Fabric OS Message Reference v7.1.0
Page 301
... problems on a blade are likely a hardware problem on the main board; The switch or specified blade is within the operational range of the airflow around the chassis. replace the blade. If this problem occurs on a blade, it usually indicates a hardware problem on the blade itself ,... Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that a blade in the specified slot or the switch (for environmental reasons; The Brocade 300 switch has 4 fans and 1 power supply, but these parts cannot be replaced: the entire switch is not being shutdown for environmental ...
... problems on a blade are likely a hardware problem on the main board; The switch or specified blade is within the operational range of the airflow around the chassis. replace the blade. If this problem occurs on a blade, it usually indicates a hardware problem on the blade itself ,... Message Type FFDC | LOG Severity CRITICAL Probable Cause Indicates that a blade in the specified slot or the switch (for environmental reasons; The Brocade 300 switch has 4 fans and 1 power supply, but these parts cannot be replaced: the entire switch is not being shutdown for environmental ...
Fabric OS Message Reference v7.1.0
Page 460
... FW Messages FW-1001 Message , value has changed alarm for this threshold. Verify that the location temperature is appropriate to a value that the fans and airflow of a switch are functioning normally, check the climate control in your switch. If so, a fan-failure message accompanies this message.
... FW Messages FW-1001 Message , value has changed alarm for this threshold. Verify that the location temperature is appropriate to a value that the fans and airflow of a switch are functioning normally, check the climate control in your switch. If so, a fan-failure message accompanies this message.
Fabric OS Message Reference v7.1.0
Page 585
...in the same direction. HIL-1612 Message MISMATCH in the same direction. This message is applicable only to the Brocade 6510. Recommended Action Ensure that the airflows of the power supply and fan assemblies must move in the same direction. System shutdown canceled. This message is...assemblies run in PSU-FAN Air Flow direction. Recommended Action Ensure that the airflows of the power supply and fan assemblies run in PSU-FAN Air Flow direction. The system continues to the Brocade 6510. HIL-1611 5 HIL-1611 Message MISMATCH in the same direction. Message...
...in the same direction. HIL-1612 Message MISMATCH in the same direction. This message is applicable only to the Brocade 6510. Recommended Action Ensure that the airflows of the power supply and fan assemblies must move in the same direction. System shutdown canceled. This message is...assemblies run in PSU-FAN Air Flow direction. Recommended Action Ensure that the airflows of the power supply and fan assemblies run in PSU-FAN Air Flow direction. The system continues to the Brocade 6510. HIL-1611 5 HIL-1611 Message MISMATCH in the same direction. Message...
Fabric OS MIB Reference v7.1.0
Page 232
...OS v2.6.1. Returns the serial ID if this sensor. Generic information on a Brocade 7500 or FR4-18i blade is for each individual sensor, where applicable: swSensorType connUnitSensorCharacteristic 1 (temperature) 3 (temperature) 2 (fan) 7 (airflow) 3 (power supply) 9 (power) Possible values are : • unknown...8226; other (2) • temperature (3) • pressure (4) • emf (5) • currentValue (6) Current is a keyword. • airflow (7) • frequency (8) • power (9) • door (10) - Each contains textual information about the GbE ports on ports for ...
...OS v2.6.1. Returns the serial ID if this sensor. Generic information on a Brocade 7500 or FR4-18i blade is for each individual sensor, where applicable: swSensorType connUnitSensorCharacteristic 1 (temperature) 3 (temperature) 2 (fan) 7 (airflow) 3 (power supply) 9 (power) Possible values are : • unknown...8226; other (2) • temperature (3) • pressure (4) • emf (5) • currentValue (6) Current is a keyword. • airflow (7) • frequency (8) • power (9) • door (10) - Each contains textual information about the GbE ports on ports for ...
Web Tools Administrator's Guide v7.1.0
Page 154
.... The AirFlow Direction column displays the direction state as either the fan number or the fan FRU number, depending on the Fan button indicates the overall status of the fan. 2. Select a logical switch from the Logical Switch drop-down list in Figure 29. The detailed fan status for the Brocade 6510 and Brocade 6520...
.... The AirFlow Direction column displays the direction state as either the fan number or the fan FRU number, depending on the Fan button indicates the overall status of the fan. 2. Select a logical switch from the Logical Switch drop-down list in Figure 29. The detailed fan status for the Brocade 6510 and Brocade 6520...