Reference Guide
Page 2
... Information ...18 Password...18 i Table of Contents D-Link Web Smart Switch User Manual Table of Contents Table of Contents ...i About This Guide...1 Terms/Usage...1 Copyright and Trademarks ...1 1 Product Introduction ...2 DGS-1210-20 ...3 Front Panel ...3 Rear Panel...3 DGS-1210-28 ...3 Front Panel ...3 Rear Panel...4 DGS-1210-28P...4 Front Panel ...4 Rear Panel...4 DGS-1210-52 ...5 Front Panel ...5 Rear Panel...5 2 Hardware Installation ...6 Step...
... Information ...18 Password...18 i Table of Contents D-Link Web Smart Switch User Manual Table of Contents Table of Contents ...i About This Guide...1 Terms/Usage...1 Copyright and Trademarks ...1 1 Product Introduction ...2 DGS-1210-20 ...3 Front Panel ...3 Rear Panel...3 DGS-1210-28 ...3 Front Panel ...3 Rear Panel...4 DGS-1210-28P...4 Front Panel ...4 Rear Panel...4 DGS-1210-52 ...5 Front Panel ...5 Rear Panel...5 2 Hardware Installation ...6 Step...
Reference Guide
Page 4
... Ethernet Technology...85 Switching Technology ...85 Appendix B - Table of Contents D-Link Web Smart Switch User Manual L2 Functions > LLDP > LLDP Management Address ... LLDP Remote Port Table 49 L2 Functions > LLDP > LLDP Statistics 51 QoS > Bandwidth Control...52 QoS > 802.1p/DSCP ...52 Security > Trusted Host...53 Security > Port Security...54 Security > Traffic Segmentation ...54 Security ... ACL Profile List...62 ACL > ACL Finder ...65 PoE > PoE Global Settings (DGS-1210-28P only 65 PoE > PoE Port Settings (DGS-1210-28P only 66 SNMP > Trap to SmartConsole Utility...67 SNMP > SNMP > SNMP ...
... Ethernet Technology...85 Switching Technology ...85 Appendix B - Table of Contents D-Link Web Smart Switch User Manual L2 Functions > LLDP > LLDP Management Address ... LLDP Remote Port Table 49 L2 Functions > LLDP > LLDP Statistics 51 QoS > Bandwidth Control...52 QoS > 802.1p/DSCP ...52 Security > Trusted Host...53 Security > Port Security...54 Security > Traffic Segmentation ...54 Security ... ACL Profile List...62 ACL > ACL Finder ...65 PoE > PoE Global Settings (DGS-1210-28P only 65 PoE > PoE Port Settings (DGS-1210-28P only 66 SNMP > Trap to SmartConsole Utility...67 SNMP > SNMP > SNMP ...
Reference Guide
Page 6
... either the entities claiming the marks and names or their products. About This Guide D-Link Web Smart Switch User Manual About This Guide This guide provides instructions to install the D-Link Gigabit Web Smart Switch DGS-1210-20/28/28P/52, how to use of Microsoft Corporation. Other trademarks and trade names may appear slightly...
... either the entities claiming the marks and names or their products. About This Guide D-Link Web Smart Switch User Manual About This Guide This guide provides instructions to install the D-Link Gigabit Web Smart Switch DGS-1210-20/28/28P/52, how to use of Microsoft Corporation. Other trademarks and trade names may appear slightly...
Reference Guide
Page 10
...Link Web Smart Switch User Manual Power: The power port is where to a power source. When a port has an amber light, this port. 5 When it has a green light it is running on 10M or 100M. Fan: The Fan LED lights green when fans work well, and lights red when fans fail. DGS-1210-52...seconds to reset the Switch back to this indicates that the Switch is connected to connect the AC power cord. Front Panel Figure 1.2 - DGS-1210-52 Rear Panel Power: Connect the supplied AC power cable to the default settings. Blinking indicates that the port is running on 1000M. CAUTION: The...
