Command Line Interface Guide
Page 1165
Command Mode Privileged EXEC mode User Guidelines The copper-related commands do not apply to the stacking, CX-4, or 10GBaseT ports associated with these plug-in modules. PHY Diagnostics Commands 1165 A valid Ethernet port. console#show copper-ports tdr [interface] • ... default configuration. Example The following example displays the last TDR tests on all ports. The full syntax is 120 meters. The maximum length of the cable for the Time Domain Reflectometry (TDR) test is unit / port. Syntax show copper-ports tdr Port Result Length [meters] Date 1/g1 OK 1/g2 ...
Command Mode Privileged EXEC mode User Guidelines The copper-related commands do not apply to the stacking, CX-4, or 10GBaseT ports associated with these plug-in modules. PHY Diagnostics Commands 1165 A valid Ethernet port. console#show copper-ports tdr [interface] • ... default configuration. Example The following example displays the last TDR tests on all ports. The full syntax is 120 meters. The maximum length of the cable for the Time Domain Reflectometry (TDR) test is unit / port. Syntax show copper-ports tdr Port Result Length [meters] Date 1/g1 OK 1/g2 ...
User's Guide
Page 45
...device is through a Telnet connection, ensure the device has an IP address defined and that takes you are managing a stack, ensure the serial interface cable is similar to the console port or through a Telnet connection. Check Boxes Check Box Type Add Remove General selection Description...about configuring an initial IP Address, see "Configuration Overview." If access is connected to the device prior to a configuration page. Using Dell™ OpenManage™ Switch Administrator 45 Using the CLI is attached to the Master switch of log files, select match criteria for...
...device is through a Telnet connection, ensure the device has an IP address defined and that takes you are managing a stack, ensure the serial interface cable is similar to the console port or through a Telnet connection. Check Boxes Check Box Type Add Remove General selection Description...about configuring an initial IP Address, see "Configuration Overview." If access is connected to the device prior to a configuration page. Using Dell™ OpenManage™ Switch Administrator 45 Using the CLI is attached to the Master switch of log files, select match criteria for...
User's Guide
Page 46
... has not configured a login authentication method, then the console> prompt displays when the switch boots up enable passwords. 46 Using Dell™ OpenManage™ Switch Administrator ASCII terminals can be virtually connected to access configuration sub-systems. Privileged EXEC mode may occupy ...any location in the User EXEC mode. Only a limited subset of commands are installing a stack of the required console cable. 1. Otherwise, the user is presented with the quit or exit command. Your switch supports up for more information on ...
... has not configured a login authentication method, then the console> prompt displays when the switch boots up enable passwords. 46 Using Dell™ OpenManage™ Switch Administrator ASCII terminals can be virtually connected to access configuration sub-systems. Privileged EXEC mode may occupy ...any location in the User EXEC mode. Only a limited subset of commands are installing a stack of the required console cable. 1. Otherwise, the user is presented with the quit or exit command. Your switch supports up for more information on ...
User's Guide
Page 52
... modules. Connecting the Switch to the switch's serial port. 3. Connect the serial cable to a Terminal 1. Figure 3-4. If you are configuring a stack, connect the interface cable to Console 52 Cable and Port Information Serial Connection to Switch Serial Connector to the serial port of the...3-3. Connect the serial cable to the terminal (console) ASCII DTE RS-232. 2. These interfaces can also use the supplied serial cable (null-modem) to connect the switch to female DB-9 crossover cable. Bay 1 and Bay 2 Interfaces The Dell™ PowerConnect™ 6200series switches ...
... modules. Connecting the Switch to the switch's serial port. 3. Connect the serial cable to a Terminal 1. Figure 3-4. If you are configuring a stack, connect the interface cable to Console 52 Cable and Port Information Serial Connection to Switch Serial Connector to the serial port of the...3-3. Connect the serial cable to the terminal (console) ASCII DTE RS-232. 2. These interfaces can also use the supplied serial cable (null-modem) to connect the switch to female DB-9 crossover cable. Bay 1 and Bay 2 Interfaces The Dell™ PowerConnect™ 6200series switches ...
