Hardware Installation Guide
Page 11
... you to situations that can be potentially lethal or extremely hazardous to you or cause damage to you . Phillips PowerConnect B-MLXe Hardware Installation Guide xi 53-1002111-01 Command examples This document describes how to warn of the following notices and ...danger statements are made for PowerConnect B-MLXe routers, see the Brocade NetIron Configuration Guide. For complete descriptions of the parameters. Corporation Referenced trademarks and products Phillips Screw Company, ...
... you to situations that can be potentially lethal or extremely hazardous to you or cause damage to you . Phillips PowerConnect B-MLXe Hardware Installation Guide xi 53-1002111-01 Command examples This document describes how to warn of the following notices and ...danger statements are made for PowerConnect B-MLXe routers, see the Brocade NetIron Configuration Guide. For complete descriptions of the parameters. Corporation Referenced trademarks and products Phillips Screw Company, ...
Hardware Installation Guide
Page 47
... - 4 SF1 - If you must leave the slot blank installed in the Brocade NetIron Configuration Guide for information about how the redundant module works, optional software configurations, and how to remove the slot blank from Dell • An ESD wrist strap with a plug for connection to the ESD... connector on the router chassis. DANGER For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor. You can order from the module slot. PowerConnect B-MLXe Hardware Installation ...
... - 4 SF1 - If you must leave the slot blank installed in the Brocade NetIron Configuration Guide for information about how the redundant module works, optional software configurations, and how to remove the slot blank from Dell • An ESD wrist strap with a plug for connection to the ESD... connector on the router chassis. DANGER For safety reasons, the ESD wrist strap should contain a 1 megohm series resistor. You can order from the module slot. PowerConnect B-MLXe Hardware Installation ...
Hardware Installation Guide
Page 75
... you can perform, and how to manage the redundancy feature. If you install a PowerConnect B-MLXe module in another Dell router or install a module intended for another Dell router in the Brocade NetIron Configuration Guide for the router slots appear at the base of a power screwdriver ...may not function properly. TABLE 15 Module PowerConnect B-MLXe-16 module slot designations Slot number Management modules Interface modules ...
... you can perform, and how to manage the redundancy feature. If you install a PowerConnect B-MLXe module in another Dell router or install a module intended for another Dell router in the Brocade NetIron Configuration Guide for the router slots appear at the base of a power screwdriver ...may not function properly. TABLE 15 Module PowerConnect B-MLXe-16 module slot designations Slot number Management modules Interface modules ...
Hardware Installation Guide
Page 156
...Version 2 SL M2: NI-MLX-MR Management Module Active (Serial #: SA21091472, Part #: 35524-103C): Boot: Version 5.1.0T165 Copyright(c)1996-2009 Brocade Communications Systems,Inc. Compiled on Sep 16 2010 at 14:06:58 labeled as xmr05100 (6986803 bytes) from boot flash Monitor: Version 5.1.0T165 ...Bytes BRAM PPCR0: 768K entries CAM, 8192K PRAM, 2048K AGE RAM PPCR1: 768K entries CAM, 8192K PRAM, 2048K AGE RAM 144 PowerConnect B-MLXe Hardware Installation Guide 53-1002111-01 Compiled on Sep 16 2010 at 14:06:30 labeled as xmlp05100 (4950936 bytes) from code flash ...
...Version 2 SL M2: NI-MLX-MR Management Module Active (Serial #: SA21091472, Part #: 35524-103C): Boot: Version 5.1.0T165 Copyright(c)1996-2009 Brocade Communications Systems,Inc. Compiled on Sep 16 2010 at 14:06:58 labeled as xmr05100 (6986803 bytes) from boot flash Monitor: Version 5.1.0T165 ...Bytes BRAM PPCR0: 768K entries CAM, 8192K PRAM, 2048K AGE RAM PPCR1: 768K entries CAM, 8192K PRAM, 2048K AGE RAM 144 PowerConnect B-MLXe Hardware Installation Guide 53-1002111-01 Compiled on Sep 16 2010 at 14:06:30 labeled as xmlp05100 (4950936 bytes) from code flash ...
Hardware Installation Guide
Page 157
...on Sep 16 2010 at 17:55:24 labeled as xmlp05100 (4950936 bytes) from code flash IronWare: Version 5.1.0T177 Copyright(c)1996-2009 Brocade Communications Systems, Inc. You must configure the maximum ifIndex per module to 64; otherwise, the module remains in the Offline state....(c)1996-2009 Brocade Communications Systems, Inc. otherwise, the module remains in the Offline state. • If you have a new device (no previous software installed), and will be installing an NI-MLX-1Gx48-T module, you configure the maximum ifIndex per module. PowerConnect B-MLXe Hardware Installation ...
...on Sep 16 2010 at 17:55:24 labeled as xmlp05100 (4950936 bytes) from code flash IronWare: Version 5.1.0T177 Copyright(c)1996-2009 Brocade Communications Systems, Inc. You must configure the maximum ifIndex per module to 64; otherwise, the module remains in the Offline state....(c)1996-2009 Brocade Communications Systems, Inc. otherwise, the module remains in the Offline state. • If you have a new device (no previous software installed), and will be installing an NI-MLX-1Gx48-T module, you configure the maximum ifIndex per module. PowerConnect B-MLXe Hardware Installation ...
Hardware Installation Guide
Page 176
...times within an Hour The power supply will flap three times within an hour after which the failed power supply is configured. 164 PowerConnect B-MLXe Hardware Installation Guide 53-1002111-01 The default value is from 0 through 32. For Syslog messages, please refer to clear all ...or for all collected failure timestamps for the Power Supply # 1 Are you sure? (enter 'y' or 'n'): y You are numbered in the Brocade NetIron Configuration Guide. Clearing power supply failure timestamps The power-supply monitoring clear command is used to Appendix A, Using Syslog in the display. To ...
...times within an Hour The power supply will flap three times within an hour after which the failed power supply is configured. 164 PowerConnect B-MLXe Hardware Installation Guide 53-1002111-01 The default value is from 0 through 32. For Syslog messages, please refer to clear all ...or for all collected failure timestamps for the Power Supply # 1 Are you sure? (enter 'y' or 'n'): y You are numbered in the Brocade NetIron Configuration Guide. Clearing power supply failure timestamps The power-supply monitoring clear command is used to Appendix A, Using Syslog in the display. To ...