Information Update
Page 5
... team consists of up of server modules • Server-module board DIP switch settings • Console redirection information • Microsoft® Windows® 2000 Advanced Server operating system information • System diagnostics-NIC entry in your system. NIC Teaming Restrictions Each server module (blade) in PCI device list ...dual-port Gb Ethernet daughter card, for a total of the two integrated Broadcom Gb Ethernet ports. See support.dell.com for information on processor availability and upgrade options for your system provides two integrated Broadcom Gb Ethernet ports as...
... team consists of up of server modules • Server-module board DIP switch settings • Console redirection information • Microsoft® Windows® 2000 Advanced Server operating system information • System diagnostics-NIC entry in your system. NIC Teaming Restrictions Each server module (blade) in PCI device list ...dual-port Gb Ethernet daughter card, for a total of the two integrated Broadcom Gb Ethernet ports. See support.dell.com for information on processor availability and upgrade options for your system provides two integrated Broadcom Gb Ethernet ports as...
Information Update
Page 6
...1-1. This is removed from the system, all server modules (blades) in the system will indicate if throttling of Server Modules If a power supply or fan module is normal behavior for these cards, and supersedes Table 1-11 in the server module (blade). The enclosure's System Event Log (SEL) will... activity. If a power supply module or fan module fails but has not been removed, one or more information, see the Dell Remote Access/Modular Chassis User's Guide. 4 Information Update Throttling reduces the power consumption of the server modules by approximately 50%. Cards currently ...
...1-1. This is removed from the system, all server modules (blades) in the system will indicate if throttling of Server Modules If a power supply or fan module is normal behavior for these cards, and supersedes Table 1-11 in the server module (blade). The enclosure's System Event Log (SEL) will... activity. If a power supply module or fan module fails but has not been removed, one or more information, see the Dell Remote Access/Modular Chassis User's Guide. 4 Information Update Throttling reduces the power consumption of the server modules by approximately 50%. Cards currently ...
Configuration Guide
Page 5
...Additional Integrated Mirroring Guidelines 10 Connecting a USB Drive, Keyboard, and Mouse to the Server Module Front Panel 10 Installing an Operating System 10 Configuring the DRAC/MC Module 11 DRAC/MC Module Features 11 DRAC/MC Configuration Interface Options 12 Web-Based Interface 13 Serial or Telnet... the DRAC/MC Serial Console to the Ethernet Switch Module 19 Updating the DRAC/MC Module Firmware 19 Integrating the System Into the Network 22 Updating the PowerConnect Switch Module Firmware 27 Configuring the Cisco Catalyst Blade Switch 3030 29 Configuring the Cisco Switch Using a ...
...Additional Integrated Mirroring Guidelines 10 Connecting a USB Drive, Keyboard, and Mouse to the Server Module Front Panel 10 Installing an Operating System 10 Configuring the DRAC/MC Module 11 DRAC/MC Module Features 11 DRAC/MC Configuration Interface Options 12 Web-Based Interface 13 Serial or Telnet... the DRAC/MC Serial Console to the Ethernet Switch Module 19 Updating the DRAC/MC Module Firmware 19 Integrating the System Into the Network 22 Updating the PowerConnect Switch Module Firmware 27 Configuring the Cisco Catalyst Blade Switch 3030 29 Configuring the Cisco Switch Using a ...
Configuration Guide
Page 7
... This guide provides information on page 6. See "Other Documents You May Need" on configuring your system and the server modules in the enclosure. Each server module functions as "blades"). Additional information is inserted into an enclosure that supports power supplies, fan modules, a management module (Dell™ Remote Access Controller/Modular Chassis [DRAC/MC]), a keyboard/video/mouse (KVM) switch...
... This guide provides information on page 6. See "Other Documents You May Need" on configuring your system and the server modules in the enclosure. Each server module functions as "blades"). Additional information is inserted into an enclosure that supports power supplies, fan modules, a management module (Dell™ Remote Access Controller/Modular Chassis [DRAC/MC]), a keyboard/video/mouse (KVM) switch...
