowerEdge C4140 system supports the following AC power supply units (PSU...
... processors with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA. NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with up to www.dell.com/support/home/us/en/04/ Drivers/SupportedOS/poweredge-c4140 PSU specifications The Dell EMC PowerEdge C4140 system supports the following AC power supply units (PSU...
EMC Systems Management Overview Guide Version 20.0
Page 8
... control power consumption to the systems in QR code for ease-of energy consumption throughout a data center. To automate the creation of baseline repositories, DRM provides advanced integration capabilities with the 12th generation or later versions of the PowerEdge servers,... Systems Management Product Overview Dell EMC Repository Manager can also assign maximum power to the servers that are : • Measure and manage power consumption and monitors thermal readings-OME Power Manager provides greater insight into custom catalogs that reduce the power consumption when the demand on...
... control power consumption to the systems in QR code for ease-of energy consumption throughout a data center. To automate the creation of baseline repositories, DRM provides advanced integration capabilities with the 12th generation or later versions of the PowerEdge servers,... Systems Management Product Overview Dell EMC Repository Manager can also assign maximum power to the servers that are : • Measure and manage power consumption and monitors thermal readings-OME Power Manager provides greater insight into custom catalogs that reduce the power consumption when the demand on...
EMC Systems Management Overview Guide Version 20.0
Page 15
... compliance check for Microsoft System Center Virtual Machine Manager Dell EMC server PRO Management Pack integrates PowerEdge server knowledge on the IT Administrator defined standards to ...streamlined management of PowerEdge servers supported by using the same role-based access control model as a Golden Configuration, based on temperature, memory, and power supplies with Microsoft...consumption. • Deploying OS and hypervisor by Microsoft Windows Server and Hyper-V, Storage Spaces Direct Ready Nodes for VMware vCenter (OMIVV) allows you to monitor, provision, and manage PowerEdge...
... compliance check for Microsoft System Center Virtual Machine Manager Dell EMC server PRO Management Pack integrates PowerEdge server knowledge on the IT Administrator defined standards to ...streamlined management of PowerEdge servers supported by using the same role-based access control model as a Golden Configuration, based on temperature, memory, and power supplies with Microsoft...consumption. • Deploying OS and hypervisor by Microsoft Windows Server and Hyper-V, Storage Spaces Direct Ready Nodes for VMware vCenter (OMIVV) allows you to monitor, provision, and manage PowerEdge...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 197
... • 1 (ON) • 0 (OFF) Default 0 cfgServerPowerAllocation (Read Only) Table 265. Details of cfgServerActualPowerConsumption Description Represents the power consumption by the server at the current time. Details of cfgServerPowerCapEnable Description Enables or disables the user specified power budget threshold. Legal Values Not applicable Default cfgServerPowerCapEnable (Read or Write) Table 267. Details of up to...
... • 1 (ON) • 0 (OFF) Default 0 cfgServerPowerAllocation (Read Only) Table 265. Details of cfgServerActualPowerConsumption Description Represents the power consumption by the server at the current time. Details of cfgServerPowerCapEnable Description Enables or disables the user specified power budget threshold. Legal Values Not applicable Default cfgServerPowerCapEnable (Read or Write) Table 267. Details of up to...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 198
...) Table 273. Legal Values A string of cfgServerMaxPowerCapacity Description Represents the maximum server power capacity based on the current component consumption. Details of cfgServerPeakPowerConsumptionTimestamp Description Specifies time when the maximum power consumption was recorded. Details of cfgServerPeakPowerConsumption Description Represents the server's maximum power consumption until the current time. Legal Values None 198 iDRAC Property Database Group and...
...) Table 273. Legal Values A string of cfgServerMaxPowerCapacity Description Represents the maximum server power capacity based on the current component consumption. Details of cfgServerPeakPowerConsumptionTimestamp Description Specifies time when the maximum power consumption was recorded. Details of cfgServerPeakPowerConsumption Description Represents the server's maximum power consumption until the current time. Legal Values None 198 iDRAC Property Database Group and...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 203
...is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. Legal Values Not applicable Default Current power consumption. Time in the format: DD MM Date HH:MM:SS YYYY where, • DD = Day of the week • MM... = hour • MM = Minutes • SS = Seconds Default Timestamp of cfgServerPowerInstHeadroom Description Displays the difference between the available power and the current power consumption. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. iDRAC Property ...
