DSN-6110 Datasheet
Page 1
... Drives High Performance iSCSI Interface: • DSN-6110: Four 1GbE Data Ports per Controller • Add a DSN-610 Controller for High Availability (Active/Active Operation) • DSN-6410: Two 10GbE Data Ports per Controller • Add a DSN-640 Controller for High Availability (Active/Active Operation) Overview D-Link's DSN-6000 Series (DSN-6110 & DSN-6410) iSCSI SAN array is a highly...
... Drives High Performance iSCSI Interface: • DSN-6110: Four 1GbE Data Ports per Controller • Add a DSN-610 Controller for High Availability (Active/Active Operation) • DSN-6410: Two 10GbE Data Ports per Controller • Add a DSN-640 Controller for High Availability (Active/Active Operation) Overview D-Link's DSN-6000 Series (DSN-6110 & DSN-6410) iSCSI SAN array is a highly...
DSN-6110 Datasheet
Page 2
... utilizes two built-in your primary site or data center. Up to 650 MB/s. High Availability The DSN-6110 & DSN-6410 primary arrays, based on a single controller, each support Link Aggregation Groups (LAG), MultiPath I/O (MPIO) and Multiple Connections per Session (MCS) for flexibility, performance and ... • Auto Fan Speed • 80 PLUS Energy-Efficient Power Supply A Choice of a secondary controller (DSN-610 for the DSN-6110 and DSN-640 for the DSN-6410) the DSN-6000 Series can be restored quickly and easily from a backup. Snapshot technology ensures data can have its four ...
... utilizes two built-in your primary site or data center. Up to 650 MB/s. High Availability The DSN-6110 & DSN-6410 primary arrays, based on a single controller, each support Link Aggregation Groups (LAG), MultiPath I/O (MPIO) and Multiple Connections per Session (MCS) for flexibility, performance and ... • Auto Fan Speed • 80 PLUS Energy-Efficient Power Supply A Choice of a secondary controller (DSN-610 for the DSN-6110 and DSN-640 for the DSN-6410) the DSN-6000 Series can be restored quickly and easily from a backup. Snapshot technology ensures data can have its four ...
DSN-6110 Datasheet
Page 3
..., the other vendors, D-Link's DSN-6000 Series (with a secondary controller installed) is down feature. Unlike other RAID controller takes over • DSN-6110+DSN-610 • DSN-6410+DSN-640 SAS HDD No DSN-654 required SATA HDD Needs DSN-654 SAS HDD No DSN-654 required Firmware images and...features help to upgrade its iSCSI interface, D-Link's DSN-6000 Series is critical in case of 3TB or greater, as cloud storage, SQL, Microsoft Exchange, video editing and video streaming applications. Expansion Options The DSN-6110 & DSN-6410 primary arrays each drive, for SATA ...
..., the other vendors, D-Link's DSN-6000 Series (with a secondary controller installed) is down feature. Unlike other RAID controller takes over • DSN-6110+DSN-610 • DSN-6410+DSN-640 SAS HDD No DSN-654 required SATA HDD Needs DSN-654 SAS HDD No DSN-654 required Firmware images and...features help to upgrade its iSCSI interface, D-Link's DSN-6000 Series is critical in case of 3TB or greater, as cloud storage, SQL, Microsoft Exchange, video editing and video streaming applications. Expansion Options The DSN-6110 & DSN-6410 primary arrays each drive, for SATA ...
DSN-6110 Datasheet
Page 5
Auto Volume Rebuilding RAID Level Migration D-Link Green Auto Disk Spin Down Temperature Controlled Fans Power Supplies High Availability Active/Active RAID Controllers Flexible RAID Group Ownership Management Port Takeover Online ... Volume Configuration Restoration Hot Pluggable Battery Modules Volume Replication Tool Management Serial Console SSH Telnet HTTP Web User Interface Secured Web (HTTPS) iSNS S.E.S Notification Email DSN-6000 Series iSCSI SAN Array • Yes • Online volume migration without system downtime • Yes • Yes • 80 PLUS energy-efficient power ...
Auto Volume Rebuilding RAID Level Migration D-Link Green Auto Disk Spin Down Temperature Controlled Fans Power Supplies High Availability Active/Active RAID Controllers Flexible RAID Group Ownership Management Port Takeover Online ... Volume Configuration Restoration Hot Pluggable Battery Modules Volume Replication Tool Management Serial Console SSH Telnet HTTP Web User Interface Secured Web (HTTPS) iSNS S.E.S Notification Email DSN-6000 Series iSCSI SAN Array • Yes • Online volume migration without system downtime • Yes • Yes • 80 PLUS energy-efficient power ...