...Link Web Smart Switch User Manual Power: The power port is where to a power source. When a port has an amber light, this port. 5 When it has a green light it is running on 10M or 100M. Fan: The Fan LED lights green when fans work well, and lights red when fans fail. DGS-1210-52...seconds to reset the Switch back to this indicates that the Switch is connected to connect the AC power cord. Front Panel Figure 1.2 - DGS-1210-52 Rear Panel Power: Connect the supplied AC power cable to the default settings. Blinking indicates that the port is running on 1000M. CAUTION: The...
Reference Guide
Page 81
... Smart Switch User Manual 6 Command Line Interface The D-Link Web Smart Switch allows a computer or terminal to perform some basic monitoring and configuration tasks by the switch IP address, eg. To connect a switch .... 2. CLI Commands: The Basic Switch commands in the Command Line Interface (CLI) are case-sensitive. The logon prompt will appear as shown below (DGS-1210-52>): DGS-1210-52 login: admin Password: DGS-1210-52> Figure 6.1 - Press Enter in the following table. Command Parameter ? Note that the user name and password are listed (along with the appropriate parameters...
... Smart Switch User Manual 6 Command Line Interface The D-Link Web Smart Switch allows a computer or terminal to perform some basic monitoring and configuration tasks by the switch IP address, eg. To connect a switch .... 2. CLI Commands: The Basic Switch commands in the Command Line Interface (CLI) are case-sensitive. The logon prompt will appear as shown below (DGS-1210-52>): DGS-1210-52 login: admin Password: DGS-1210-52> Figure 6.1 - Press Enter in the following table. Command Parameter ? Note that the user name and password are listed (along with the appropriate parameters...
Reference Guide
Page 82
...} logout ping reboot reset config save show ipif show switch upload { firmware_toTFTP tftp://ip-address/filename | cfg_toTFTP tftp://ipaddress/filename } DGS-1210-52> download Purpose Syntax Description Parameters To download and install a firmware, boot, or switch configuration file from a TFTP server. filename ...− The filename of the switch: DGS-1210-52> ? tftp://ip-address/ − The IP address of the switch. command displays a list of commands of the TFTP server. 6 Command Line Interface D-Link Web Smart Switch User Manual Each command is listed in ...
...} logout ping reboot reset config save show ipif show switch upload { firmware_toTFTP tftp://ip-address/filename | cfg_toTFTP tftp://ipaddress/filename } DGS-1210-52> download Purpose Syntax Description Parameters To download and install a firmware, boot, or switch configuration file from a TFTP server. filename ...− The filename of the switch: DGS-1210-52> ? tftp://ip-address/ − The IP address of the switch. command displays a list of commands of the TFTP server. 6 Command Line Interface D-Link Web Smart Switch User Manual Each command is listed in ...
Reference Guide
Page 83
...TFTP server. cfg_toTFTP − Specifies that the Switch's current settings will be uploaded to the TFTP server. 6 Command Line Interface D-Link Web Smart Switch User Manual Restrictions file is not at the root directory of the TFTP server. None. source URL tftp://1.1.1.23 ... configurations will be lost. filename − The filename of the firmware or switch configuration 78 Example usage: To download a firmware file: DGS-1210-52> download firmware_fromTFTP 1.1.1.23 1\dgs_1210-10032.ros 01-Jan-2000 01:19:48 %COPY-I-FILECPY: Files Copy - upload { firmware_toTFTP tftp://ip-...
...TFTP server. cfg_toTFTP − Specifies that the Switch's current settings will be uploaded to the TFTP server. 6 Command Line Interface D-Link Web Smart Switch User Manual Restrictions file is not at the root directory of the TFTP server. None. source URL tftp://1.1.1.23 ... configurations will be lost. filename − The filename of the firmware or switch configuration 78 Example usage: To download a firmware file: DGS-1210-52> download firmware_fromTFTP 1.1.1.23 1\dgs_1210-10032.ros 01-Jan-2000 01:19:48 %COPY-I-FILECPY: Files Copy - upload { firmware_toTFTP tftp://ip-...
