Campbell Scientific CS100 Support and Manuals

Get Help and Manuals for this Campbell Scientific item

View All Support Options Below
Free Campbell Scientific CS100 manuals!
Problems with Campbell Scientific CS100?

Ask a Question

Popular Campbell Scientific CS100 Manual Pages

CS100 Barometric Pressure Sensor - Page 3

...to repairing or replacing (at Campbell's ...service for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by the original manufacturer. Campbell will return such products best way CIP (Port of Campbell's product warranty. Warranty "PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. Campbell is part...
CS100 Barometric Pressure Sensor - Page 4

... Logan, Utah 84321-1784 For all returns, the customer must be returned without prior authorization. Campbell Scientific reserves the right to refuse service on products that were exposed to contaminants that may not be either emailed to repair@campbellsci.com or faxed to process any returns until we receive this number clearly on the...
CS100 Barometric Pressure Sensor - Page 7

... backplates of the cable is suspected, consult with all Campbell Scientific dataloggers. Local fire codes may damage the CS100 beyond repair. • Care should be taken when opening the ... for damage. and will support combustion in environmental applications, the CS100 is compatible with a Campbell Scientific applications engineer. • Although the CS100 is rated as slow burning...
CS100 Barometric Pressure Sensor - Page 8

... the pressure cavity, and also to use Campbell Scientific's SCWin Short Cut Program Generator. 1. Open Short Cut and click on New Program. 2. Select a datalogger and scan interval. 2 Use SCWin Short Cut to Program Datalogger and Generate Wiring Diagram The simplest method for programming the datalogger to measure the CS100 is to ensure that water cannot enter...
CS100 Barometric Pressure Sensor - Page 11

...manuals for ordering these special versions. Please contact Campbell Scientific, Inc. for more information. If the CS100 and datalogger will be housed in the applied pressure, which the datalogger...measured by a Campbell Scientific datalogger. CS100 Barometric Pressure Sensor isolated metallic surfaces. The analog signal generated by Setra's custom Application Specific Integrated Circuit (...
CS100 Barometric Pressure Sensor - Page 12

CS100 Barometric Pressure Sensor 6. Specifications Features: • Integral switching circuit limits power consumption to measurement cycle • Compatible with all Campbell Scientific dataloggers (including the CR200(X) series) • Calibration NIST traceable • Meets CE conformance standards Compatibility Dataloggers: CR200(X) series CR800 series CR1000 CR3000 CR5000 CR9000...
CS100 Barometric Pressure Sensor - Page 13

CS100 Barometric Pressure Sensor 6.1.2 Performance for "500 to 1100 mb" Range Option Measurement Range: Total Accuracy2: Linearity: Hysteresis: Repeatability: 500 to 1100 mb ±0.6 mb @ 20&#...
CS100 Barometric Pressure Sensor - Page 14

... for situations where it is typically mounted in a Campbell Scientific enclosure next to house the CS100 in . The CS100 is desirable to the datalogger. enclosure that can house one CS100 8 ENC100 is a 6.7-in its own enclosure. FIGURE 7-1. x 3.7-in permanent damage. Installation 7.1 Enclosure Considerations To prevent condensation, install the sensor in . The ENC100 is...
CS100 Barometric Pressure Sensor - Page 15

... 7-2. Enclosures purchased from Campbell Scientific properly vent to make the hole on the outer wall. Proper wiring is shown in pressure. 7.2 Wiring 7.2.1 Datalogger Connection Before connecting the barometer to the datalogger, a yellow warning label must vent to the datalogger. For user-supplied enclosures, it can cause transient changes in TABLE 7-1. CS100 as wind blowing...
CS100 Barometric Pressure Sensor - Page 17

...(Z=X*F) instruction for CR500, CR510, CR10(X), CR23X, 21X, and CR7, or by adding an expression for CR200(X), CR800, CR850, CR1000, CR3000, CR5000, and CR9000(X) dataloggers. ...Atmospheric pressure changes little with time. See TABLE 7-2 below for proper multipliers and offsets. TABLE 7-3. CS100 Barometric Pressure Sensor 7.3 Programming The CS100...
CS100 Barometric Pressure Sensor - Page 18

... CRBasic dataloggers, such as the CR200(X), CR800, CR850, CR3000, and CR9000(X) are shown in TABLE 7-4 below. In the example, the CR1000 measures the CS100 once an hour. To do this, the CR1000 uses a control port to turn on the CS100 one minute before the top of the hour. CS100 Barometric Pressure Sensor 7.3.3 Program Examples The CS100 wiring instructions...
CS100 Barometric Pressure Sensor - Page 19

... an hour in a pipeline mode, the measurement instruction is placed outside the "If" statement VoltSE (CS100_temp,1,mV2500,15,False,200,250,0.2,600) 'Turn on one minute before the hour, the CS100 starts to a current variable called "pressure", and the sensor is turned off immediately. 'CR1000 Datalogger Public CS100_temp Public pressure Units pressure = mbar DataTable...
CS100 Barometric Pressure Sensor - Page 20

...) (P1) 1: 1 2: 15 3: 6 4: 1 5: 0.2 6: 600 Reps 2500 mV Fast Range SE Channel Loc [ P_mb ] Multiplier Offset ;Turn off CS100 ; 4: Do (P86) 1: 58* Set Port 8* Low 5: End (P95) 6: If time is for a CR10X, other Edlog dataloggers, such as above) 3: 10 Set Output Flag High (Flag 0) 7: Real Time (P77) 1: 0110 Day,Hour/Minute (midnight = 0000) ;Store in high...
CS100 Barometric Pressure Sensor - Page 21

...for the CR800, CR850, CR1000, CR3000, CR5000, and CR9000(X) dataloggers or using the Resolution (P78) instruction for Campbell Scientific dataloggers is stored to find the difference in the measurement instruction. V. Hobbes, 1977: ... default resolution (low resolution) for our Edlog dataloggers. If you either need to deduct a fixed offset from the CS100 to a data table or to avoid losing ...
CS100 Barometric Pressure Sensor - Page 22

... from Campbell Scientific, Inc. Should you lose the five terminal connector (p/n 16004), the replacement part can ...Campbell Scientific, Inc. (435-227-9000) for an RMA number before returning the sensor for recalibration. Contact Campbell Scientific, Inc. CS100 Barometric Pressure Sensor The value dP is in millibars and the site elevation, E, is in the measurement instruction...

Campbell Scientific CS100 Reviews

Do you have an experience with the Campbell Scientific CS100 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Popular Campbell Scientific CS100 Search Terms

The following terms are frequently used to search for Campbell Scientific CS100 support:

Ask a New Question
Use the box below to post a new question about Campbell Scientific CS100.
Manuals / Documents
Download any of our Campbell Scientific CS100 manuals for free!

We have the following 1 documents available for the Campbell Scientific CS100:
  • CS100 Barometric Pressure Sensor
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific CS100 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific CS100 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.