Owner Manual
Page 3
... have all of the following : ➤ Date of purchase ➤ Your full name and address ➤ Authorized dealer's company name and address ➤ Type of alarm installed ➤ Year, make, model and color of the automobile ➤ Automobile license number ➤ Vehicle identification number ➤ All security options installed on how...
... have all of the following : ➤ Date of purchase ➤ Your full name and address ➤ Authorized dealer's company name and address ➤ Type of alarm installed ➤ Year, make, model and color of the automobile ➤ Automobile license number ➤ Vehicle identification number ➤ All security options installed on how...
Owner Manual
Page 7
Transmit 13. Receive 15. Vibrator 6. Trunk 22. Shock sensor * Optional sensors. Battery level indicator 2. Remote start (option) 3. Garage door (519H2 option) 17. Ignition 7. Alarm 19. Arm 11. Disarm 12. Additional parts and labor required 2 © 2006 directed electronics Field disturbance sensor * 4. Vehicle number 9. Glass breakage sensor * 23. Ultrasonic sensor * ...
Transmit 13. Receive 15. Vibrator 6. Trunk 22. Shock sensor * Optional sensors. Battery level indicator 2. Remote start (option) 3. Garage door (519H2 option) 17. Ignition 7. Alarm 19. Arm 11. Disarm 12. Additional parts and labor required 2 © 2006 directed electronics Field disturbance sensor * 4. Vehicle number 9. Glass breakage sensor * 23. Ultrasonic sensor * ...
Owner Manual
Page 15
...and Icons The above Warn Away® displays when a security feature has been tripped, but not to a full alarm condition. Icon The tilt sensor icon will display for full alarm by 10 © 2006 directed electronics Icon The trunk icon will display for use with optional 519H2. and Icons...until the page is cleared. Icon The glass breakage sensor icon will display for full alarm by flashing for a few seconds and then display continuously until the page is in Warn Away® or alarm state. Icon The ultrasonic sensor (detects motion within the vehicle) icon will display when...
...and Icons The above Warn Away® displays when a security feature has been tripped, but not to a full alarm condition. Icon The tilt sensor icon will display for full alarm by 10 © 2006 directed electronics Icon The trunk icon will display for use with optional 519H2. and Icons...until the page is cleared. Icon The glass breakage sensor icon will display for full alarm by flashing for a few seconds and then display continuously until the page is in Warn Away® or alarm state. Icon The ultrasonic sensor (detects motion within the vehicle) icon will display when...
Owner Manual
Page 16
...icon displays when the vehicle is being remote started. Icon The shock sensor "sensor" icon will display for both Warn Away® and full alarm by displaying continuously until the page is cleared. © 2006 directed electronics 11 Icon The shock sensor icon will display for both Warn Away®...; and full alarm by flashing for both Warn Away® and full alarm by flashing for a few seconds and then display continuously until the page is cleared. Icon The shock sensor bar ...
...icon displays when the vehicle is being remote started. Icon The shock sensor "sensor" icon will display for both Warn Away® and full alarm by displaying continuously until the page is cleared. © 2006 directed electronics 11 Icon The shock sensor icon will display for both Warn Away®...; and full alarm by flashing for both Warn Away® and full alarm by flashing for a few seconds and then display continuously until the page is cleared. Icon The shock sensor bar ...
Owner Manual
Page 17
... display continuously until number 1 is programmed for vibrator notification (see programming LCD remote section of the guide). If a Warn Away® or alarm trigger should occur at one of 4 vehicles) being controlled by the remote. Icon The vehicle icon always displays the current vehicle (maximum of ...the other vehicles, that vehicle's number will be displayed and the LCD will display that vehicle's status. Now you can operate the alarm system on the display. Icon The vibrator icon will always display if the remote is displayed. To change back to the original vehicle selected...
... display continuously until number 1 is programmed for vibrator notification (see programming LCD remote section of the guide). If a Warn Away® or alarm trigger should occur at one of 4 vehicles) being controlled by the remote. Icon The vehicle icon always displays the current vehicle (maximum of ...the other vehicles, that vehicle's number will be displayed and the LCD will display that vehicle's status. Now you can operate the alarm system on the display. Icon The vibrator icon will always display if the remote is displayed. To change back to the original vehicle selected...