User's Guide
Page 61
...(W x D x H). Connect the terminal to the Master Switch. If you connect the terminal to a subordinate switch, you need to assemble and cable the stack before powering up for management through a serial interface. Hardware Description 61 NOTE: The console port supports asynchronous data of switches, you will not be... able to use the CLI. When a stack is powered up and configuring it. The default baud rate is 9600 bps. This port provides a direct connection to the switch and...
...(W x D x H). Connect the terminal to the Master Switch. If you connect the terminal to a subordinate switch, you need to assemble and cable the stack before powering up for management through a serial interface. Hardware Description 61 NOTE: The console port supports asynchronous data of switches, you will not be... able to use the CLI. When a stack is powered up and configuring it. The default baud rate is 9600 bps. This port provides a direct connection to the switch and...
User's Guide
Page 62
... front panel ports. Power Supplies The 6200 series switches have one of the short stacking cables into either of the stacking ports of the top switch and the switch directly below it. You can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the switches. See "System LEDs" for information on...
... front panel ports. Power Supplies The 6200 series switches have one of the short stacking cables into either of the stacking ports of the top switch and the switch directly below it. You can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the switches. See "System LEDs" for information on...
User's Guide
Page 106
If using the default baud rate does not result in 10 seconds then operational code will start. 1 - Use F2F null modem cable to connect the workstation to the Master Switch. 4. The system begins the boot process. Start operational code. 2 - Items such as addresses, versions, ...(up the switch. When the following screen is the default baud rate for each switch. 106 Configuring Dell PowerConnect Start Boot Menu. Connect the switch power cord and power up or down) are configuring a stack, connect the workstation to the switch. Select (1, 2):2 If you can enter the Boot menu by ...
If using the default baud rate does not result in 10 seconds then operational code will start. 1 - Use F2F null modem cable to connect the workstation to the Master Switch. 4. The system begins the boot process. Start operational code. 2 - Items such as addresses, versions, ...(up the switch. When the following screen is the default baud rate for each switch. 106 Configuring Dell PowerConnect Start Boot Menu. Connect the switch power cord and power up or down) are configuring a stack, connect the workstation to the switch. Select (1, 2):2 If you can enter the Boot menu by ...
User's Guide
Page 111
...-2000 01:43:03 %LINK-I-Up: 1/xg1 01-Jan-2000 01:43:34 %STP-I-PORTSTATUS: Port 1/xg1: STP status Forwarding Configuring Dell PowerConnect 111 Are you sure you want to reload the stack? (y/n) y Reloading all switches.. Ensure (on the serial console) that the STP status is set with the default settings. console> console... the switch through one of the Ethernet ports, or through a network connected to "up" and that the interface status changed to the switch, using a CAT5 Cable.
...-2000 01:43:03 %LINK-I-Up: 1/xg1 01-Jan-2000 01:43:34 %STP-I-PORTSTATUS: Port 1/xg1: STP status Forwarding Configuring Dell PowerConnect 111 Are you sure you want to reload the stack? (y/n) y Reloading all switches.. Ensure (on the serial console) that the STP status is set with the default settings. console> console... the switch through one of the Ethernet ports, or through a network connected to "up" and that the interface status changed to the switch, using a CAT5 Cable.
User's Guide
Page 115
... Information • Configuring SNTP Settings • Managing Logs • Defining IP Addressing • Running Cable Diagnostics • Managing Device Security • Captive Portal • Defining SNMP Parameters • File Management • Defining Advanced Settings • Defining Stacking • Trap Manager • sFlow • Industry Standard Discovery Protocol Configuring System Information 115 To...
... Information • Configuring SNTP Settings • Managing Logs • Defining IP Addressing • Running Cable Diagnostics • Managing Device Security • Captive Portal • Defining SNMP Parameters • File Management • Defining Advanced Settings • Defining Stacking • Trap Manager • sFlow • Industry Standard Discovery Protocol Configuring System Information 115 To...
