User's Guide (.htm)
Page 40
...duplex/activity LED is located on the right side. www.dell.com | support.dell.com Physical Dimensions The PowerConnect 3424/P and PowerConnect 3448/P devices have the following figure illustrates the 10/100 Base-T port LEDs on the PowerConnect 3424 /P and PowerConnect 3448/P has two LEDs marked as LNK/ACT. 40 Hardware... FDX Speed/LNK/ACT FDX The RJ-45 100 Base-T port on The PowerConnect 3424 /P and PowerConnect 3448/P switches: Figure 2-6. The speed LED is located on the left side of links, power supplies, fans, and system diagnostics. Port LEDs Each 10/100/1000 Base-T port and ...
...duplex/activity LED is located on the right side. www.dell.com | support.dell.com Physical Dimensions The PowerConnect 3424/P and PowerConnect 3448/P devices have the following figure illustrates the 10/100 Base-T port LEDs on the PowerConnect 3424 /P and PowerConnect 3448/P has two LEDs marked as LNK/ACT. 40 Hardware... FDX Speed/LNK/ACT FDX The RJ-45 100 Base-T port on The PowerConnect 3424 /P and PowerConnect 3448/P switches: Figure 2-6. The speed LED is located on the left side of links, power supplies, fans, and system diagnostics. Port LEDs Each 10/100/1000 Base-T port and ...
User's Guide (.htm)
Page 44
... normally. Red Static One or more of The PowerConnect 3424 /P and PowerConnect 3448/P devices provide information about the power supplies, fans, thermal conditions, and diagnostics. Figure 2-9. Red Static The system diagnostic test failed. Red Static The device has crossed the permitted temperature range. www.dell.com | support.dell.com System LEDs The system LEDs of the...
... normally. Red Static One or more of The PowerConnect 3424 /P and PowerConnect 3448/P devices provide information about the power supplies, fans, thermal conditions, and diagnostics. Figure 2-9. Red Static The system diagnostic test failed. Red Static The device has crossed the permitted temperature range. www.dell.com | support.dell.com System LEDs The system LEDs of the...
User's Guide (.htm)
Page 47
.../P and PowerConnect 3448/P switches have five built-in stand-alone mode. If only a member unit is reset, the remain stacking members are present, the unit that indicates if one or more fans is booted in fans. If the Master device is reset, the entire stack is 4. The Stack Master ... the Backup Master. To select a Unit ID for the Stack Master and members. For example, if there are four units in fans. Ventilation System The PowerConnect 3424/P and PowerConnect 3448/P switches with the PoE feature have a reset button, located on the Unit ID of booting the device. The non-PoE...
.../P and PowerConnect 3448/P switches have five built-in stand-alone mode. If only a member unit is reset, the remain stacking members are present, the unit that indicates if one or more fans is booted in fans. If the Master device is reset, the entire stack is 4. The Stack Master ... the Backup Master. To select a Unit ID for the Stack Master and members. For example, if there are four units in fans. Ventilation System The PowerConnect 3424/P and PowerConnect 3448/P switches with the PoE feature have a reset button, located on the Unit ID of booting the device. The non-PoE...
User's Guide (.htm)
Page 71
...The software download procedure is completed 01-Jan-2000 01:01:19 %Box-I-FAN-STAT-CHNG: FAN# 1 status changed operational. To download software from the Startup menu: 1 From the Startup menu, press [1]. Number of configuration items loaded: 5 Loading startup configuration. PowerConnect 3424 HW Rev. 0.0 Unit Number 1 Standalone BOXP_high_appl_init: dpssIpcInitStandAlone Tapi Version... 128M bytes Dram first block size is : 36864K bytes Dram first PTR is : 0x1C00000 Flash size is: 16M Loading running configuration. Configuring PowerConnect 3424/P and 3448/P 71 Download Software -
...The software download procedure is completed 01-Jan-2000 01:01:19 %Box-I-FAN-STAT-CHNG: FAN# 1 status changed operational. To download software from the Startup menu: 1 From the Startup menu, press [1]. Number of configuration items loaded: 5 Loading startup configuration. PowerConnect 3424 HW Rev. 0.0 Unit Number 1 Standalone BOXP_high_appl_init: dpssIpcInitStandAlone Tapi Version... 128M bytes Dram first block size is : 36864K bytes Dram first PTR is : 0x1C00000 Flash size is: 16M Loading running configuration. Configuring PowerConnect 3424/P and 3448/P 71 Download Software -
User's Guide (.htm)
Page 72
www.dell.com | support.dell.com 01-Jan-2000 01:01:19 %Entity-I-SEND-ENT-CONF-CHANGE-TRAP: entity configuration change trap. 01-Jan-2000 01:01:19 %Box-I-FAN-STAT-CHNG: FAN# 2 status changed operational. 01-Jan-2000 01:01:19 %Box-I-PS-STAT-CHNG: PS# 1 status changed operational.... file name (Up to 8 characters, Enter for the file to erase flash file. About to the device once without password. 72 Configuring PowerConnect 3424/P and 3448/P The software is erased and the device reboots. 4 Repeat the device initial configuration. Are you sure (Y/N)? To erase the device configuration: ...
