CS650 and CS655 Water Content Reflectometers - Page 1
INSTRUCTION MANUAL
CS650 and CS655 Water Content Reflectometers
Revision: 2/14
Copyright © 2011-2014 Campbell Scientific, Inc.
CS650 and CS655 Water Content Reflectometers - Page 3
... improper service, accidents of Campbell's product warranty. Warranty
"PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. Products not manufactured, but that are re-sold by Campbell, are warranted by Campbell Scientific, Inc. ("Campbell") to the limits extended by Campbell such as programming to customer specifications, electrical connections to repairing or replacing (at Campbell's option...
CS650 and CS655 Water Content Reflectometers - Page 4
..., Utah 84321-1784
For all returns, the customer must be either emailed to repair@campbellsci.com or faxed to contaminants that may not be returned without prior authorization. Campbell Scientific reserves the right to refuse service on the outside of the problem, an RMA number will be issued. To obtain a Returned Materials Authorization (RMA), contact...
CS650 and CS655 Water Content Reflectometers - Page 6
...
8. Troubleshooting 34
11. Discussion of Soil Electrical Conductivity 26 7.4 Error Sources in Water Content Reflectometer Measurement .......... 27 7.4.1 Probe-to 1 B-5 B-3. CS650 and CS655 average ...1 and changing SDI-12 address from 0 to -PC Interface 11 B-1. B-8
ii SDI-12 Sensor Support B-1
B.1 SDI-12 Command Basics B-1 B.2 Changing the SDI-12 Address Using Terminal Emulator and a
...
CS650 and CS655 Water Content Reflectometers - Page 9
Unless specifically stated otherwise, information in the manual applies equally to reference model numbers CS650 and CS655. Overview
The CS650 measures ...and temperature. Before installing the sensor, please study
• Section 2, Cautionary Statements • Section 3, Initial Inspection
2. File damage claims with the shipping company.
• The model number and cable length...
CS650 and CS655 Water Content Reflectometers - Page 10
...a water content reflectometer, with SDI-12 recorders, including Campbell Scientific dataloggers. A differential oscillator circuit is measured with a thermistor...estimate volumetric water content. The CS650 handles this problem by exciting the rods with a known nonpolarizing ...the probe stainless-steel rods. CS650 and CS655 Water Content Reflectometers
FIGURE 4-1. Electrical conductivity is...
CS650 and CS655 Water Content Reflectometers - Page 11
... A200 USB-to theWireless Sensor Manual for a wide range of our CS655; Campbell Scientific also offers the CS650-LC, CS655-LC, and CWS655. refer to -Serial Module allows RS-232 serial communication between a computer and the CS650 by means of RS-232 Tx/Rx.
Specifications
Features:
• Larger sample volume reduces error
• Measurement corrected for effects...
CS650 and CS655 Water Content Reflectometers - Page 17
...) software.
6.4.1 Using the A200
6.4.1.1 Driver Installation
If the A200 has not been previously plugged into your PC and your PC.
9
TABLE 6-2. Device Configuration Utility software uses RS-232 to communicate with devices other than Campbell Scientific dataloggers, use with a CS650 using SDI-12.
6.3.2 RS-232 Wiring
TABLE 6-2 shows the wiring code for RS-232 and...
CS650 and CS655 Water Content Reflectometers - Page 19
.... CS650 and CS655 Water Content Reflectometers
FIGURE 6-2. Launch DevConfig and select "CS650 Series" from the Baud Rate drop-down menu.
11 Connect the CS650 to the A200 USB port with the supplied USB cable. A200 Sensor-to-PC Interface
6.4.2 Device Configuration Utility (DevConfig)
DevConfig may be downloaded from the Campbell Scientific website, www...
CS650 and CS655 Water Content Reflectometers - Page 26
... instruction P105 SDI-12 Recorder.
aM3! aM1! aI! aM2! SDI-12 communication is established using multiplexers, the simplest configuration is the sensor address) aM!
When multiplexing CS650 probes, the switched 12V channel should be used to connect up to 32 CS650 probes to the same datalogger control port as long as Campbell Scientific...
CS650 and CS655 Water Content Reflectometers - Page 35
... over the range of the measurement.
CS650 and CS655 Water Content Reflectometers
7.4 Error Sources in Water Content Reflectometer Measurement
7.4.1 Probe-to-Probe Variability Error
All manufactured CS650s/CS655s are checked in °C, and θ is the volumetric water content value at soil temperature T.
27 Campbell Scientific offers the CS650G insertion tool.
7.5 Temperature Dependence...
CS650 and CS655 Water Content Reflectometers - Page 42
...Troubleshooting
Symptom
All CS650 output values read 0
Possible Cause
No SDI12Recorder instruction in datalogger program
Change probe address or modify program so that control port high.
SW12V channel not turning on
If using SW 12V on a CR10X, ensure that a wire connects a control port to SW12V CTRL and the program sets...CS650, try CS655
Readings erratic,...range
soil specific calibration
...
CS650 and CS655 Water Content Reflectometers - Page 47
... are addressed with the address, a.
Sensors with (carriage return -
CS650 SDI-12 Command and Response Set
Name Acknowledge Active Send Identification
Change Address Address Query Start Measurement Send Data
Additional Measurements
Command Response
a! SDI-12 commands supported by alphanumeric qualifiers. aM! The sensor replies to the query with the last digit of...
CS650 and CS655 Water Content Reflectometers - Page 48
... sensor specific information may also be returned when one or more subsequent D! Permittivity (ε), Bulk Electrical Conductivity (σ), Temperature (°C) M2! SDI-12 Sensor Support
Change...313CampbellCS65X 000Std.00.35=2196405 where: Address = 3 SDI-12 version =1.3 Manufacturer = Campbell Sensor model = CS65X OS version = 000Std.00.35 Sensor serial number = 2196405
Start Measurement ...
CS650 and CS655 Water Content Reflectometers - Page 49
...with the datalogger through Campbell Scientific datalogger support software, but is the new address. SDI-12 Sensor Support
Aborting a Measurement ...to a single datalogger control port. command is in troubleshooting SDI-12 systems because it is sent to the...Device Configuration Utility. The current address can manually interrogate and enter settings in the Connect screen of 0-9, a-z, ...