...is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. Legal Values Not applicable Default Current power consumption. Time in the format: DD MM Date HH:MM:SS YYYY where, • DD = Day of the week • MM... = hour • MM = Minutes • SS = Seconds Default Timestamp of cfgServerPowerInstHeadroom Description Displays the difference between the available power and the current power consumption. This object is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers. iDRAC Property ...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 204
... (Read Only) Table 296. Details of cfgServerCumulativePowerConsumptionTimeStamp Description Displays the timestamp of cfgServerPeakAmperage Description Displays the current peak power consumption. Time in the format: DD MM Date HH:MM:SS YYYY where, • DD = Day of ... Property Database Group and Object Descriptions Legal Values A string of the current peak power consumption. Legal Values Not applicable Default Current peak power consumption. Details of cfgServerPeakAmperageTimeStamp Description Displays the timestamp of up to 32 characters. Time...
... (Read Only) Table 296. Details of cfgServerCumulativePowerConsumptionTimeStamp Description Displays the timestamp of cfgServerPeakAmperage Description Displays the current peak power consumption. Time in the format: DD MM Date HH:MM:SS YYYY where, • DD = Day of ... Property Database Group and Object Descriptions Legal Values A string of the current peak power consumption. Legal Values Not applicable Default Current peak power consumption. Details of cfgServerPeakAmperageTimeStamp Description Displays the timestamp of up to 32 characters. Time...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 205
...on Rack and Tower Servers and not for iDRAC Enterprise on Rack and Tower Servers. You must have the Administrator privileges to the power supplies. Default 0: For platforms that do not support PCIe cards. 100 W - 500 W: For platforms that support PCIe cards... group. cfgServerPowerSupply This group contains information related to modify the value for iDRAC on Blade Servers. Details of the cumulative power consumption. Details of up to the PCIe cards. Legal Values 1 Default None cfgServerPowerPCIeAllocation (Read or Write) Table 299. cfgServerPowerSupplyCurrentDraw...
...on Rack and Tower Servers and not for iDRAC Enterprise on Rack and Tower Servers. You must have the Administrator privileges to the power supplies. Default 0: For platforms that do not support PCIe cards. 100 W - 500 W: For platforms that support PCIe cards... group. cfgServerPowerSupply This group contains information related to modify the value for iDRAC on Blade Servers. Details of the cumulative power consumption. Details of up to the PCIe cards. Legal Values 1 Default None cfgServerPowerPCIeAllocation (Read or Write) Table 299. cfgServerPowerSupplyCurrentDraw...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 253
...Values: 1-65535 Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.MinThreshold (Read Only) Table 427. Details of the device. Legal Values Values: 1-65535 Default Value Not ... throttle the device. Details of System.Power.Cap.MinThreshold Description Because it is based on the current component inventory, it is based on the current component inventory, it is the lowest calculated power consumption of System.Power.Redundancypolicy Description Legal Values Selects the redundancy...
...Values: 1-65535 Default Value Not Applicable Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Cap.MinThreshold (Read Only) Table 427. Details of the device. Legal Values Values: 1-65535 Default Value Not ... throttle the device. Details of System.Power.Cap.MinThreshold Description Because it is based on the current component inventory, it is based on the current component inventory, it is the lowest calculated power consumption of System.Power.Redundancypolicy Description Legal Values Selects the redundancy...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 254
...if one PSU input circuit stops functioning, provided the PSUs are connected to 1. Details of System.Power.EnergyConsumption.Clear Description Clears the cumulative power consumption timestamps. 254 Database Objects With Get and Set Commands PSU Redundant - This is set to ...Required Dependency • 0 - Legal Values Values: 1-65535 Default Value Cumulative power consumption Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.EnergyConsumption.Clear (Read or Write) Table 432. N/A Login and configure iDRAC iDRAC...
...if one PSU input circuit stops functioning, provided the PSUs are connected to 1. Details of System.Power.EnergyConsumption.Clear Description Clears the cumulative power consumption timestamps. 254 Database Objects With Get and Set Commands PSU Redundant - This is set to ...Required Dependency • 0 - Legal Values Values: 1-65535 Default Value Cumulative power consumption Write Privilege Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.EnergyConsumption.Clear (Read or Write) Table 432. N/A Login and configure iDRAC iDRAC...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 255
...) Table 435. Details of the cumulative power consumption. Details of System.Power.EnergyConsumption.StarttimeStamp Description Displays the Timestamp of System.Power.Hotspare.Enable Description Enables hot-spare functionality for the primary PSU selection. For more information about hot-spare, see the iDRAC User's Guide available at www.dell.com/esmmanuals. Write Privilege Not Applicable License...