Owner Manual
Page 18
Icon The door icon will display for full alarm by flashing for a few seconds and then display continuously until the page is armed. Icon The arm icon will flash when the system is unlocking the doors and display continuously until the system is cleared. Icon The disarm icon will flash when the system is locking the doors and display continuously until the system is disarmed. © 2006 directed electronics 13
Icon The door icon will display for full alarm by flashing for a few seconds and then display continuously until the page is armed. Icon The arm icon will flash when the system is unlocking the doors and display continuously until the system is cleared. Icon The disarm icon will flash when the system is locking the doors and display continuously until the system is disarmed. © 2006 directed electronics 13
Owner Manual
Page 19
... transceiver. When the remote control receives a page it possible to assign any transmitter button to the remote control as confirmation of receipt of a command or alarm system status. The transmitter initially comes programmed with twoway communication. ➜ system signal paging features A page is sent and received, the system will display the...
... transceiver. When the remote control receives a page it possible to assign any transmitter button to the remote control as confirmation of receipt of a command or alarm system status. The transmitter initially comes programmed with twoway communication. ➜ system signal paging features A page is sent and received, the system will display the...
Owner Manual
Page 20
... remote control will not send a command to the remote control. The next time a button is pressed on the remote control. Alarm Page If the alarm system is triggered while armed, an Alarm Page will be performed at this time; The remote will beep and or vibrate every 60 seconds to receive the command... responds with 3 set to the incorrect vehicle or is beyond the range of the vehicle to alert the user that the alarm system was triggered and will continue until the alarm page is a series of 5 groups of 2 quick beeps and the icon will generate beeps and-or vibration. it will send a ...
... remote control will not send a command to the remote control. The next time a button is pressed on the remote control. Alarm Page If the alarm system is triggered while armed, an Alarm Page will be performed at this time; The remote will beep and or vibrate every 60 seconds to receive the command... responds with 3 set to the incorrect vehicle or is beyond the range of the vehicle to alert the user that the alarm system was triggered and will continue until the alarm page is a series of 5 groups of 2 quick beeps and the icon will generate beeps and-or vibration. it will send a ...
Owner Manual
Page 22
door unlocked, engine started, vehicle violation, etc.). Note: If programmed Off, no alarms will be notified to notify the user of inactivity and will be programmed to the remote. The LCD backlight will not give any notification that a ... The remote control can be notified to select page On/Off. When programmed off the remote will illuminate when a remote button is pressed, or an alarm status page is page Off. One beep is page On, Two beeps is received. Command information (armed/disarmed) will emit 2 long beep. © 2006 directed...
door unlocked, engine started, vehicle violation, etc.). Note: If programmed Off, no alarms will be notified to notify the user of inactivity and will be programmed to the remote. The LCD backlight will not give any notification that a ... The remote control can be notified to select page On/Off. When programmed off the remote will illuminate when a remote button is pressed, or an alarm status page is page Off. One beep is page On, Two beeps is received. Command information (armed/disarmed) will emit 2 long beep. © 2006 directed...
Owner Manual
Page 25
... be selected as opening a door. ➤ The optional starter kill prevents the vehicle's starter from cranking. ➤ Any full trigger of the alarm system will immediately send an alarm page to your remote informing you that the system is immediately closed). ➤ Turning on the ignition key will activate the MultiLevel Security...
... be selected as opening a door. ➤ The optional starter kill prevents the vehicle's starter from cranking. ➤ Any full trigger of the alarm system will immediately send an alarm page to your remote informing you that the system is immediately closed). ➤ Turning on the ignition key will activate the MultiLevel Security...
Owner Manual
Page 27
...a diagnostic notification as a reminder. If disarming after the system has been triggered, the remote control will indicate which sensor (5flashes) tripped the alarm. 2. These diagnostic notifications are: 1. If a sensor triggered the system, the remote will emit 4 quick beeps and the LCD screen will indicate... which switch (5-flashes) tripped the alarm. 3. If the system was triggered so many times that NPC is active the remote will emit the above notifications with 2 beeps and 5...
...a diagnostic notification as a reminder. If disarming after the system has been triggered, the remote control will indicate which sensor (5flashes) tripped the alarm. 2. These diagnostic notifications are: 1. If a sensor triggered the system, the remote will emit 4 quick beeps and the LCD screen will indicate... which switch (5-flashes) tripped the alarm. 3. If the system was triggered so many times that NPC is active the remote will emit the above notifications with 2 beeps and 5...
