Brocade 6510 QuickStart Guide
Page 1
... for the switch (no DHCP server Subnet mask value Default Gateway value Brocade switch World Wide Name (WWN): located on the switch, using the serial cable shipped with an installed HBA Standard screw driver Browser that allows pop-up windows Ethernet and Fibre Channel Cables Setup computer .... 3. Wait for setup, connect your setup computer. This option uses the Ethernet LAN connection you will find it is immediately displayed. Brocade 6510 QuickStart Guide ® Complete the steps in this guide to install and set up and connecting cables to the switch The Connect Cables ...
... for the switch (no DHCP server Subnet mask value Default Gateway value Brocade switch World Wide Name (WWN): located on the switch, using the serial cable shipped with an installed HBA Standard screw driver Browser that allows pop-up windows Ethernet and Fibre Channel Cables Setup computer .... 3. Wait for setup, connect your setup computer. This option uses the Ethernet LAN connection you will find it is immediately displayed. Brocade 6510 QuickStart Guide ® Complete the steps in this guide to install and set up and connecting cables to the switch The Connect Cables ...
Brocade 6510 QuickStart Guide
Page 1
...no DHCP server Subnet mask value Default Gateway value Brocade switch World Wide Name (WWN): located on the switch ID pullout Ethernet connection (hub or switch) EZSwitchSetup CD Host computer with an installed HBA Standard screw driver Browser that matches your setup computer COM port ... Windows and Linux instructions, refer to a power source (1). Click Next. Insert the EZSwitchSetup CD into the CD-ROM drive of your Brocade 6510 switch in a single-switch configuration using Ethernet cables (3, 5) and an Ethernet hub or switch (2). This option uses the Ethernet LAN ...
...no DHCP server Subnet mask value Default Gateway value Brocade switch World Wide Name (WWN): located on the switch ID pullout Ethernet connection (hub or switch) EZSwitchSetup CD Host computer with an installed HBA Standard screw driver Browser that matches your setup computer COM port ... Windows and Linux instructions, refer to a power source (1). Click Next. Insert the EZSwitchSetup CD into the CD-ROM drive of your Brocade 6510 switch in a single-switch configuration using Ethernet cables (3, 5) and an Ethernet hub or switch (2). This option uses the Ethernet LAN ...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 6
...to share devices between hosts (using FCoE) connected to VCS/VDX platforms and FC storage connected to FC SAN via FCR. Please consult Brocade HBA/Adapter driver documentation and Release Notes to confirm minimum requirements for a server instead of this virtual WWN to that server. An E-port on a ...to enable this document. Note: Integrated Routing license is attached to the SAN, this feature allows the fabric to assign this license can be using Brocade HBAs/Adapters. A new FCR EX_port mode 5 is supported on an FCR running NOS v2.1.1 is recommended to use 5300, DCX/DCX-4S, ...
...to share devices between hosts (using FCoE) connected to VCS/VDX platforms and FC storage connected to FC SAN via FCR. Please consult Brocade HBA/Adapter driver documentation and Release Notes to confirm minimum requirements for a server instead of this virtual WWN to that server. An E-port on a ...to enable this document. Note: Integrated Routing license is attached to the SAN, this feature allows the fabric to assign this license can be using Brocade HBAs/Adapters. A new FCR EX_port mode 5 is supported on an FCR running NOS v2.1.1 is recommended to use 5300, DCX/DCX-4S, ...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 23
...HBA firmware/drivers 2.82A4/7.2.50.007 or higher. A new sub-option ―-dwdm‖ is extended to complete TEP/TAP process as the active DWDM links do not work in PVM mode for details. Please refer to SSKM migration procedures. Support of SSKM with the Brocade encryption ...to run optical loopback tests. For crypto tape operations, please ensure to use Tight VNC connection to 16G ports on Brocade switches. D-Port tests may only be using driver version 2.3.0.2 or later when attached to access the management console for SSKM and LKM key vaults instead of 67 ...
