Shipping Document
Page 5
...Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire,and the voltage retention is not applicable to test batteries at ambient temperature(20±5 ). SANYO Internal Procedure: As above. UN Test Data (Model:3UR18650-2-T0590) 1.Test Item: Altitude simulation (T1) 2.Test... Purpose: This test simulates air transport under low-pressure conditions. 3.Test Procedure: Test cells and batteries shall be stored at a pressure of 11.6kPa or less for at least six hours at fully discharged states. 5.Test Date: 2007...
...Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire,and the voltage retention is not applicable to test batteries at ambient temperature(20±5 ). SANYO Internal Procedure: As above. UN Test Data (Model:3UR18650-2-T0590) 1.Test Item: Altitude simulation (T1) 2.Test... Purpose: This test simulates air transport under low-pressure conditions. 3.Test Procedure: Test cells and batteries shall be stored at a pressure of 11.6kPa or less for at least six hours at fully discharged states. 5.Test Date: 2007...
Shipping Document
Page 6
... and no fire PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS SANYO Internal Procedure: As above. For large cells and batteries the duration of exposure to the test temperature extremes should be stored for 24 hours at least 12 hours. The test is conducted using rapid... and extreme temperature changes. 3.Test Procedure: Test cells and batteries are to be stored for at least six hours at a test temperature equal to 75±2 , followed by storage for at least six hours at...
... and no fire PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS SANYO Internal Procedure: As above. For large cells and batteries the duration of exposure to the test temperature extremes should be stored for 24 hours at least 12 hours. The test is conducted using rapid... and extreme temperature changes. 3.Test Procedure: Test cells and batteries are to be stored for at least six hours at a test temperature equal to 75±2 , followed by storage for at least six hours at...
Shipping Document
Page 7
...peak acceleration of 1gn is maintained until the frequency is then maintained at fully discharged states. 5.Test Date: 2007/10/19 6.Test Data Battery No. The amplitude is increased to 200Hz. UN Test Data (Model:3UR18650-2-T0590) 1.Test Item: Vibration (T3) P.5/10 2.Test Purpose...fire,and the voltage retention is as to faithfully transmit the vibration. One of the directions of vibration must be perpendicular to test batteries at 0.8 mm(1.6 mm total excursion) and thefrequency increased until a peak acceleration of 8gn occurs (approximately 50Hz).A peak acceleration of...
...peak acceleration of 1gn is maintained until the frequency is then maintained at fully discharged states. 5.Test Date: 2007/10/19 6.Test Data Battery No. The amplitude is increased to 200Hz. UN Test Data (Model:3UR18650-2-T0590) 1.Test Item: Vibration (T3) P.5/10 2.Test Purpose...fire,and the voltage retention is as to faithfully transmit the vibration. One of the directions of vibration must be perpendicular to test batteries at 0.8 mm(1.6 mm total excursion) and thefrequency increased until a peak acceleration of 8gn occurs (approximately 50Hz).A peak acceleration of...
Shipping Document
Page 8
..., F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire,and the voltage retention is not less than 90%. Each cell or battery shall be subjected to a half-sine shock of peak acceleration of 50 g n and pulse duration of 11 milliseconds. Each cell or... (Model:3UR18650-2-T0590) 1.Test Item: Shock (T4) P.6/10 2.Test Purpose: This test simulates possible impacts during transport. 3.Test Procedure: Test cells and batteries shall be secured to the testing machine by three shocks in the negative direction of three mutually perpendicular mounting positions of the cell or...
..., F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fire,and the voltage retention is not less than 90%. Each cell or battery shall be subjected to a half-sine shock of peak acceleration of 50 g n and pulse duration of 11 milliseconds. Each cell or... (Model:3UR18650-2-T0590) 1.Test Item: Shock (T4) P.6/10 2.Test Purpose: This test simulates possible impacts during transport. 3.Test Procedure: Test cells and batteries shall be secured to the testing machine by three shocks in the negative direction of three mutually perpendicular mounting positions of the cell or...