Reference Guide
Page 84
6 Command Line Interface D-Link Web Smart Switch User Manual Restrictions Example usage: file on the Switch. source URL running-config destination URL tftp://1.1.1.23/1\running -config 01-Jan-2000 01:26:11 %COPY-I-FILECPY: Files Copy - To upload a firmware file: DGS-1210-52>upload firmware_toTFTP 1.1.1.23 1\...16 %COPY-W-TRAP: The copy operation was completed success fully ! 158 bytes copied in 00:00:05 [hh:mm:ss] DGS-1210-52> config ipif system Purpose Syntax Description Parameters Restrictions Example usage: To configure the System IP interface. logout 79 You need to ...
6 Command Line Interface D-Link Web Smart Switch User Manual Restrictions Example usage: file on the Switch. source URL running-config destination URL tftp://1.1.1.23/1\running -config 01-Jan-2000 01:26:11 %COPY-I-FILECPY: Files Copy - To upload a firmware file: DGS-1210-52>upload firmware_toTFTP 1.1.1.23 1\...16 %COPY-W-TRAP: The copy operation was completed success fully ! 158 bytes copied in 00:00:05 [hh:mm:ss] DGS-1210-52> config ipif system Purpose Syntax Description Parameters Restrictions Example usage: To configure the System IP interface. logout 79 You need to ...
Reference Guide
Page 85
... stack. If the Switch is reachable on the Switch's console. None. None. To ping the IP address 10.90.90.91: DGS-1210-52> ping 10.90.90.91 Reply Received From :10.90.90.91, TimeTaken : 20 msecs Reply Received From :10.90.90.91...msecs --- 10.90.90.91 Ping Statistics --3 Packets Transmitted, 3 Packets Received, 0% Packets Loss DGS-1210-52> reboot Purpose Syntax Description Parameters Restrictions To reboot the Switch. 6 Command Line Interface D-Link Web Smart Switch User Manual Description Parameters Restrictions The logout command terminates the current user's session on ...
... stack. If the Switch is reachable on the Switch's console. None. None. To ping the IP address 10.90.90.91: DGS-1210-52> ping 10.90.90.91 Reply Received From :10.90.90.91, TimeTaken : 20 msecs Reply Received From :10.90.90.91...msecs --- 10.90.90.91 Ping Statistics --3 Packets Transmitted, 3 Packets Received, 0% Packets Loss DGS-1210-52> reboot Purpose Syntax Description Parameters Restrictions To reboot the Switch. 6 Command Line Interface D-Link Web Smart Switch User Manual Description Parameters Restrictions The logout command terminates the current user's session on ...
Reference Guide
Page 86
...of the Switch's parameters to their default values: DGS-1210-52> reset config % Device will be reset to the default settings. 6 Command Line Interface D-Link Web Smart Switch User Manual Example usage: To restart the Switch: DGS-1210-52> reboot % Device will reboot, please wait a ...few minutes to the factory default settings. DGS-1210-52> reset config Purpose Syntax Description Parameters Restrictions To ...
...of the Switch's parameters to their default values: DGS-1210-52> reset config % Device will be reset to the default settings. 6 Command Line Interface D-Link Web Smart Switch User Manual Example usage: To restart the Switch: DGS-1210-52> reboot % Device will reboot, please wait a ...few minutes to the factory default settings. DGS-1210-52> reset config Purpose Syntax Description Parameters Restrictions To ...
Reference Guide
Page 87
...version System Protocol version : 1.00.000 : 2.001.004 System serial number MAC Address : 1MB1733K0000A : 00-18-E7-48-85-50 DGS-1210-52> config account admin password Purpose Syntax Description Parameters Restrictions Example usage: To display the configuration of the administrator. config account admin password The ... command sets the administrator password. − The new password of an IP interface on the Switch. 6 Command Line Interface D-Link Web Smart Switch User Manual show switch command displays the status of the switch. None. None. None. show switch The show...