DSN-6110 Datasheet
Page 7
... D-Link Corporation or its subsidiaries in U.S.A. Building Networks for more information U.S.A. | 17595 Mt. DSN-6000 Series iSCSI SAN Array Ordering Information Part Number Description DSN-6110 4x1GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6410 2x10GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6020 iSCSI SAN Expansion JBOD, 12 Bays, 2U DSN-610...
... D-Link Corporation or its subsidiaries in U.S.A. Building Networks for more information U.S.A. | 17595 Mt. DSN-6000 Series iSCSI SAN Array Ordering Information Part Number Description DSN-6110 4x1GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6410 2x10GbE iSCSI SAN Array, 12 Bays, 2U, w/Primary Controller DSN-6020 iSCSI SAN Expansion JBOD, 12 Bays, 2U DSN-610...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 1
D-Link iSCSI IP SAN storage GbE iSCSI to SATA II / SAS RAID IP SAN storage DSN-6110 & DSN-6110 with DSN-610 User Manual Version 1.0 1
D-Link iSCSI IP SAN storage GbE iSCSI to SATA II / SAS RAID IP SAN storage DSN-6110 & DSN-6110 with DSN-610 User Manual Version 1.0 1
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 2
... all servicing to change , disassemble or upgrade the equipment's components by yourself. DSN-61x0 IP SAN storages stand for this manual may violate your warranty and expose you to service, change without written permission from D-Link Corporation. Please always follow the instructions in this manual This manual is the introduction...herein are not available in this user's manual. 2 Refer all models. For any update information, please visit www.dlink.com. This manual will use "DSN-6110w/DSN-610" for the following models. Trademarks All products and trade names used in the...
... all servicing to change , disassemble or upgrade the equipment's components by yourself. DSN-61x0 IP SAN storages stand for this manual may violate your warranty and expose you to service, change without written permission from D-Link Corporation. Please always follow the instructions in this manual This manual is the introduction...herein are not available in this user's manual. 2 Refer all models. For any update information, please visit www.dlink.com. This manual will use "DSN-6110w/DSN-610" for the following models. Trademarks All products and trade names used in the...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 6
... Data can be recovered from the rest drives.) Figure 1.1.1 (DSN-6110 & 6110w/610) Snapshot-on the existing data. Rollback feature is provided for restoring the previous-snapshot data easily while continuously using D-Link RAID technology and advanced array management features. The IP SAN storage...is taken at target side. The snapshot copies can keep up to the specific or other application. Chapter 1 Overview 1.1 Features D-Link DSN-6000 series IP SAN storage provides non-stop service with completely integrated high-performance and data-protection capabilities which includes read / write ...
... Data can be recovered from the rest drives.) Figure 1.1.1 (DSN-6110 & 6110w/610) Snapshot-on the existing data. Rollback feature is provided for restoring the previous-snapshot data easily while continuously using D-Link RAID technology and advanced array management features. The IP SAN storage...is taken at target side. The snapshot copies can keep up to the specific or other application. Chapter 1 Overview 1.1 Features D-Link DSN-6000 series IP SAN storage provides non-stop service with completely integrated high-performance and data-protection capabilities which includes read / write ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 7
1.1.1 Highlights • D-Link DSN-6110 & 6110w/610 feature highlights Host Interface 8 x iSCSI GbE ports (DSN-6110w/DSN-610) 4 x iSCSI GbE ports (DSN-6110) Drive Interface 12 x SAS or SATA II RAID Controllers Single controller, can be upgradable to dual (DSN-6110) Dual-active RAID controllers (DSN-6110w/DSN-610) Scalability SAS JBOD expansion port Green Auto disk spin-down Advanced cooling RAID...
1.1.1 Highlights • D-Link DSN-6110 & 6110w/610 feature highlights Host Interface 8 x iSCSI GbE ports (DSN-6110w/DSN-610) 4 x iSCSI GbE ports (DSN-6110) Drive Interface 12 x SAS or SATA II RAID Controllers Single controller, can be upgradable to dual (DSN-6110) Dual-active RAID controllers (DSN-6110w/DSN-610) Scalability SAS JBOD expansion port Green Auto disk spin-down Advanced cooling RAID...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 9
... needs to its virtual disks. Global Spare disks. Small Computer Systems Interface. Battery Backup Module • Part 2: iSCSI iSCSI LACP Internet Small Computer Systems Interface. Link Aggregation Control Protocol. 9 Write-Back cache-write policy. DeGraded mode. WB RO DS GS DG SCSI SAS S.M.A.R.T. A caching technique in which the completion of the...
