Get support for Dell PowerConnect 6248

Dell PowerConnect 6248 Support Question

Dell PowerConnect 6248 Support Question

Find answers below for this question about Dell PowerConnect 6248.
Need a Dell PowerConnect 6248 manual? We have 5 online manuals for this item!
Question posted by jimCamS on September 15th, 2013

How To Stack 2 Powerconnect 6200 Switches

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerConnect 6248 Manual Pages

Command Line Interface Guide - Page 1323

... command has no user guidelines. PCM8024 Plugged-in the stack. PCM8024 System Management Commands 1323 Field Switch Description Description This field displays the description for the switch. show switch Use the show switch [unit] command to display information about a specific unit on the stack. Use the show switch command in User EXEC mode to display the information...
Command Line Interface Guide - Page 1340

...1 renumber 2 telnet Use the telnet command in the stack. however, the old switch will be operationally unplugged. Upon execution, the switch is configured with the configuration information for becoming the Management Switch. The old switch configuration information is available. The current switch identifier. (Range: 1-12) • newunit - Example The following example displays...
User's Guide - Page 19

...8482; PowerConnect6200 series are provided with hot swappable stack members. The Dell PowerConnect 6224F switch supports 24 1000Base-FX SFP ports and 4 "combo" ports for RJ-45 or SFP interfaces. The topics covered in this product. For a list of Service Features • Multicast Features • Additional Documentation Introduction 19 The Dell PowerConnect 6224 switch supports...
User's Guide - Page 25

...Control Support (IEEE 802.3x) Flow control enables lower speed switches to configure the port speeds advertised. The PowerConnect 6200 Series enhances auto negotiation by traffic competing for the same ... (MDI) is the standard wiring for end stations, and the standard wiring for hubs and switches is unavailable for ports or LAGs, see "Port Configuration" or "LAG Configuration." ...
User's Guide - Page 38

... information about the command-line interface (CLI) commands used to configure and manage the switch and stack. Once established, such a connection is similar to use the PowerConnect 6200 Series in a typical network. It describes the advantages of users accessing the switch. The document provides in-depth CLI descriptions, syntax, default values, and usage guidelines. •...
User's Guide - Page 52

.... Bay 1 and Bay 2 PowerConnect 6200 Series 10 Gb Slots Serial Cable Connection You can use a computer running terminal emulation software). Connecting the Switch to the switch's serial port. 3. Figure 3-4. Connect the serial cable to a Terminal 1. The switch's serial cable is a female to the serial port of the Master switch. If you are configuring a stack, connect the interface...
User's Guide - Page 59

...stacking module. Figure 4-6. PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for XFP, CX4, or 10Gbase-T modules. PowerConnect 6224P and 6248P Rear Panel Dual 10G slots for XFP, CX4, or stacking... entire stack. Dual 10Gbps expansion slots are also mounted on the rear. Rear Panel Each PowerConnect 6200 series switch provides ...
User's Guide - Page 62

... as the PowerConnect RPS-600. You can stack up to 12 PowerConnect 6224 and/or 6248 switches, supporting up to connect the switches. If necessary, use a separately purchased, long (3 meter) stacking cable to 576 front panel ports. Repeat this process until all of the top switch and the switch directly below it. Power Supplies The 6200 series switches have one each...
User's Guide - Page 63

... the CLI to function as a Master failure is preconfigured in the stack fails. The Standby unit maintains a synchronized copy of PowerConnect 6200 Series Switches XG1 Port XG2 Port Unit 1 Unit 2 Unit 3 Unit 4 In Figure 4-13, the stack has the following physical connections between the switches: • Unit 1 and Unit 2 are connected through the XG1 ports on...
User's Guide - Page 254

... page contains the following fields: • Supported Switches - Displays a 256-byte data field used to the switch. • Switch Model ID - Moves the Management Switch functionality from one switch to identify the model of a stack. Stack Summary Commands CLI Command show switch switch priority switch renumber member movemanagement standby Description Displays information about all units...
Getting Started Guide - Page 6

... Assignment 16 Firmware Version Checking 16 System Initialization 17 CLI/ Telnet/ Web Interface 17 Insertion and Removal of Switches 17 Operating as Standalone Switch 17 Stack ID Renumbering 17 User Controls 18 4 Front Panels and LEDs Front Panels 19 LEDs 20 Systems LEDs 20 RJ-45 LEDs (PoE 21 XFP LED ...
Getting Started Guide - Page 18

... impact in the event of: • Switch failure • Inter-switch stacking link failure • Switch insertion • Switch removal If the Master Switch goes off line, any of the Member Switches in the stack are running on the Master Switch. 16 Getting Started Guide Auto Stack ID Assignment During the stack formation process, every switch is known as a single entity when...
Getting Started Guide - Page 19

...port enabled for the new Stack ID is complete, the Master Switch will take place. Operating as Standalone Switch If a switch cannot detect a stacking partner on the original Master Switch. Any configuration information that was saved for stacking, the switch will operate as a stack reconfiguration will enter Suspended Stacking Mode if the firmware versions of Switches You can save the...
Getting Started Guide - Page 20

movemanagement reload member set description switch priority switch renumber stacking show stack-port show stack-port counters show stack-port diag show switch show supported switchtype 18 Getting Started Guide See the CLI Reference Guide for details on the syntax of each command. www.dell.com | support.dell.com User Controls Use the following CLI commands to control this feature.
Getting Started Guide - Page 43

用户控件 CLI CLI movemanagement reload member set description switch priority switch renumber stacking show stack-port show stack-port counters show stack-port diag show switch show supported switchtype 41
Getting Started Guide - Page 141

CLI CLI movemanagement reload member set description switch priority switch renumber stacking show stack-port show stack-port counters show stack-port diag show switch show supported switchtype 139
Getting Started Guide - Page 165

以下の CLI CLI Reference Guide』(CLI movemanagement reload member set description switch priority switch renumber stacking show stack-port show stack-port counters show stack-port diag show switch show supported switchtype はじめに 163
Getting Started Guide - Page 188

www.dell.com | support.dell.com CLI CLI / WEB / SNMP 12 2 스택 ID ID ID ID ID 다음 CLI CLI movemanagement reload member set description switch priority switch renumber stacking show stack-port show stack-port counters show stack-port diag show switch show supported switchtype 186
Getting Started Guide - Page 266

...8235;‪show stack-port counters show stack-port diag show switch‬‬ ‫‪show supported switchtype‬‬ LED‬‬ LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224‬ו‪.PC6224F -‬‬ PowerConnect 6200 ‫‪PC 6224‬‬ 1-1‬‬ ‫‪PC 6248‬‬ 2-1‬...
Configuration Guide - Page 170

... multiple "best paths" to take advantage of NSF is left with no need to use . If a stack unit fails, the system can design your switch stack performs VLAN routing, another way to take maximum advantage of the stack. If a unit fails, the forwarding plane removes Equal Cost Multipath (ECMP) next hops on surviving units...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerConnect 6248 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.