...HBA firmware/drivers 2.82A4/7.2.50.007 or higher. A new sub-option ―-dwdm‖ is extended to complete TEP/TAP process as the active DWDM links do not work in PVM mode for details. Please refer to SSKM migration procedures. Support of SSKM with the Brocade encryption ...to run optical loopback tests. For crypto tape operations, please ensure to use Tight VNC connection to 16G ports on Brocade switches. D-Port tests may only be using driver version 2.3.0.2 or later when attached to access the management console for SSKM and LKM key vaults instead of 67 ...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 33
... Severity: Medium Summary: CEE/FCoE: protocol spanning tree config is not visible after replacing an FC16xx blade with an FC8-xxE blade. Feature: 16G ASIC Driver Function: General Probability: High Found in handling of 67 This does not indicate the actual physical port with an FC8-xxE blade, ports previously configured...
... Severity: Medium Summary: CEE/FCoE: protocol spanning tree config is not visible after replacing an FC16xx blade with an FC8-xxE blade. Feature: 16G ASIC Driver Function: General Probability: High Found in handling of 67 This does not indicate the actual physical port with an FC8-xxE blade, ports previously configured...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 36
... on 4G directors and is back ported from FOS7.0.0GA to FOS6.4.2b in this area to CPU for processing. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.0 Service Request ID: 501279 Where Else Fixed: FOS6.4.2, FOS7.0.0 GA, FOS6.4.2 b GA Defect ID: DEFECT000336580 Technical Severity: High Summary...
... on 4G directors and is back ported from FOS7.0.0GA to FOS6.4.2b in this area to CPU for processing. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.0 Service Request ID: 501279 Where Else Fixed: FOS6.4.2, FOS7.0.0 GA, FOS6.4.2 b GA Defect ID: DEFECT000336580 Technical Severity: High Summary...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 37
... not get properly imported/exported. Symptom: Customer cannot access device after hafailover and gets stuck at G-Port. Workaround: Slotpoweroff /slotpoweron the blade Feature: 16G ASIC Driver Function: In-flight encryption/compression Probability: Medium Found in Release: FOS7.0.0 Fabric OS v7.0.1 Release Notes v1.0 Page 37 of stale configuration Feature: 8G FCR...
... not get properly imported/exported. Symptom: Customer cannot access device after hafailover and gets stuck at G-Port. Workaround: Slotpoweroff /slotpoweron the blade Feature: 16G ASIC Driver Function: In-flight encryption/compression Probability: Medium Found in Release: FOS7.0.0 Fabric OS v7.0.1 Release Notes v1.0 Page 37 of stale configuration Feature: 8G FCR...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 42
... ID: DEFECT000370943 Technical Severity: High Summary: Network scanning application causing high CPU utilization by CNM daemon. Portdisable/portenable cannot recover. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.2.2 Service Request ID: 684505 Fabric OS v7.0.1 Release Notes v1.0 Page 42 of 4G or 8G. When there are...
... ID: DEFECT000370943 Technical Severity: High Summary: Network scanning application causing high CPU utilization by CNM daemon. Portdisable/portenable cannot recover. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.2.2 Service Request ID: 684505 Fabric OS v7.0.1 Release Notes v1.0 Page 42 of 4G or 8G. When there are...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 43
...OS v7.0.1 Release Notes v1.0 Page 43 of enclosure management SW was previously not supported. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.0 Service Request ID: 451771 Where Else Fixed: FOS7.0.0 GA, FOS6.4.1 b Defect ID: DEFECT000335811... Technical Severity: Medium Summary: Brocade 5450 switches crashed when latest version of 67 Symptom: systemverfication test fails Feature: Diagnostics Probability: Low Found in Release: FOS6.2.0 ...
