DSN-6110 Datasheet
Page 1
...; Industry Standard 2U 19-inch Chassis • Hardware iSCSI Offload Engine Transactional Performance • DSN-6110: Up to 200,000 • DSN-6410: Up to 220,000 Additional DSN-6020 Expansion JBODs: • Up to Four Additional JBODs (60 Drives Total) • ... • DSN-6110: Four 1GbE Data Ports per Controller • Add a DSN-610 Controller for High Availability (Active/Active Operation) • DSN-6410: Two 10GbE Data Ports per Controller • Add a DSN-640 Controller for High Availability (Active/Active Operation) Overview D-Link's DSN-6000 Series (DSN-6110 & DSN-6410) iSCSI...
...; Industry Standard 2U 19-inch Chassis • Hardware iSCSI Offload Engine Transactional Performance • DSN-6110: Up to 200,000 • DSN-6410: Up to 220,000 Additional DSN-6020 Expansion JBODs: • Up to Four Additional JBODs (60 Drives Total) • ... • DSN-6110: Four 1GbE Data Ports per Controller • Add a DSN-610 Controller for High Availability (Active/Active Operation) • DSN-6410: Two 10GbE Data Ports per Controller • Add a DSN-640 Controller for High Availability (Active/Active Operation) Overview D-Link's DSN-6000 Series (DSN-6110 & DSN-6410) iSCSI...
DSN-6110 Datasheet
Page 2
High Availability The DSN-6110 & DSN-6410 primary arrays, based on a single controller, each support Link Aggregation Groups (LAG), MultiPath I/O (MPIO) and Multiple Connections per Session (MCS) for flexibility, performance and resiliency. When deployed with redundant controllers, the DSN-6000 series is safe in the event... modules, battery backup modules, and SAS JBOD expansion ports. With the addition of a secondary controller (DSN-610 for the DSN-6110 and DSN-640 for the DSN-6410) the DSN-6000 Series can be used to backup data from a pointin-time copy and easily without the need...
High Availability The DSN-6110 & DSN-6410 primary arrays, based on a single controller, each support Link Aggregation Groups (LAG), MultiPath I/O (MPIO) and Multiple Connections per Session (MCS) for flexibility, performance and resiliency. When deployed with redundant controllers, the DSN-6000 series is safe in the event... modules, battery backup modules, and SAS JBOD expansion ports. With the addition of a secondary controller (DSN-610 for the DSN-6110 and DSN-640 for the DSN-6410) the DSN-6000 Series can be used to backup data from a pointin-time copy and easily without the need...
DSN-6110 Datasheet
Page 3
... D-Link Green features for a system reboot or any system downtime. These advanced features help to SATA drives installed in any system downtime. Unlike other RAID controller takes over • DSN-6110+DSN-610 • DSN-6410+DSN-640 SAS HDD No DSN-654 required SATA HDD Needs DSN-654 SAS HDD No DSN-654 required Expansion Options The DSN-6110 & DSN-6410...
... D-Link Green features for a system reboot or any system downtime. These advanced features help to SATA drives installed in any system downtime. Unlike other RAID controller takes over • DSN-6110+DSN-610 • DSN-6410+DSN-640 SAS HDD No DSN-654 required SATA HDD Needs DSN-654 SAS HDD No DSN-654 required Expansion Options The DSN-6110 & DSN-6410...
DSN-6110 Datasheet
Page 5
Auto Volume Rebuilding RAID Level Migration D-Link Green Auto Disk Spin Down Temperature Controlled Fans Power Supplies High Availability Active/Active RAID Controllers Flexible RAID Group Ownership Management Port Takeover Online ... Volume Configuration Restoration Hot Pluggable Battery Modules Volume Replication Tool Management Serial Console SSH Telnet HTTP Web User Interface Secured Web (HTTPS) iSNS S.E.S Notification Email DSN-6000 Series iSCSI SAN Array • Yes • Online volume migration without system downtime • Yes • Yes • 80 PLUS energy-efficient power ...
Auto Volume Rebuilding RAID Level Migration D-Link Green Auto Disk Spin Down Temperature Controlled Fans Power Supplies High Availability Active/Active RAID Controllers Flexible RAID Group Ownership Management Port Takeover Online ... Volume Configuration Restoration Hot Pluggable Battery Modules Volume Replication Tool Management Serial Console SSH Telnet HTTP Web User Interface Secured Web (HTTPS) iSNS S.E.S Notification Email DSN-6000 Series iSCSI SAN Array • Yes • Online volume migration without system downtime • Yes • Yes • 80 PLUS energy-efficient power ...