... needs to its virtual disks. Global Spare disks. Small Computer Systems Interface. Battery Backup Module • Part 2: iSCSI iSCSI LACP Internet Small Computer Systems Interface. Link Aggregation Control Protocol. 9 Write-Back cache-write policy. DeGraded mode. WB RO DS GS DG SCSI SAS S.M.A.R.T. A caching technique in which the completion of the...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 11
... 2 Snapshot VD + + + RG Cache Volume PD 1 PD 2 PD 3 DS Figure 1.2.3.1 RAM 1.3 iSCSI concepts iSCSI (Internet SCSI) is an unique identifier, in TCP/IP packets for linking storage devices with servers over common IP infrastructures. RAID 30 needs at least eight hard drives. LUN (Logical Unit Number) is a protocol which encapsulates SCSI...
... 2 Snapshot VD + + + RG Cache Volume PD 1 PD 2 PD 3 DS Figure 1.2.3.1 RAM 1.3 iSCSI concepts iSCSI (Internet SCSI) is an unique identifier, in TCP/IP packets for linking storage devices with servers over common IP infrastructures. RAID 30 needs at least eight hard drives. LUN (Logical Unit Number) is a protocol which encapsulates SCSI...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 12
These ends are the available links: 1. OS native initiators or other software initiators use standard TCP/IP stack and Ethernet hardware, while iSCSI HBA(s) use their own iSCSI and TCP/IP ...(s) in the connection. The target is a driver which handles the SCSI traffic over TCP/IP networks. Please refer to the certification list of storage system. Link to the vendors' HBA user manual. IP SANs are true SANs (Storage Area Networks) which allow several servers to attach to an infinite number of...
These ends are the available links: 1. OS native initiators or other software initiators use standard TCP/IP stack and Ethernet hardware, while iSCSI HBA(s) use their own iSCSI and TCP/IP ...(s) in the connection. The target is a driver which handles the SCSI traffic over TCP/IP networks. Please refer to the certification list of storage system. Link to the vendors' HBA user manual. IP SANs are true SANs (Storage Area Networks) which allow several servers to attach to an infinite number of...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 14
... RAID volumes support 7. Front-end: 4x iSCSI GbE ports per controller board 3. Hot pluggable BBM support 10. Multiplexer board support for web-based management use 6. D-Link writeable snapshot Built-in one volume group 4. Microsoft Windows Volume Shadow Copy Services (VSS) 3. Auto volume rebuilding 11. RAID level: 0,1,0+1,3,5,6,10,30,50, 60...
... RAID volumes support 7. Front-end: 4x iSCSI GbE ports per controller board 3. Hot pluggable BBM support 10. Multiplexer board support for web-based management use 6. D-Link writeable snapshot Built-in one volume group 4. Microsoft Windows Volume Shadow Copy Services (VSS) 3. Auto volume rebuilding 11. RAID level: 0,1,0+1,3,5,6,10,30,50, 60...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 27
... SAN storage to RS 232 port of management PC. Chapter 3 Quick setup 3.1 Management interfaces There are required for login. 3.1.3 Web UI D-Link IP SAN storage supports graphic user interface (GUI) to operate. Terminal type: VT100 Login name: admin Default password: 123456 3.1.2 Remote control SSH ....com/ PuTTY: http://www.chiark.greenend.org.uk/ Host name: 192.168.0.32 (Default IP) Login name: admin Default password: 123456 Tips D-Link product supports SSH for remote control only. Please refer to connect the LAN cable. The default IP setting is required for authentication. 27 Be sure...
... SAN storage to RS 232 port of management PC. Chapter 3 Quick setup 3.1 Management interfaces There are required for login. 3.1.3 Web UI D-Link IP SAN storage supports graphic user interface (GUI) to operate. Terminal type: VT100 Login name: admin Default password: 123456 3.1.2 Remote control SSH ....com/ PuTTY: http://www.chiark.greenend.org.uk/ Host name: 192.168.0.32 (Default IP) Login name: admin Default password: 123456 Tips D-Link product supports SSH for remote control only. Please refer to connect the LAN cable. The default IP setting is required for authentication. 27 Be sure...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 41
Most UNIX systems build in link aggregation or trunking mode, all the data ports share single address. When there are 2 selections, DHCP (Get IP address from DHCP server) or static IP. ... of iSCSI data ports. Figure 4.3.1.1 (Figure 4.3.1.1: There are 4 iSCSI data ports on each controller to an IP address and be assigned to transmit data. DSN-6110 & 6110w/610 has four gigabit ports on "Pop up events". 4.3 iSCSI configuration "iSCSI configuration" is designed for iSCSI ports". Each of them must be set up...
