User's Guide
Page 19
... Features • Multicast Features • Additional Documentation Introduction 19 Release notes are standalone Layer 2 and 3 switches that extend the Dell PowerConnect LAN switching product range. The Dell PowerConnect 6224P adds support for RJ-45 or SFP interfaces. The Dell PowerConnect 6224F switch supports 24 1000Base-FX SFP ports and 4 "combo" ports for power-over-Ethernet (PoE) capability. The...
... Features • Multicast Features • Additional Documentation Introduction 19 Release notes are standalone Layer 2 and 3 switches that extend the Dell PowerConnect LAN switching product range. The Dell PowerConnect 6224P adds support for RJ-45 or SFP interfaces. The Dell PowerConnect 6224F switch supports 24 1000Base-FX SFP ports and 4 "combo" ports for power-over-Ethernet (PoE) capability. The...
User's Guide
Page 57
PowerConnect 6224P with 24 SFP Ports SFP Ports Combo Ports The PowerConnect 6224P front panel provides 24 10/100/1000M Base-T RJ-45 ports and four RJ-45/SFP combo ports. Figure 4-4. Figure 4-3. PowerConnect 6224F with 24 10/100/1000 Base-T Ports 10/100/1000Base-T Auto-sensing Full Duplex RJ-45 Ports Combo Ports Hardware Description 57 The PowerConnect 6224F front panel provides 24 10/100/1000M Base-FX SFP ports and four RJ-45/SFP combo ports.
PowerConnect 6224P with 24 SFP Ports SFP Ports Combo Ports The PowerConnect 6224P front panel provides 24 10/100/1000M Base-T RJ-45 ports and four RJ-45/SFP combo ports. Figure 4-4. Figure 4-3. PowerConnect 6224F with 24 10/100/1000 Base-T Ports 10/100/1000Base-T Auto-sensing Full Duplex RJ-45 Ports Combo Ports Hardware Description 57 The PowerConnect 6224F front panel provides 24 10/100/1000M Base-FX SFP ports and four RJ-45/SFP combo ports.
User's Guide
Page 59
...can support a plug-in Dual 10GbE XFP module, a CX4 module, or a stacking module. Dual 10Gbps expansion slots are also mounted on the rear. PowerConnect 6224P and 6248P Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for XFP, CX4, or 10Gbase-T modules. The left slot... (Bay 1) can be used to manage an entire stack. RS-232 management port DC power AC power Figure 4-7. PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for XFP, CX4, or 10Gbase-T modules.
...can support a plug-in Dual 10GbE XFP module, a CX4 module, or a stacking module. Dual 10Gbps expansion slots are also mounted on the rear. PowerConnect 6224P and 6248P Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for XFP, CX4, or 10Gbase-T modules. The left slot... (Bay 1) can be used to manage an entire stack. RS-232 management port DC power AC power Figure 4-7. PowerConnect 6224, 6248, and 6224F Rear Panel Dual 10G slots for XFP, CX4, or stacking modules Dual 10G slots for XFP, CX4, or 10Gbase-T modules.
User's Guide
Page 66
... LED definitions for the PowerConnect 6224P and 6248P. The PoE powered device is detected and is operating at 10/100 Mbps. The port is operating at 10/100 Mbps. Link but no activity. No link. Full-duplex mode. Table 4-4. 10/100/1000 Base-T Port Definitions (6224, 6248, and 6224F) LED Link/Activity Color...
... LED definitions for the PowerConnect 6224P and 6248P. The PoE powered device is detected and is operating at 10/100 Mbps. The port is operating at 10/100 Mbps. Link but no activity. No link. Full-duplex mode. Table 4-4. 10/100/1000 Base-T Port Definitions (6224, 6248, and 6224F) LED Link/Activity Color...
Getting Started Guide
Page 21
PC 6224P Getting Started Guide 19 Front Panels and LEDs This appendix describes the front panels and LEDs of the Dell PowerConnect PC6224, PC6248, PC6224P, PC6248P, and PC6224F systems. Front Panels The front panels of the PowerConnect 6200 series systems are shown in the figures below. PC 6248 Figure 1-3. PC 6224 Figure 1-2. Figure 1-1.