DSN-6110 Datasheet
Page 7
...;2012 D-Link Corporation/D-Link Systems, Inc. DSN-6000 Series iSCSI SAN Array Ordering Information Part Number Description DSN-6110 4x1GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6410 2x10GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6020 iSCSI SAN Expansion JBOD, 12 Bays, 2U DSN-610 4x1GbE Secondary iSCSI SAN Controller for DSN-6110 DSN-640 2x10GbE...
...;2012 D-Link Corporation/D-Link Systems, Inc. DSN-6000 Series iSCSI SAN Array Ordering Information Part Number Description DSN-6110 4x1GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6410 2x10GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6020 iSCSI SAN Expansion JBOD, 12 Bays, 2U DSN-610 4x1GbE Secondary iSCSI SAN Controller for DSN-6110 DSN-640 2x10GbE...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 1
D-Link iSCSI IP SAN storage GbE iSCSI to SATA II / SAS RAID IP SAN storage DSN-6110 & DSN-6110 with DSN-610 User Manual Version 1.0 1
D-Link iSCSI IP SAN storage GbE iSCSI to SATA II / SAS RAID IP SAN storage DSN-6110 & DSN-6110 with DSN-610 User Manual Version 1.0 1
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 2
... their respective companies. Refer all models. Preface Copyright Copyright@2012, D-Link Corporation. Caution Do not attempt to electric shock. All rights reserved. Information contained in this configuration DSN-6110: Single controller, can be reproduced or transmitted without notice. DSN-6110 with DSN-610: Dual controllers. - DSN-61x0 IP SAN storages stand for all servicing to dual mode...
... their respective companies. Refer all models. Preface Copyright Copyright@2012, D-Link Corporation. Caution Do not attempt to electric shock. All rights reserved. Information contained in this configuration DSN-6110: Single controller, can be reproduced or transmitted without notice. DSN-6110 with DSN-610: Dual controllers. - DSN-61x0 IP SAN storages stand for all servicing to dual mode...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 6
...box is the most cost-effective disk array system with a high degree of the data as usual without any impact on the existing data. DSN-6110 & 6110w/610 IP SAN storage connects to the specific or other application. Data can be recovered from the existing data and parity drives.... (Data can be recovered from the rest drives.) Figure 1.1.1 (DSN-6110 & 6110w/610) Snapshot-on the modification. D-Link IP SAN storage is a fully usable copy of a defined collection of data that it appeared at the point in time, ...
...box is the most cost-effective disk array system with a high degree of the data as usual without any impact on the existing data. DSN-6110 & 6110w/610 IP SAN storage connects to the specific or other application. Data can be recovered from the existing data and parity drives.... (Data can be recovered from the rest drives.) Figure 1.1.1 (DSN-6110 & 6110w/610) Snapshot-on the modification. D-Link IP SAN storage is a fully usable copy of a defined collection of data that it appeared at the point in time, ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 7
1.1.1 Highlights • D-Link DSN-6110 & 6110w/610 feature highlights Host Interface 8 x iSCSI GbE ports (DSN-6110w/DSN-610) 4 x iSCSI GbE ports (DSN-6110) Drive Interface 12 x SAS or SATA II RAID Controllers Single controller, can be upgradable to dual (DSN-6110) Dual-active RAID controllers (DSN-6110w/DSN-610) Scalability SAS JBOD expansion port Green Auto disk spin-down Advanced cooling RAID...
1.1.1 Highlights • D-Link DSN-6110 & 6110w/610 feature highlights Host Interface 8 x iSCSI GbE ports (DSN-6110w/DSN-610) 4 x iSCSI GbE ports (DSN-6110) Drive Interface 12 x SAS or SATA II RAID Controllers Single controller, can be upgradable to dual (DSN-6110) Dual-active RAID controllers (DSN-6110w/DSN-610) Scalability SAS JBOD expansion port Green Auto disk spin-down Advanced cooling RAID...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 9
.... GS is in which the completion of the array's member disks are only used by one short time interval. Network Interface Card. World Wide Name. Link Aggregation Control Protocol. 9 Others could not use the global spare disks for rebuilding, they could get the spare disks out from the common spare disks...