User's Guide
Page 135
...after system reboot. Either the system startup log or the system operation log stores a message received by using the CLI, xmodem over the local serial cable, and TFTP. Upon system startup, 2.txt is removed, 1.txt is renamed 2.txt, 0.txt is renamed 1.txt, 0.txt is not supported. ...based upon the settings for message component and severity. This log always has the log full operation attribute set to three versions of stack platform. The system keeps up to 1000 messages. Local and remote configuration of the logging capability includes filtering of messages logged or forwarded...
...after system reboot. Either the system startup log or the system operation log stores a message received by using the CLI, xmodem over the local serial cable, and TFTP. Upon system startup, 2.txt is removed, 1.txt is renamed 2.txt, 0.txt is renamed 1.txt, 0.txt is not supported. ...based upon the settings for message component and severity. This log always has the log full operation attribute set to three versions of stack platform. The system keeps up to 1000 messages. Local and remote configuration of the logging capability includes filtering of messages logged or forwarded...
User's Guide
Page 320
... current. • Max. Half - Enables Auto Negotiation on the screen. 4. Auto Negotiation is a member of the firmware on 10GBase-T non-stacking ports. • Image Firmware Version - Displays the current Auto Negotiation setting. - 1000 Full - Indicates that enables a port to advertise its...for SFX7101 transceivers on the switch: - Indicates the statue of a LAG. • Current Flow Control - Up-to-date - Cable Length- Displays the maximum cable length determined by current power backoff level. Select a unit and port in the Unit and Port fields. 3. Click Apply Changes. ...
... current. • Max. Half - Enables Auto Negotiation on the screen. 4. Auto Negotiation is a member of the firmware on 10GBase-T non-stacking ports. • Image Firmware Version - Displays the current Auto Negotiation setting. - 1000 Full - Indicates that enables a port to advertise its...for SFX7101 transceivers on the switch: - Indicates the statue of a LAG. • Current Flow Control - Up-to-date - Cable Length- Displays the maximum cable length determined by current power backoff level. Select a unit and port in the Unit and Port fields. 3. Click Apply Changes. ...
Getting Started Guide
Page 7
...free-standing switch (four pads are managed, as a stack of switches that the chosen installation location meets the following items are included: • One PowerConnect switch • One AC power cable • One RS-232 cable • One rack-mount kit for rack installation (..., power lines, and fluorescent lighting fixtures. • Ambient - Installation This document provides basic information to install, configure, and operate Dell™ PowerConnect™ PC6224, PC6248, PC6224P, PC6248P, and PC6224F systems. For more information, see the User's Guide, which is available on ...
...free-standing switch (four pads are managed, as a stack of switches that the chosen installation location meets the following items are included: • One PowerConnect switch • One AC power cable • One RS-232 cable • One rack-mount kit for rack installation (..., power lines, and fluorescent lighting fixtures. • Ambient - Installation This document provides basic information to install, configure, and operate Dell™ PowerConnect™ PC6224, PC6248, PC6224P, PC6248P, and PC6224F systems. For more information, see the User's Guide, which is available on ...
Getting Started Guide
Page 9
... the back panel. This switch will not be able to support the weight of power, connect the 12 VDC power cable from a (separately purchased) PowerConnect RPS-600 for non-PoE switches or PowerConnect EPS-470 for PoE switches to the rack with either the rack bolts or cage nuts and cage nut bolts... rack-mounting holes on the switch line up for the first time, the switches elect the Master Switch, which may occupy any location in the stack. Install the switch on a flat surface if you have). Fasten the bolts on bottom before fastening the bolts on the front panel.
... the back panel. This switch will not be able to support the weight of power, connect the 12 VDC power cable from a (separately purchased) PowerConnect RPS-600 for non-PoE switches or PowerConnect EPS-470 for PoE switches to the rack with either the rack bolts or cage nuts and cage nut bolts... rack-mounting holes on the switch line up for the first time, the switches elect the Master Switch, which may occupy any location in the stack. Install the switch on a flat surface if you have). Fasten the bolts on bottom before fastening the bolts on the front panel.
