User Guide
Page 8
... Numbers, π, and Permutation/Combination 20 kAngle Unit Conversion 21 kCoordinate Conversion (Pol (x, y), Rec (r 21 kEngineering Notation Calculations 22 Equation Calculations 22 kQuadratic and Cubic Equations 22 kSimultaneous Equations 24 Statistical Calculations 26 Standard Deviation 26 Regression Calculations 28 Technical Information 32 kWhen you have a problem 32 kError Messages 32 kOrder of Operations 34 kStacks 35...
... Numbers, π, and Permutation/Combination 20 kAngle Unit Conversion 21 kCoordinate Conversion (Pol (x, y), Rec (r 21 kEngineering Notation Calculations 22 Equation Calculations 22 kQuadratic and Cubic Equations 22 kSimultaneous Equations 24 Statistical Calculations 26 Standard Deviation 26 Regression Calculations 28 Technical Information 32 kWhen you have a problem 32 kError Messages 32 kOrder of Operations 34 kStacks 35...
User Guide
Page 9
.... • The lower line shows the result. A separator symbol is displayed every three digits when the integer part of equations F F 1 EQN 7 fx-95MS Modes To perform this type of calculation: Perform this To enter key operation: this mode: Basic arithmetic calculations F 1 COMP Standard deviation F 2 SD Regression calculations F 3 REG Solution of the mantissa has more than three digits...
.... • The lower line shows the result. A separator symbol is displayed every three digits when the integer part of equations F F 1 EQN 7 fx-95MS Modes To perform this type of calculation: Perform this To enter key operation: this mode: Basic arithmetic calculations F 1 COMP Standard deviation F 2 SD Regression calculations F 3 REG Solution of the mantissa has more than three digits...
User Guide
Page 28
...the key sequence shown below. S • Input data is indicated on the display (n value). 54 S 51 S 55 S 53 S S 54 S 52 S Sample Standard Deviation (σnҀ1) = 1.407885953 A X 3 = 26 Each time you press S to calculate values for the following data : 55, 54, 51, 55, 53, 53,... 54, 52 In the SD Mode: A B 1 (Scl) = (Stat clear) 55 S n= SD 1. tions noted nearby. SD F 2 (fx-95MS) F F 1 (Other Models)...
...the key sequence shown below. S • Input data is indicated on the display (n value). 54 S 51 S 55 S 53 S S 54 S 52 S Sample Standard Deviation (σnҀ1) = 1.407885953 A X 3 = 26 Each time you press S to calculate values for the following data : 55, 54, 51, 55, 53, 53,... 54, 52 In the SD Mode: A B 1 (Scl) = (Stat clear) 55 S n= SD 1. tions noted nearby. SD F 2 (fx-95MS) F F 1 (Other Models)...
User Guide
Page 29
... also means that shown above , scrolling through data you want to perform some other operation (calculation, recall of statistical calculation results, etc.), you should always press the t key first to exit data display. • Pressing the S key instead of = after inputting data is complete, you can...or after changing a value on the display registers the value you input as a new data item, and leaves the old value as it to be able to input any order, and not necessarily that if you want . Ed i t OFF ESC 1 2 27 Population Standard Deviation (σn) = 1.316956719 Arithmetic Mean ...
... also means that shown above , scrolling through data you want to perform some other operation (calculation, recall of statistical calculation results, etc.), you should always press the t key first to exit data display. • Pressing the S key instead of = after inputting data is complete, you can...or after changing a value on the display registers the value you input as a new data item, and leaves the old value as it to be able to input any order, and not necessarily that if you want . Ed i t OFF ESC 1 2 27 Population Standard Deviation (σn) = 1.316956719 Arithmetic Mean ...