...version System Protocol version : 1.00.000 : 2.001.004 System serial number MAC Address : 1MB1733K0000A : 00-18-E7-48-85-50 DGS-1210-52> config account admin password Purpose Syntax Description Parameters Restrictions Example usage: To display the configuration of the administrator. config account admin password The ... command sets the administrator password. − The new password of an IP interface on the Switch. 6 Command Line Interface D-Link Web Smart Switch User Manual show switch command displays the status of the switch. None. None. None. show switch The show...
Reference Guide
Page 88
...Link Web Smart Switch User Manual Description Parameters Restrictions The save Building configuration ... [OK] DGS-1210-52> debug info Purpose Syntax Description Parameters Restrictions Example usage: To display the ARP table and MAC FDB information of the Switch. debug info The debut info command displays the ARP table and MAC FDB of the Switch: DGS-1210-52.... None. Example usage: To save the Switch's current configuration to non-volatile RAM: DGS-1210-52> save command saves the configuration changes to the memory. To display the ARP table and MAC FDB information of the...
...Link Web Smart Switch User Manual Description Parameters Restrictions The save Building configuration ... [OK] DGS-1210-52> debug info Purpose Syntax Description Parameters Restrictions Example usage: To display the ARP table and MAC FDB information of the Switch. debug info The debut info command displays the ARP table and MAC FDB of the Switch: DGS-1210-52.... None. Example usage: To save the Switch's current configuration to non-volatile RAM: DGS-1210-52> save command saves the configuration changes to the memory. To display the ARP table and MAC FDB information of the...
Reference Guide
Page 89
6 Command Line Interface Total Mac Addresses displayed: 1 DGS-1210-52> D-Link Web Smart Switch User Manual 84
6 Command Line Interface Total Mac Addresses displayed: 1 DGS-1210-52> D-Link Web Smart Switch User Manual 84
Reference Guide
Page 91
... supported - Supports at least 64 static multicast groups 802.1D Spanning Tree 802.1w Rapid Spanning Tree Loopback Detection 802.3ad Link Aggregation: - DGS-1210-20: 40Gbps - DGS-1210-28P: 56Gbps - DGS-1210-28: 41.7Mpps - DGS-1210-52: 47.1dB (2 Smart Fan) Operation Temperature 0~50°C Storage Temperature -20~70°C Operation Humidity: 0%~95% RH Storage Humidity: 0%~95% RH...
... supported - Supports at least 64 static multicast groups 802.1D Spanning Tree 802.1w Rapid Spanning Tree Loopback Detection 802.3ad Link Aggregation: - DGS-1210-20: 40Gbps - DGS-1210-28P: 56Gbps - DGS-1210-28: 41.7Mpps - DGS-1210-52: 47.1dB (2 Smart Fan) Operation Temperature 0~50°C Storage Temperature -20~70°C Operation Humidity: 0%~95% RH Storage Humidity: 0%~95% RH...
Reference Guide
Page 92
...Each port on the system can be turned on/off by schedule. ICMP - IPv4 address - SSL: Support v1/v2/v3 Smart Binding - DGS-1210-20/28/28P: 200 rules (each rule can be associated to configure 5 IP addresses for DHCP server. VLAN 802.1Q VLAN standard (VLAN ... default, ARP and IP packet inspection as an option. - DGS-1210-52: 450 rules 87 In this mode, switches save power when the switch port link is minimal. Technical Specifications D-Link Web Smart Switch User Manual LLDP L2 Multicast Filtering D-Link Green Technology Power Saving: Enabled by schedule. - By Cable ...
...Each port on the system can be turned on/off by schedule. ICMP - IPv4 address - SSL: Support v1/v2/v3 Smart Binding - DGS-1210-20/28/28P: 200 rules (each rule can be associated to configure 5 IP addresses for DHCP server. VLAN 802.1Q VLAN standard (VLAN ... default, ARP and IP packet inspection as an option. - DGS-1210-52: 450 rules 87 In this mode, switches save power when the switch port link is minimal. Technical Specifications D-Link Web Smart Switch User Manual LLDP L2 Multicast Filtering D-Link Green Technology Power Saving: Enabled by schedule. - By Cable ...