Getting Started Guide
Page 10
... are added to 576 front panel ports. www.dell.com | support.dell.com Figure 1-2. Connecting Power Cable Assembling a Stack You can stack PowerConnect 6200 series switches up to 12 switches high, supporting up to a stack. 1 Install a separately purchased stacking module in rear "Bay 1" in a ring. 3 Make sure that the last stacking cable is connected from the last switch to the...
... are added to 576 front panel ports. www.dell.com | support.dell.com Figure 1-2. Connecting Power Cable Assembling a Stack You can stack PowerConnect 6200 series switches up to 12 switches high, supporting up to a stack. 1 Install a separately purchased stacking module in rear "Bay 1" in a ring. 3 Make sure that the last stacking cable is connected from the last switch to the...
Getting Started Guide
Page 11
Connecting a Stack of Switches NOTE: Long cable not shown in Figure 1-3. Getting Started Guide 9 The resulting ring topology allows the entire stack to function as a single switch with resilient fail-over capabilities. Figure 1-3.
Connecting a Stack of Switches NOTE: Long cable not shown in Figure 1-3. Getting Started Guide 9 The resulting ring topology allows the entire stack to function as a single switch with resilient fail-over capabilities. Figure 1-3.
Getting Started Guide
Page 12
...before powering up and configuring the stack. 1 Connect an RS-232 crossover cable to the terminal running VT100 terminal emulation software. • An RS-232 crossover cable with Microsoft Windows 2000, make sure that you need to assemble and cable the stack before proceeding. The console port .... 10 Getting Started Guide e Set the terminal emulation mode to configure the switch or stack. Connecting the Terminal to 9600 baud. You can download the release notes from the Dell Support website at support.dell.com. c Set the data format to none. d Set the flow control to 8...
...before powering up and configuring the stack. 1 Connect an RS-232 crossover cable to the terminal running VT100 terminal emulation software. • An RS-232 crossover cable with Microsoft Windows 2000, make sure that you need to assemble and cable the stack before proceeding. The console port .... 10 Getting Started Guide e Set the terminal emulation mode to configure the switch or stack. Connecting the Terminal to 9600 baud. You can download the release notes from the Dell Support website at support.dell.com. c Set the data format to none. d Set the flow control to 8...
Getting Started Guide
Page 13
... bolts. 3 Connect the female connector of switches, connect the terminal to the AC receptacle. 5 Activate the AC power receptacle. The PowerConnect 6200 series console ports are located on selftest (POST). Connecting to the Console Port Booting the Switch 1 Make sure that the switch console... you connect the terminal to a member switch, you are displayed on the front panel. POST messages are installing a stack of the RS-232 crossover cable directly to determine if the switch is fully operational before completely booting. The boot process runs for the first time, ...
... bolts. 3 Connect the female connector of switches, connect the terminal to the AC receptacle. 5 Activate the AC power receptacle. The PowerConnect 6200 series console ports are located on selftest (POST). Connecting to the Console Port Booting the Switch 1 Make sure that the switch console... you connect the terminal to a member switch, you are displayed on the front panel. POST messages are installing a stack of the RS-232 crossover cable directly to determine if the switch is fully operational before completely booting. The boot process runs for the first time, ...
Configuration Guide
Page 25
...There is an electrical short in the cable. • Cable Test Failed: The cable status could not be working. The command also returns a cable length estimate if this feature is not supported for optical fiber cable. NOTE: The cable test feature is run on the Stacking/CX-4/SFP+/10GbaseT ports. Unknown is ... that the test has not been performed. NOTE: The copper-related commands do not apply to a port. One of a copper cable attached to the stacking, 10G BaseT, or CX-4 ports associated with these plug-in fact be determined. In privileged exec mode, enter test copper-port tdr...
...There is an electrical short in the cable. • Cable Test Failed: The cable status could not be working. The command also returns a cable length estimate if this feature is not supported for optical fiber cable. NOTE: The cable test feature is run on the Stacking/CX-4/SFP+/10GbaseT ports. Unknown is ... that the test has not been performed. NOTE: The copper-related commands do not apply to a port. One of a copper cable attached to the stacking, 10G BaseT, or CX-4 ports associated with these plug-in fact be determined. In privileged exec mode, enter test copper-port tdr...