PC 6224P Getting Started Guide 19 Front Panels and LEDs This appendix describes the front panels and LEDs of the Dell PowerConnect PC6224, PC6248, PC6224P, PC6248P, and PC6224F systems. Front Panels The front panels of the PowerConnect 6200 series systems are shown in the figures below. PC 6248 Figure 1-3. PC 6224 Figure 1-2. Figure 1-1.
Getting Started Guide
Page 266
show stack-port counters show stack-port diag show switch show supported switchtype LED LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224ו.PC6224F - PowerConnect 6200 PC 6224 1-1 PC 6248 2-1 PC 6224P 3-1 277
show stack-port counters show stack-port diag show switch show supported switchtype LED LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224ו.PC6224F - PowerConnect 6200 PC 6224 1-1 PC 6248 2-1 PC 6224P 3-1 277
Release Notes
Page 1
... the right to make changes without further notices to change without the prior written consent of Dell. Dell™ PowerConnect™ 6224/6224F/6224P/6248/6248P PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Date: May 2010 System Firmware Version 3.2.0.6 Information in trademarks and trade names other than its own. All rights reserved. All rights ...
... the right to make changes without further notices to change without the prior written consent of Dell. Dell™ PowerConnect™ 6224/6224F/6224P/6248/6248P PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Date: May 2010 System Firmware Version 3.2.0.6 Information in trademarks and trade names other than its own. All rights reserved. All rights ...
Release Notes
Page 3
...installing or upgrading of firmware be installed on every switch member. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Introduction This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6. You MUST follow the procedure set forth in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your switch becoming inoperable.... Global Support For information regarding the latest available firmware, release note revisions, or additional assistance, please visit the Support Web Site http://support.dell.com/.
...installing or upgrading of firmware be installed on every switch member. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Introduction This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6. You MUST follow the procedure set forth in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your switch becoming inoperable.... Global Support For information regarding the latest available firmware, release note revisions, or additional assistance, please visit the Support Web Site http://support.dell.com/.
Release Notes
Page 4
...operation. Hardware Supported PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P 2 System ...Firmware Version 3.2.0.6 Firmware Image Name PC6200v3.2.0.6.stk Version No. 3.2.0.6 Release Date May 2010 Version Numbering Convention Version number Description 6200 Series 3 2 0 6 Four part version number Denotes the build number. Users should upgrade to the Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide and the Dell™ PowerConnect...
...operation. Hardware Supported PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P 2 System ...Firmware Version 3.2.0.6 Firmware Image Name PC6200v3.2.0.6.stk Version No. 3.2.0.6 Release Date May 2010 Version Numbering Convention Version number Description 6200 Series 3 2 0 6 Four part version number Denotes the build number. Users should upgrade to the Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide and the Dell™ PowerConnect...
Release Notes
Page 5
... of the Day Banner The system supports a configurable message of the day banner that shows VLAN, STP, Port Status, and Port Configuration information etc. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Added Functionality in this Release ¾ Non-Stop Forwarding This feature creates an option to allow the stacking and CX-4 plug...
... of the Day Banner The system supports a configurable message of the day banner that shows VLAN, STP, Port Status, and Port Configuration information etc. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Added Functionality in this Release ¾ Non-Stop Forwarding This feature creates an option to allow the stacking and CX-4 plug...
Release Notes
Page 7
... SSH update incorporates the latest security and bug fixes. The miscreant sends ARP requests or responses mapping another station's IP address to its unsuspecting neighbors. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ MLD Snooping (RFC2710) In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of multicast traffic by...
... SSH update incorporates the latest security and bug fixes. The miscreant sends ARP requests or responses mapping another station's IP address to its unsuspecting neighbors. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ MLD Snooping (RFC2710) In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of multicast traffic by...
Release Notes
Page 9
... interfaces. ¾ Static Reject Routes Allows the user to configure a static route to discard the packets to the link (either a physical or virtual LAN). PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Ping/Traceroute Enhancements New ping options have been added to allow the user to -point circuit, even though the physical...