www.dell.com | support.dell.com 01-Jan-2000 01:01:19 %Entity-I-SEND-ENT-CONF-CHANGE-TRAP: entity configuration change trap. 01-Jan-2000 01:01:19 %Box-I-FAN-STAT-CHNG: FAN# 2 status changed operational. 01-Jan-2000 01:01:19 %Box-I-PS-STAT-CHNG: PS# 1 status changed operational.... file name (Up to 8 characters, Enter for the file to erase flash file. About to the device once without password. 72 Configuring PowerConnect 3424/P and 3448/P The software is erased and the device reboots. 4 Repeat the device initial configuration. Are you sure (Y/N)? To erase the device configuration: ...
User's Guide (.htm)
Page 91
...: Fan 2 Status: Temperature (Celsius): Temperature Sensor Status: OK NOT OPERATIONAL NOT OPERATIONAL 30 OK The following is an example of displaying system information for a stacked devices using the CLI commands: console# show system id Unit ---1 2 3 4 5 6 Serial number 893658972 893658973 893658974 893658975 893658976 893658977 console# show system Unit ---1 2 3 4 5 6 Type PowerConnect 3424 PowerConnect 3424 PowerConnect 3428 PowerConnect...
...: Fan 2 Status: Temperature (Celsius): Temperature Sensor Status: OK NOT OPERATIONAL NOT OPERATIONAL 30 OK The following is an example of displaying system information for a stacked devices using the CLI commands: console# show system id Unit ---1 2 3 4 5 6 Serial number 893658972 893658973 893658974 893658975 893658976 893658977 console# show system Unit ---1 2 3 4 5 6 Type PowerConnect 3424 PowerConnect 3424 PowerConnect 3428 PowerConnect...
User's Guide (.htm)
Page 99
... supply is operating normally. - Each fan is denoted as fan plus the fan number in Celsius. Fan Status - A fan is operating normally. - Temperature - The device temperature is displayed. The possible field values are : - The fan is currently not present. The fan is not operating normally. The power ...supply is not operating normally. The non-PoE devices have two fans, while the PoE devices have five fans. The temperature at which the device asset information is displayed in the interface. Configuring System Information 99...
... supply is operating normally. - Each fan is denoted as fan plus the fan number in Celsius. Fan Status - A fan is operating normally. - Temperature - The device temperature is displayed. The possible field values are : - The fan is currently not present. The fan is not operating normally. The power ...supply is not operating normally. The non-PoE devices have two fans, while the PoE devices have five fans. The temperature at which the device asset information is displayed in the interface. Configuring System Information 99...
User's Guide (.htm)
Page 101
...in the tree view. Powered Devices are connected via Ethernet ports. Powered devices are devices which receive power from the PowerConnect power supplies, for example IP phones. click System →General →Power over Ethernet removes the necessity of placing... Source -----AC AC Status -----OK OK Unit Fan ---- --- 1 CPU 2 CPU Status -----OK OK Managing Power over Ethernet Power over Ethernet (PoE) provides power to the PowerConnect device via either all PowerConnect 3424P's 24 FE ports or all PowerConnect 3448P's 48 FE ports. Configuring System Information 101...
...in the tree view. Powered Devices are connected via Ethernet ports. Powered devices are devices which receive power from the PowerConnect power supplies, for example IP phones. click System →General →Power over Ethernet removes the necessity of placing... Source -----AC AC Status -----OK OK Unit Fan ---- --- 1 CPU 2 CPU Status -----OK OK Managing Power over Ethernet Power over Ethernet (PoE) provides power to the PowerConnect device via either all PowerConnect 3424P's 24 FE ports or all PowerConnect 3448P's 48 FE ports. Configuring System Information 101...