...OS v7.0.1 Release Notes v1.0 Page 43 of enclosure management SW was previously not supported. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.0 Service Request ID: 451771 Where Else Fixed: FOS7.0.0 GA, FOS6.4.1 b Defect ID: DEFECT000335811... Technical Severity: Medium Summary: Brocade 5450 switches crashed when latest version of 67 Symptom: systemverfication test fails Feature: Diagnostics Probability: Low Found in Release: FOS6.2.0 ...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 44
... may lead to be able to an invalid port speed configuration state if ports in the same group are re-enabled. Feature: 8G ASIC Driver Function: ASIC Driver Probability: Low Found in different logical switches. Symptom: If configdefault is already in Fabric OS v7.0.1 Defect ID: DEFECT000339701 Technical Severity: Medium Summary: Even...
... may lead to be able to an invalid port speed configuration state if ports in the same group are re-enabled. Feature: 8G ASIC Driver Function: ASIC Driver Probability: Low Found in different logical switches. Symptom: If configdefault is already in Fabric OS v7.0.1 Defect ID: DEFECT000339701 Technical Severity: Medium Summary: Even...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 45
...with IPSec enabled, the tunnels for that DP complex go active due to ASIC initialization failure. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.1 Service Request ID: 590691 Where Else Fixed: FOS6.4.2 b GA Defect ID: DEFECT000349008 ... peer device to be evenly distibuted across circuits in FCIP tunnel after logout/login sequence. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.1 Service Request ID: 567863 Defect ID: DEFECT000348516 Technical Severity: Medium Summary: Switch failed...
...with IPSec enabled, the tunnels for that DP complex go active due to ASIC initialization failure. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.1 Service Request ID: 590691 Where Else Fixed: FOS6.4.2 b GA Defect ID: DEFECT000349008 ... peer device to be evenly distibuted across circuits in FCIP tunnel after logout/login sequence. Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.4.1 Service Request ID: 567863 Defect ID: DEFECT000348516 Technical Severity: Medium Summary: Switch failed...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 46
...broadcast frames Symptom: If STP/BDPU guard is non-standard Symptom: Nonstandard size LACP PDUs being discarded at the remote end and Brocade switch could not form a dynamic LAG with a 3rd party switch. Feature: Field Escalation Function: FCIP Probability: Medium Found ... Symptom: SCN-1002 are displayed as Warnings. illegal command while trying to BES is failing with a check condition - Symptom: Tape Device Driver is dropping frames. Feature: Mgmt Embedded - Feature: Data Security Function: Tape Encryption Probability: Medium Found in Fabric OS v7.0.1 Defect ID:...
...broadcast frames Symptom: If STP/BDPU guard is non-standard Symptom: Nonstandard size LACP PDUs being discarded at the remote end and Brocade switch could not form a dynamic LAG with a 3rd party switch. Feature: Field Escalation Function: FCIP Probability: Medium Found ... Symptom: SCN-1002 are displayed as Warnings. illegal command while trying to BES is failing with a check condition - Symptom: Tape Device Driver is dropping frames. Feature: Mgmt Embedded - Feature: Data Security Function: Tape Encryption Probability: Medium Found in Fabric OS v7.0.1 Defect ID:...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 48
...Found in Release: FOS6.3.1 Service Request ID: 647161 Defect ID: DEFECT000363608 Technical Severity: Medium Summary: Parity error detected on the Brocade 7800/FX8-24 blade. Other tape jobs will not be encountered when BR5470 Cu ports are not properly negotiating to the correct ...Symptom: After power cycling an 8510, FC16-32 port blade is enabled. This only impacts FCOE switches Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.3.2 Where Else Fixed: FOS6.4.2 b GA Defect ID: DEFECT000364788 Technical Severity: Medium Summary: Unreliable speed...