Shipping Document
Page 9
...PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS The cell or battery must be observed for a further six hours for at least one hour after the cell or battery external case temperature has returned to 55±2 . SANYO Internal Procedure: As above. 4.Test... for the test to be subjected to a short circuit condition with a total external resistance of this test. 5.Test Date: 2007/10/25 6.Test Data Battery No. UN Test Data (Model:3UR18650-2-T0590) 1.Test Item: External short circuit (T5) P.7/10 2.Test Purpose: This test simulates an external short circuit...
...PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS The cell or battery must be observed for a further six hours for at least one hour after the cell or battery external case temperature has returned to 55±2 . SANYO Internal Procedure: As above. 4.Test... for the test to be subjected to a short circuit condition with a total external resistance of this test. 5.Test Date: 2007/10/25 6.Test Data Battery No. UN Test Data (Model:3UR18650-2-T0590) 1.Test Item: External short circuit (T5) P.7/10 2.Test Purpose: This test simulates an external short circuit...
Shipping Document
Page 10
... axis parallel to the flat surface and perpendicular to the longitudinal axis of the 15.8mm diameter curved surface lying across the center of test batteries does not exceed 170°C and there is no disassembly and no fire A 15.8mm diameter bar is to be impacted with its center. A 9.1kg...
... axis parallel to the flat surface and perpendicular to the longitudinal axis of the 15.8mm diameter curved surface lying across the center of test batteries does not exceed 170°C and there is no disassembly and no fire A 15.8mm diameter bar is to be impacted with its center. A 9.1kg...
Shipping Document
Page 11
... is not more than 18V,the minimum voltage of the test shall be the lesser of two times the maximum charge voltage of the battery or 22V. (b) when the manufacturer's recommended charge voltage is no disassembly and no fire UN Test Data (Model:3UR18650-2-T0590) 1.Test... Item:Overcharge (T7) P.9/10 2.Test Purpose: This test evaluates the ability of a rechargeable battery to be conducted at ambient temperature. SANYO Internal Procedure: Min.Charge Voltage: 22 V Charge Current: 6.44 A 4.Test Requirements: There is more than...
... is not more than 18V,the minimum voltage of the test shall be the lesser of two times the maximum charge voltage of the battery or 22V. (b) when the manufacturer's recommended charge voltage is no disassembly and no fire UN Test Data (Model:3UR18650-2-T0590) 1.Test... Item:Overcharge (T7) P.9/10 2.Test Purpose: This test evaluates the ability of a rechargeable battery to be conducted at ambient temperature. SANYO Internal Procedure: Min.Charge Voltage: 22 V Charge Current: 6.44 A 4.Test Requirements: There is more than...
Shipping Document
Page 12
...after): 9.0kg SANYO confidential Copyright (c) 2008, Sanyo Electric Co., Ltd. It may do the drop of impact. No any cell damege and battery damage. 6-3. No any package crack 6-2. Where more than flat drops the centre of gravity must be vertically over the point of five orientations with...6-4. Number of test samples: Five(one for each drop). No any orientation without damage to cells or batteries contained therein, without shifting of the contents so as to allow battery to battery (or cell to result in the shape of a box. UN Test Data (Model:3UR18650-2-T0590) 1.Test...
...after): 9.0kg SANYO confidential Copyright (c) 2008, Sanyo Electric Co., Ltd. It may do the drop of impact. No any cell damege and battery damage. 6-3. No any package crack 6-2. Where more than flat drops the centre of gravity must be vertically over the point of five orientations with...6-4. Number of test samples: Five(one for each drop). No any orientation without damage to cells or batteries contained therein, without shifting of the contents so as to allow battery to battery (or cell to result in the shape of a box. UN Test Data (Model:3UR18650-2-T0590) 1.Test...