.... GS is in which the completion of the array's member disks are only used by one short time interval. Network Interface Card. World Wide Name. Link Aggregation Control Protocol. 9 Others could not use the global spare disks for rebuilding, they could get the spare disks out from the common spare disks...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 11
...) and owns one hard drive. 1.2.3 Volume relationship The below graphic describes the relationship of "Just a Bunch Of Disks". The VDs in TCP/IP packets for linking storage devices with servers over common IP infrastructures. iSCSI provides high performance SANs over the member RAID 5 volumes. All VDs share the CV (Cache Volume...
...) and owns one hard drive. 1.2.3 Volume relationship The below graphic describes the relationship of "Just a Bunch Of Disks". The VDs in TCP/IP packets for linking storage devices with servers over common IP infrastructures. iSCSI provides high performance SANs over the member RAID 5 volumes. All VDs share the CV (Cache Volume...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 12
... target. IP-SANs also include mechanisms for the latest certification list. The initiator can be software or hardware (HBA). These ends are the available links: 1. It requests all SCSI operations like read or write. The target is usually located on board. Please refer to an attached storage device. ...Ethernet hardware, while iSCSI HBA(s) use their own iSCSI and TCP/IP stacks on the host side (either an iSCSI HBA or iSCSI SW initiator). Link to the vendors' HBA user manual. In addition, it can be used by using iSCSI over iSCSI. Storage protocol, such as iSCSI, has ...
... target. IP-SANs also include mechanisms for the latest certification list. The initiator can be software or hardware (HBA). These ends are the available links: 1. It requests all SCSI operations like read or write. The target is usually located on board. Please refer to an attached storage device. ...Ethernet hardware, while iSCSI HBA(s) use their own iSCSI and TCP/IP stacks on the host side (either an iSCSI HBA or iSCSI SW initiator). Link to the vendors' HBA user manual. In addition, it can be used by using iSCSI over iSCSI. Storage protocol, such as iSCSI, has ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 14
... UPS 5. Hot pluggable BBM support 10. Two power supplies 13. Write-through or write-back cache policy for high data protection 4. Auto volume rebuilding 11. D-Link writeable snapshot Built-in snapshot with no system down-time • Advanced data protection 1. Microsoft Windows Volume Shadow Copy Services (VSS) 3. Configurable N-way mirror...
... UPS 5. Hot pluggable BBM support 10. Two power supplies 13. Write-through or write-back cache policy for high data protection 4. Auto volume rebuilding 11. D-Link writeable snapshot Built-in snapshot with no system down-time • Advanced data protection 1. Microsoft Windows Volume Shadow Copy Services (VSS) 3. Configurable N-way mirror...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 27
....ssh.com/ PuTTY: http://www.chiark.greenend.org.uk/ Host name: 192.168.0.32 (Default IP) Login name: admin Default password: 123456 Tips D-Link product supports SSH for remote login. Be sure to figure 2.3.1. For using SSH, the IP address and password are three management methods to manage...for remote control only. open the browser and enter: http://192.168.0.32 And then it will pop up a dialog for login. 3.1.3 Web UI D-Link IP SAN storage supports graphic user interface (GUI) to RS 232 port of management PC. Chapter 3 Quick setup 3.1 Management interfaces There are required for ...
....ssh.com/ PuTTY: http://www.chiark.greenend.org.uk/ Host name: 192.168.0.32 (Default IP) Login name: admin Default password: 123456 Tips D-Link product supports SSH for remote login. Be sure to figure 2.3.1. For using SSH, the IP address and password are three management methods to manage...for remote control only. open the browser and enter: http://192.168.0.32 And then it will pop up a dialog for login. 3.1.3 Web UI D-Link IP SAN storage supports graphic user interface (GUI) to RS 232 port of management PC. Chapter 3 Quick setup 3.1 Management interfaces There are required for ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 41
...homed mode, or the link aggregation / trunking mode has been set with static IP.) • IP settings: User can enable event log display on each controller. 4 data ports are set up the "Entity Property", "NIC", "Node", "Session", and "CHAP account". DSN-6110 & 6110w/610 has four... gigabit ports on "Pop up events". 4.3 iSCSI configuration "iSCSI configuration" is designed for iSCSI ports". There are multiple data ports setting up in link aggregation or trunking mode, all the data ports share single ...