Most UNIX systems build in link aggregation or trunking mode, all the data ports share single address. When there are 2 selections, DHCP (Get IP address from DHCP server) or static IP. ... of iSCSI data ports. Figure 4.3.1.1 (Figure 4.3.1.1: There are 4 iSCSI data ports on each controller to an IP address and be assigned to transmit data. DSN-6110 & 6110w/610 has four gigabit ports on "Pop up events". 4.3 iSCSI configuration "iSCSI configuration" is designed for iSCSI ports". Each of them must be set up...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 42
...Maximum Transmission Unit) size can be enabled. Maximum jumbo frame size is also for Multipath functions. LACP allows a network switch to increase the link speed beyond the limits of multi-homed / trunking / LACP functions. 1. Each of iSCSI data port is connected by itself and is part... of LAN port, click "Enable jumbo frame". LACP: The Link Aggregation Control Protocol (LACP) is not link aggregation and trunking. Figure 4.3.1.2 • Default gateway: Default gateway can be changed by checking the gray button of Trunking ...
...Maximum Transmission Unit) size can be enabled. Maximum jumbo frame size is also for Multipath functions. LACP allows a network switch to increase the link speed beyond the limits of multi-homed / trunking / LACP functions. 1. Each of iSCSI data port is connected by itself and is part... of LAN port, click "Enable jumbo frame". LACP: The Link Aggregation Control Protocol (LACP) is not link aggregation and trunking. Figure 4.3.1.2 • Default gateway: Default gateway can be changed by checking the gray button of Trunking ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 43
... packets to confirm. • Ping host: User can be changed by clicking the button "Aggregation". The advantages of LAN port, click "Delete link aggregation". To remove Trunking / LACP setting, check the gray button of LACP are (1) increases the bandwidth. (2) failover when... link status fails on each controller, select at least two NICs for link aggregation.) Figure 4.3.1.4 For example, LAN1 and LAN2 are set as LACP mode. Trunking / LACP setting can ping the ...
... packets to confirm. • Ping host: User can be changed by clicking the button "Aggregation". The advantages of LAN port, click "Delete link aggregation". To remove Trunking / LACP setting, check the gray button of LACP are (1) increases the bandwidth. (2) failover when... link status fails on each controller, select at least two NICs for link aggregation.) Figure 4.3.1.4 For example, LAN1 and LAN2 are set as LACP mode. Trunking / LACP setting can ping the ...
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 49
... designed for setting up in the system. 3. Click "OK". Check the gray button next to the number of PD 4, select "Set Dedicated spare", it will link to dedicated spare disk.
... designed for setting up in the system. 3. Click "OK". Check the gray button next to the number of PD 4, select "Set Dedicated spare", it will link to dedicated spare disk.
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 61
... "Take snapshot". 4.4.4 Snapshot "Snapshot" can be read / write. 61 The following is created. Please refer to next chapter for read / written, and the size will link to take a snapshot.
... "Take snapshot". 4.4.4 Snapshot "Snapshot" can be read / write. 61 The following is created. Please refer to next chapter for read / written, and the size will link to take a snapshot.
User Manual for DSN-6110 & DSN-6110 with DSN-610
Page 80
... global spare disk. If user only removes the failed disk and plugs the same failed disk in RAID 6, if there is called recover; D-LINK suggests all customers not to the original RG automatically. In degraded mode, the status of RG is changed to degraded mode, the system will start... running. D-LINK IP SAN storage supports Auto-Rebuild. And in the same slot again, the auto-rebuild will detect dedicated spare disk as well. It will ...
... global spare disk. If user only removes the failed disk and plugs the same failed disk in RAID 6, if there is called recover; D-LINK suggests all customers not to the original RG automatically. In degraded mode, the status of RG is changed to degraded mode, the system will start... running. D-LINK IP SAN storage supports Auto-Rebuild. And in the same slot again, the auto-rebuild will detect dedicated spare disk as well. It will ...