...) Table 435. Details of the cumulative power consumption. Details of System.Power.EnergyConsumption.StarttimeStamp Description Displays the Timestamp of System.Power.Hotspare.Enable Description Enables hot-spare functionality for the primary PSU selection. For more information about hot-spare, see the iDRAC User's Guide available at www.dell.com/esmmanuals. Write Privilege Not Applicable License...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 256
... Applicable Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps (Read Only) Table 436. Default Value Current peak power consumption Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps.TimeStamp (Read Only) Table 437. NOTE: This object is not applicable...
... Applicable Configure iDRAC License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps (Read Only) Table 436. Default Value Current peak power consumption Write Privilege Not Applicable License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.Amps.TimeStamp (Read Only) Table 437. NOTE: This object is not applicable...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 258
... characters Default Value Timestamp of maximum power consumption. 258 Database Objects With Get and Set Commands Legal Values Values: 1-65535 Default Value Peak power consumption of System.Power.Max. License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastWeek (Read Only) Table 443. Details of System.Power.Max.Power.Timestamp Description Displays time of the...
... characters Default Value Timestamp of maximum power consumption. 258 Database Objects With Get and Set Commands Legal Values Values: 1-65535 Default Value Peak power consumption of System.Power.Max. License Required iDRAC Express or iDRAC Enterprise Dependency None System.Power.Max.LastWeek (Read Only) Table 443. Details of System.Power.Max.Power.Timestamp Description Displays time of the...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 259
... during the last day. Legal Values Values: 1-65535 Default Value Minimum power value during the last day. Details of System.Power.Min.LastDay Description Displays the minimum power during the last day. Details of System.Power.Max.PowerClear Description Clears the Maximum Power Consumption timestamps. Legal Values 1 - Legal Values String of up to 254 ASCII characters...
... during the last day. Legal Values Values: 1-65535 Default Value Minimum power value during the last day. Details of System.Power.Min.LastDay Description Displays the minimum power during the last day. Details of System.Power.Max.PowerClear Description Clears the Maximum Power Consumption timestamps. Legal Values 1 - Legal Values String of up to 254 ASCII characters...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 262
... Description Retrieves the redundancy state for Rack and Tower server. Legal Values • 0 - Legal Values String of System.Power.Supply.CurrentDraw Description Displays the instantaneous current consumption in this group are less than four power supplies on Rack and Tower servers. None Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable...
... Description Retrieves the redundancy state for Rack and Tower server. Legal Values • 0 - Legal Values String of System.Power.Supply.CurrentDraw Description Displays the instantaneous current consumption in this group are less than four power supplies on Rack and Tower servers. None Write Privilege Not Applicable License Required Not Applicable Dependency Not Applicable...
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 269
...Dependency None System.Serverpwr.PowerCapSetting Table 481. Disabled. • 1 - Details of System.Serverpwr.PowerCapSetting subcommand Description Enables or Disables setting the Power Cap value. Legal Values Integral values from 0 to system. Details of system.storage.availableSpareAlertThreshold Description Displays the system level user configured threshold value... Dependency None Database Objects With Get and Set Commands 269 Details of System.Serverpwr.PowerCapValue subcommand Description Indicates maximum power consumption limit in Watts. Legal Values • 0 -
...Dependency None System.Serverpwr.PowerCapSetting Table 481. Disabled. • 1 - Details of System.Serverpwr.PowerCapSetting subcommand Description Enables or Disables setting the Power Cap value. Legal Values Integral values from 0 to system. Details of system.storage.availableSpareAlertThreshold Description Displays the system level user configured threshold value... Dependency None Database Objects With Get and Set Commands 269 Details of System.Serverpwr.PowerCapValue subcommand Description Indicates maximum power consumption limit in Watts. Legal Values • 0 -
iDRAC9 with Lifecycle Controller Version 3.30.30.30 RACADM CLI Guide
Page 407
... BIOS.ProcSettings.PerfMonitorDevices (Read or Write) Table 914. The details of BIOS.ProcSettings.LogicalProc attribute Description To enable report all logical processors and to reduce power consumption. • Enabled • Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.LogicalProc (Read...
... BIOS.ProcSettings.PerfMonitorDevices (Read or Write) Table 914. The details of BIOS.ProcSettings.LogicalProc attribute Description To enable report all logical processors and to reduce power consumption. • Enabled • Disabled Default Value Not Applicable Write Privilege Server Control License Required iDRAC Express or iDRAC Enterprise Dependency None BIOS.ProcSettings.LogicalProc (Read...