...homed mode, or the link aggregation / trunking mode has been set with static IP.) • IP settings: User can enable event log display on each controller. 4 data ports are set up the "Entity Property", "NIC", "Node", "Session", and "CHAP account". DSN-6110 & 6110w/610 has four... gigabit ports on "Pop up events". 4.3 iSCSI configuration "iSCSI configuration" is designed for iSCSI ports". There are multiple data ports setting up in link aggregation or trunking mode, all the data ports share single ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 42
Each of iSCSI data port is not link aggregation and trunking. Multi-homed: Default mode. Select this mode can also remove the setting of any...8226; Default gateway: Default gateway can be changed by sending 42 Maximum jumbo frame size is also for Multipath functions. LACP: The Link Aggregation Control Protocol (LACP) is the description of switching hub and HBA on host must be enabled. LACP allows a network switch to...of IEEE specification 802.3ad that allows bundling several physical ports together to increase the link speed beyond the limits of Trunking / LACP in same time. 2.
Each of iSCSI data port is not link aggregation and trunking. Multi-homed: Default mode. Select this mode can also remove the setting of any...8226; Default gateway: Default gateway can be changed by sending 42 Maximum jumbo frame size is also for Multipath functions. LACP: The Link Aggregation Control Protocol (LACP) is the description of switching hub and HBA on host must be enabled. LACP allows a network switch to...of IEEE specification 802.3ad that allows bundling several physical ports together to increase the link speed beyond the limits of Trunking / LACP in same time. 2.
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 43
... click "Ping host". 43 Figure 4.3.1.3 (Figure 4.3.1.3: There are 4 iSCSI data ports on a port. The advantages of LAN port, click "Delete link aggregation". LAN3 and LAN4 are set as Trunking mode. To remove Trunking / LACP setting, check the gray button of LACP are (1) increases the bandwidth.... (2) failover when link status fails on each controller, select at least two NICs for link aggregation.) Figure 4.3.1.4 For example, LAN1 and LAN2 are set as LACP mode. LACP packets to confirm. ...
... click "Ping host". 43 Figure 4.3.1.3 (Figure 4.3.1.3: There are 4 iSCSI data ports on a port. The advantages of LAN port, click "Delete link aggregation". LAN3 and LAN4 are set as Trunking mode. To remove Trunking / LACP setting, check the gray button of LACP are (1) increases the bandwidth.... (2) failover when link status fails on each controller, select at least two NICs for link aggregation.) Figure 4.3.1.4 For example, LAN1 and LAN2 are set as LACP mode. LACP packets to confirm. ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 49
..." to the number of slot, it will show up the volume configuration which can view the status of PD 4, select "Set Dedicated spare", it will link to dedicated spare disk. 3. The followings are operational steps: 1. For example, set PD slot number 4 to next page. 49 Step 1: Check to the gray button...
..." to the number of slot, it will show up the volume configuration which can view the status of PD 4, select "Set Dedicated spare", it will link to dedicated spare disk. 3. The followings are operational steps: 1. For example, set PD slot number 4 to next page. 49 Step 1: Check to the gray button...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 61
... be read / write. 61 Then click "OK". click "Expose". Figure 4.4.4.3 Step 4: Expose the snapshot VD. The snapshot space is zero, the exposed snapshot VD will link to take a snapshot. It will be the maximum capacity for saving snapshot index.) Step 3: Take a snapshot. Step 2: Set snapshot space. Enter a capacity for more detail...
... be read / write. 61 Then click "OK". click "Expose". Figure 4.4.4.3 Step 4: Expose the snapshot VD. The snapshot space is zero, the exposed snapshot VD will link to take a snapshot. It will be the maximum capacity for saving snapshot index.) Step 3: Take a snapshot. Step 2: Set snapshot space. Enter a capacity for more detail...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 80
... the status of RG is changed to degraded mode, the system will search/detect spare disk to rebuild the degraded RG to a complete one. D-LINK IP SAN storage supports Auto-Rebuild. If the new added disk is not clean (with other RG information), it would be marked as spare disk... and wait until (1) there is one disk assigned as RS (reserved) and the system will be in percentage. The following table is called recover; D-LINK suggests all customers not to any existing RG, it will start "auto-rebuild". Sometimes, rebuild is the relationship between RAID levels and rebuild. 80 It...
... the status of RG is changed to degraded mode, the system will search/detect spare disk to rebuild the degraded RG to a complete one. D-LINK IP SAN storage supports Auto-Rebuild. If the new added disk is not clean (with other RG information), it would be marked as spare disk... and wait until (1) there is one disk assigned as RS (reserved) and the system will be in percentage. The following table is called recover; D-LINK suggests all customers not to any existing RG, it will start "auto-rebuild". Sometimes, rebuild is the relationship between RAID levels and rebuild. 80 It...