Configuration Guide
Page 11
... page 29. See "Configuring the PowerConnect 5316M Ethernet Switch Module" on page 25 or "Configuring the Cisco Catalyst Blade Switch 3030" on page 17. If an operating system is preinstalled, you ordered your network, the server will permit configuration using the network. To add a disk...before installing an operating system on the server module. See the Dell Remote Access Controller/Modular Chassis User's Guide and the switch module's documentation for instructions on the DRAC/MC module. See"Redirecting the DRAC/MC Serial Console to the Ethernet Switch Module" on page 19. 10 Assign ...
... page 29. See "Configuring the PowerConnect 5316M Ethernet Switch Module" on page 25 or "Configuring the Cisco Catalyst Blade Switch 3030" on page 17. If an operating system is preinstalled, you ordered your network, the server will permit configuration using the network. To add a disk...before installing an operating system on the server module. See the Dell Remote Access Controller/Modular Chassis User's Guide and the switch module's documentation for instructions on the DRAC/MC module. See"Redirecting the DRAC/MC Serial Console to the Ethernet Switch Module" on page 19. 10 Assign ...
Configuration Guide
Page 27
...the embedded Ethernet controller on the server modules and operate at 100 Mbps and half duplex. (Note that shipped with the module or on support.dell.com. General System Configuration 25 Configuring a Port on a Cisco Catalyst Blade Switch 3030 Switch Module The following command to enter ...Configuring the PowerConnect 5316M Ethernet Switch Module The PowerConnect 5316M Ethernet switch module is an example of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS-Based Switches engineering brief on the switch module's page on www.dell.com. For detailed information on ...
...the embedded Ethernet controller on the server modules and operate at 100 Mbps and half duplex. (Note that shipped with the module or on support.dell.com. General System Configuration 25 Configuring a Port on a Cisco Catalyst Blade Switch 3030 Switch Module The following command to enter ...Configuring the PowerConnect 5316M Ethernet Switch Module The PowerConnect 5316M Ethernet switch module is an example of the Dell PowerConnect 5316M with Cisco IOS or Cisco CatOS-Based Switches engineering brief on the switch module's page on www.dell.com. For detailed information on ...
Configuration Guide
Page 31
For detailed information on the Cisco Catalyst Blade Switch 3030, see the documentation that shipped with the module or on the server module and operate at 1000 Mb only. • The external console port provides an connection for a management station, using the RJ45-to-DB9 cable ... connect to the external Ethernet network and operate at 10/100/1000 Mb. • The 10 downlinks connect to the embedded Ethernet controller on support.dell.com. General System Configuration 29 Two uplinks are 10/100/1000BASE-T ports. Do not change the switch's management interface value. 4 Click Submit to...
For detailed information on the Cisco Catalyst Blade Switch 3030, see the documentation that shipped with the module or on the server module and operate at 1000 Mb only. • The external console port provides an connection for a management station, using the RJ45-to-DB9 cable ... connect to the external Ethernet network and operate at 10/100/1000 Mb. • The 10 downlinks connect to the embedded Ethernet controller on support.dell.com. General System Configuration 29 Two uplinks are 10/100/1000BASE-T ports. Do not change the switch's management interface value. 4 Click Submit to...
Configuration Guide
Page 35
... switches, including Avocent switches, connect the KVM to ARI ports on the PowerEdge™ 1855 system is not supported by your system - NOTICE: The basic Dell™ KVM pass-though module used to connect to the switch's PS2 and video ports using the proprietary... revision installed. Figure 2-1. NOTE: The Avocent Analog KVM switch ACI port can only be used on Dell console switches, with that switch. Avocent Analog KVM Switch Module 1 2 1 ACI port 4 power indicator 3 4 2 custom connector for the two KVM switch modules supported by Dell PowerEdge 1955 server modules (blades).