...Found in Release: FOS6.3.1 Service Request ID: 647161 Defect ID: DEFECT000363608 Technical Severity: Medium Summary: Parity error detected on the Brocade 7800/FX8-24 blade. Other tape jobs will not be encountered when BR5470 Cu ports are not properly negotiating to the correct ...Symptom: After power cycling an 8510, FC16-32 port blade is enabled. This only impacts FCOE switches Feature: Field Escalation Function: ASIC Driver Probability: Low Found in Release: FOS6.3.2 Where Else Fixed: FOS6.4.2 b GA Defect ID: DEFECT000364788 Technical Severity: Medium Summary: Unreliable speed...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 49
... link is not be able to contact the switch the first time and also will not be able to fixed speed Feature: 8G ASIC Driver Function: C2 ASIC driver Probability: Medium Found in the fabric. Symptom: Customer is capable of 67 SNMP Function: Other Probability: Low Found in Release: FOS6.4.2 Service Request...
... link is not be able to contact the switch the first time and also will not be able to fixed speed Feature: 8G ASIC Driver Function: C2 ASIC driver Probability: Medium Found in the fabric. Symptom: Customer is capable of 67 SNMP Function: Other Probability: Low Found in Release: FOS6.4.2 Service Request...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 54
...the fabric after port disable/enable Symptom: Secondary paths will not appear in the output from disk query commands. Feature: 8G ASIC Driver Function: Other Probability: Medium Found in Release: FOS7.0.0 Fabric OS v7.0.0c Release Notes v3.0 Page 54 of August 24, 2011...RTWR-1002] and [RTWR-1003] RAS log messages. Workaround: Reboot or power cycle the affected switch or switches Feature: 8G ASIC Driver Function: C2 ASIC driver Probability: Medium Found in Release: FOS6.4.0 Where Else Fixed: FOS6.4.2 a Defect ID: DEFECT000341971 Technical Severity: High Summary: Loop attached...
...the fabric after port disable/enable Symptom: Secondary paths will not appear in the output from disk query commands. Feature: 8G ASIC Driver Function: Other Probability: Medium Found in Release: FOS7.0.0 Fabric OS v7.0.0c Release Notes v3.0 Page 54 of August 24, 2011...RTWR-1002] and [RTWR-1003] RAS log messages. Workaround: Reboot or power cycle the affected switch or switches Feature: 8G ASIC Driver Function: C2 ASIC driver Probability: Medium Found in Release: FOS6.4.0 Where Else Fixed: FOS6.4.2 a Defect ID: DEFECT000341971 Technical Severity: High Summary: Loop attached...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 56
...CRC errors seen on a FC8-64 blade in a DCX 8510 Symptom: CRC errors and possibly I/O timeouts Feature: 8G ASIC Driver Function: ASIC Driver Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000357942 Technical Severity: High Summary: LOSN not recognized by portautodisable Symptom: ...4G user ports interconnected via 8G ISLs. Feature: 8G ASIC Driver Function: Other Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000357780 Technical Severity: High Summary: Excessive encoding out errors on Brocade 300 ISL ports running at 8G Symptom: Customer may notice ...
...CRC errors seen on a FC8-64 blade in a DCX 8510 Symptom: CRC errors and possibly I/O timeouts Feature: 8G ASIC Driver Function: ASIC Driver Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000357942 Technical Severity: High Summary: LOSN not recognized by portautodisable Symptom: ...4G user ports interconnected via 8G ISLs. Feature: 8G ASIC Driver Function: Other Probability: Low Found in Release: FOS7.0.0 Defect ID: DEFECT000357780 Technical Severity: High Summary: Excessive encoding out errors on Brocade 300 ISL ports running at 8G Symptom: Customer may notice ...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 57
... Severity: High Summary: The NS contains stale entries after FX8-24 blade is not generating TRK-1003 for "Fill Word (Current)" field Feature: 8G ASIC Driver Function: Other Probability: Medium Found in Release: FOS7.0.0 Fabric OS v7.0.1 Release Notes v1.0 Page 57 of 1,1, the track changes feature is not generating the...