... interfaces. ¾ Static Reject Routes Allows the user to configure a static route to discard the packets to the link (either a physical or virtual LAN). PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Ping/Traceroute Enhancements New ping options have been added to allow the user to -point circuit, even though the physical...
Release Notes
Page 11
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Configured Tunnels MTU To comply with RFC 4213, Basic Transition Mechanisms for IPv6 Hosts and Routers, the IPv6 MTU on ...
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Configured Tunnels MTU To comply with RFC 4213, Basic Transition Mechanisms for IPv6 Hosts and Routers, the IPv6 MTU on ...
Release Notes
Page 13
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Changed Functionality in this state until it receives a BPDU and it receives a BPDU with the topology change notification. Setting the restricted ...
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Changed Functionality in this state until it receives a BPDU and it receives a BPDU with the topology change notification. Setting the restricted ...
Release Notes
Page 15
... for the GARP leave timer has been changed to ip mroute. The legacy commands are preserved for controlling traps was increased from 128 to 128. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Trap Configuration In previous versions of the software, configuration of places. The long parameter has been added to these...
... for the GARP leave timer has been changed to ip mroute. The legacy commands are preserved for controlling traps was increased from 128 to 128. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾ Trap Configuration In previous versions of the software, configuration of places. The long parameter has been added to these...
Release Notes
Page 17
... history rmon table-size log spanning-tree bpdu filtering MSTP Mode Description Interface Configuration mode Rationale: The following parameters have been deprecated since the 2.x release. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Deprecated Commands and Parameters The following CLI commands have been deprecated: • delete-on-reset • delete-on ports. Title...
... history rmon table-size log spanning-tree bpdu filtering MSTP Mode Description Interface Configuration mode Rationale: The following parameters have been deprecated since the 2.x release. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Deprecated Commands and Parameters The following CLI commands have been deprecated: • delete-on-reset • delete-on ports. Title...
Release Notes
Page 19
... show UTC time only. Firmware missing no version of issues resolved in connected_unit/connected_stby state. Asset-tag is not correctly populated on the DUT. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is expected as an SNMP trap receiver on the web page with the summertime taken into consideration...
... show UTC time only. Firmware missing no version of issues resolved in connected_unit/connected_stby state. Asset-tag is not correctly populated on the DUT. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is expected as an SNMP trap receiver on the web page with the summertime taken into consideration...
Release Notes
Page 21
... in recursive mode, clock zone field is limited to 250 such that verifies the session state. OpenManage Web UI shows invalid MAC address (all zeros. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Description Cannot enter Daylight Saving Time from Web interface.
... in recursive mode, clock zone field is limited to 250 such that verifies the session state. OpenManage Web UI shows invalid MAC address (all zeros. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Description Cannot enter Daylight Saving Time from Web interface.
Release Notes
Page 23
... - Use the "no" form of this command to show ip ospf Description Use this command to display the statistics for the check pointing process. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes CLI Reference Manual Updates Non-Stop Forwarding Title nsf no nsf show nsf show checkpoint statistics clear checkpoint statistics vlan routing...
... - Use the "no" form of this command to show ip ospf Description Use this command to display the statistics for the check pointing process. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes CLI Reference Manual Updates Non-Stop Forwarding Title nsf no nsf show nsf show checkpoint statistics clear checkpoint statistics vlan routing...
Release Notes
Page 25
... the client is executed. Dot1X Title dot1x timeout guest-vlan-period Description Use this command in modules as Ethernet ports. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes RADIUS Accounting Servers Title radius-server host acct Description The switches do not support creating accounting server ...CX-4 or stacking plug-in Interface Config Mode to disable banner acknowledge. If "n" is typed, the session is used to the Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide for 90 seconds. Default: From the factory the ports are all configured as either an...
... the client is executed. Dot1X Title dot1x timeout guest-vlan-period Description Use this command in modules as Ethernet ports. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes RADIUS Accounting Servers Title radius-server host acct Description The switches do not support creating accounting server ...CX-4 or stacking plug-in Interface Config Mode to disable banner acknowledge. If "n" is typed, the session is used to the Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide for 90 seconds. Default: From the factory the ports are all configured as either an...