... switches, including Avocent switches, connect the KVM to ARI ports on the PowerEdge™ 1855 system is not supported by your system - NOTICE: The basic Dell™ KVM pass-though module used to connect to the switch's PS2 and video ports using the proprietary... revision installed. Figure 2-1. NOTE: The Avocent Analog KVM switch ACI port can only be used on Dell console switches, with that switch. Avocent Analog KVM Switch Module 1 2 1 ACI port 4 power indicator 3 4 2 custom connector for the two KVM switch modules supported by Dell PowerEdge 1955 server modules (blades).
Configuration Guide
Page 46
Table 2-3. NOTE: You can also use the key to a server module, you will be able to access all the normal functions of servers, select the server module (blade) you would like to On. The procedure varies depending on your screen. Once you will appear. ... two cursors to match your client's cursor and the remote server's cursor, which you have connected to switch between server modules. 5 Click the Launch Viewer Application button. See "Synchronizing the Mouse Pointers" in the Dell Remote Access Controller/Modular Chassis User's Guide for specific instructions ...
Table 2-3. NOTE: You can also use the key to a server module, you will be able to access all the normal functions of servers, select the server module (blade) you would like to On. The procedure varies depending on your screen. Once you will appear. ... two cursors to match your client's cursor and the remote server's cursor, which you have connected to switch between server modules. 5 Click the Launch Viewer Application button. See "Synchronizing the Mouse Pointers" in the Dell Remote Access Controller/Modular Chassis User's Guide for specific instructions ...
Hardware Owner's Manual (PDF)
Page 10
...external USB diskette drive and an optional external USB CD drive, which you may need when setting up to ten server modules (or blades) (see Figure 1-2). System Status Features The chassis has front-panel control features including power and identification buttons and...system. Each server module functions as a system, a server module is inserted into a chassis that supports power supplies, fan modules, a management module (Dell™ Remote Access Controller/Modular Chassis [DRAC/MC]), a KVM switch module, and at all bays must be populated at least one I /O modules are shared ...
...external USB diskette drive and an optional external USB CD drive, which you may need when setting up to ten server modules (or blades) (see Figure 1-2). System Status Features The chassis has front-panel control features including power and identification buttons and...system. Each server module functions as a system, a server module is inserted into a chassis that supports power supplies, fan modules, a management module (Dell™ Remote Access Controller/Modular Chassis [DRAC/MC]), a KVM switch module, and at all bays must be populated at least one I /O modules are shared ...
Hardware Owner's Manual (PDF)
Page 16
... USB devices and video to configure the server module. NOTICE: The system supports only Dell-branded USB 1.1 or USB 2.0 drives. Different patterns are used to the server module. Table 1-2. See "Baseboard Management Controller Configuration" on the front of the server module which allows you can install server modules (blades) with SAS drives and server modules with SATA drives in each hard-drive...
... USB devices and video to configure the server module. NOTICE: The system supports only Dell-branded USB 1.1 or USB 2.0 drives. Different patterns are used to the server module. Table 1-2. See "Baseboard Management Controller Configuration" on the front of the server module which allows you can install server modules (blades) with SAS drives and server modules with SATA drives in each hard-drive...
Hardware Owner's Manual (PDF)
Page 89
... press to run the RAID configuration utility. 3 Change the degraded array properties from the server module board, reinstall it. The server module can install server modules (blades) with SAS drives and server modules with SATA drives in the same server enclosure. See "Installing a Server Module" on page 74. 9 Enter the System Setup program to rebuild the degraded array in a RAID configuration contains...
... press to run the RAID configuration utility. 3 Change the degraded array properties from the server module board, reinstall it. The server module can install server modules (blades) with SAS drives and server modules with SATA drives in the same server enclosure. See "Installing a Server Module" on page 74. 9 Enter the System Setup program to rebuild the degraded array in a RAID configuration contains...