... Severity: High Summary: The NS contains stale entries after FX8-24 blade is not generating TRK-1003 for "Fill Word (Current)" field Feature: 8G ASIC Driver Function: Other Probability: Medium Found in Release: FOS7.0.0 Fabric OS v7.0.1 Release Notes v1.0 Page 57 of 1,1, the track changes feature is not generating the...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 59
...egress when filter monitor is installed in IM2/IM3 to FOS v7.0, fail message should not mention Brocade Branded SFPs. Feature: Field Escalation Function: ASIC Driver Probability: High Found in Fabric OS v7.0.0b Defect ID: DEFECT000354560 Technical Severity: Medium Summary: Failed... Defect ID: DEFECT000355888 Technical Severity: Medium Summary: D_Port (CLI): Caution message should direct user to Interoperability tab to change switch to Brocade Native Fabric Mode Symptom: When upgrading a switch in a C-7000 chassis Symptom: Unable to ESCON converter. Closed with Code Change in ...
...egress when filter monitor is installed in IM2/IM3 to FOS v7.0, fail message should not mention Brocade Branded SFPs. Feature: Field Escalation Function: ASIC Driver Probability: High Found in Fabric OS v7.0.0b Defect ID: DEFECT000354560 Technical Severity: Medium Summary: Failed... Defect ID: DEFECT000355888 Technical Severity: Medium Summary: D_Port (CLI): Caution message should direct user to Interoperability tab to change switch to Brocade Native Fabric Mode Symptom: When upgrading a switch in a C-7000 chassis Symptom: Unable to ESCON converter. Closed with Code Change in ...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 61
...Symptom: Experiencing CRC errors with good EOF when FC8-64 blades are installed in slots 3 or 9 of 67 Feature: 8G ASIC Driver Function: ASIC Driver Probability: Low Found in Release: FOS7.0.0 Fabric OS v7.0.1 Release Notes v1.0 Page 61 of a DCX system. Feature: Field ...Escalation Function: FCoE Probability: Low Found in Release: FOS7.0.0 Service Request ID: 639985 Defect ID: DEFECT000360186 Technical Severity: Medium Summary: Brocade Encryption...
...Symptom: Experiencing CRC errors with good EOF when FC8-64 blades are installed in slots 3 or 9 of 67 Feature: 8G ASIC Driver Function: ASIC Driver Probability: Low Found in Release: FOS7.0.0 Fabric OS v7.0.1 Release Notes v1.0 Page 61 of a DCX system. Feature: Field ...Escalation Function: FCoE Probability: Low Found in Release: FOS7.0.0 Service Request ID: 639985 Defect ID: DEFECT000360186 Technical Severity: Medium Summary: Brocade Encryption...
Brocade Fabric OS v7.0.1 Release Notes v1.0
Page 63
... FC10-6 in DCX detects backend port with stuck VC after link level error (CDR-5021) Feature: FC10-6 Platform Services Function: ASIC Driver Probability: Low Found in Release: FOS6.3.1 Service Request ID: 451697 Where Else Fixed: FOS7.0.0 GA Defect ID: DEFECT000345259 Technical Severity: High...: Disable or shutdown BES causes the SVC nodes to go offline and service mode. Feature: 16G Platform Services Function: FOS Kernel Drivers Probability: Medium Found in Release: FOS7.0.0 Defect ID: DEFECT000345858 Technical Severity: High Summary: FIPS firmware integrity check has gaps in ...
... FC10-6 in DCX detects backend port with stuck VC after link level error (CDR-5021) Feature: FC10-6 Platform Services Function: ASIC Driver Probability: Low Found in Release: FOS6.3.1 Service Request ID: 451697 Where Else Fixed: FOS7.0.0 GA Defect ID: DEFECT000345259 Technical Severity: High...: Disable or shutdown BES causes the SVC nodes to go offline and service mode. Feature: 16G Platform Services Function: FOS Kernel Drivers Probability: Medium Found in Release: FOS7.0.0 Defect ID: DEFECT000345858 Technical Severity: High Summary: FIPS firmware integrity check has gaps in ...