Owner Manual
Page 32
...To cancel one-time bypass perform one -time bypass: 1. If the remote is armed. It prevents annoying repetitive trigger sequences due to arm the alarm after exiting the vehicle: Window roll up: If programmed ON this output will not activate. One-time bypass will defeat the following : Arm then ... This feature (if programmed on arm, they will not activate. To activate one of the following actions: Passive arming: If programmed ON the alarm will chirp once to indicate one-time bypass has been activated. The siren will not arm itself. Linked Auxiliary Outputs: If programmed to activate ...
...To cancel one-time bypass perform one -time bypass: 1. If the remote is armed. It prevents annoying repetitive trigger sequences due to arm the alarm after exiting the vehicle: Window roll up: If programmed ON this output will not activate. One-time bypass will defeat the following : Arm then ... This feature (if programmed on arm, they will not activate. To activate one of the following actions: Passive arming: If programmed ON the alarm will chirp once to indicate one-time bypass has been activated. The siren will not arm itself. Linked Auxiliary Outputs: If programmed to activate ...
Owner Manual
Page 33
... zone must not trigger for 60 minutes, or ignition is triggered by NPC® differently; faulty door pin switches or environmental conditions such as false alarms. After the third trigger, NPC® ignores, or bypasses, that sensor or switch (along with any other sensors or switches sharing the same zone) for...® will start over. This ensures that a sensor that the NPC® programming can cause zones to stop working. if the alarm is turned on . If five chirps are covered by an open door for more information. 28 © 2006 directed electronics If the bypassed sensor tries ...
... zone must not trigger for 60 minutes, or ignition is triggered by NPC® differently; faulty door pin switches or environmental conditions such as false alarms. After the third trigger, NPC® ignores, or bypasses, that sensor or switch (along with any other sensors or switches sharing the same zone) for...® will start over. This ensures that a sensor that the NPC® programming can cause zones to stop working. if the alarm is turned on . If five chirps are covered by an open door for more information. 28 © 2006 directed electronics If the bypassed sensor tries ...
Owner Manual
Page 35
.... 30 © 2006 directed electronics note: The LCD transmitter will display the current sensor sensitivity setting. cator will also have the zone 2 icon and the alarm icon indicating. 4. The in vehicle LED will flash for the duration of shock adjustment mode. The sensor bar indi- shock sensor adjustment ➜ To enter...
.... 30 © 2006 directed electronics note: The LCD transmitter will display the current sensor sensitivity setting. cator will also have the zone 2 icon and the alarm icon indicating. 4. The in vehicle LED will flash for the duration of shock adjustment mode. The sensor bar indi- shock sensor adjustment ➜ To enter...
Owner Manual
Page 42
... sensors or switches you have had installed. Number of LED flashes used for warn away and full alarm notification. © 2006 directed electronics 37 Door switch trigger Optional sensor inputs for warn away and full alarm notification. The standard input assignments are listed below, along with spaces to identify that input. ➜...
... sensors or switches you have had installed. Number of LED flashes used for warn away and full alarm notification. © 2006 directed electronics 37 Door switch trigger Optional sensor inputs for warn away and full alarm notification. The standard input assignments are listed below, along with spaces to identify that input. ➜...
Owner Manual
Page 44
...user. Owner Recognition lets up to program different settings for more information. The programmer makes it possible to four users of the system settings. The alarm will recall the settings assigned to non-volatile memory. Then, whenever a specific transmitter is almost like having four separate... alarms in © 2006 directed electronics 39 It is used with your dealer can program many of the system have different settings that transmitter. Check ...
...user. Owner Recognition lets up to program different settings for more information. The programmer makes it possible to four users of the system settings. The alarm will recall the settings assigned to non-volatile memory. Then, whenever a specific transmitter is almost like having four separate... alarms in © 2006 directed electronics 39 It is used with your dealer can program many of the system have different settings that transmitter. Check ...
Owner Manual
Page 47
... programmed for passive arming and active lock, if the system is disarmed without a door being stolen at all times, regardless of whether or not the alarm is turned off. This feature is also possible to indicate the AED arming cycle. Once the key is bypassed and cannot trigger the system. note...
... programmed for passive arming and active lock, if the system is disarmed without a door being stolen at all times, regardless of whether or not the alarm is turned off. This feature is also possible to indicate the AED arming cycle. Once the key is bypassed and cannot trigger the system. note...
Owner Manual
Page 49
...; button required to disarm the security system, AED, or the VRS® system can be either full volume or six decibels quieter than the full alarm blast. 44 © 2006 directed electronics If an instant trigger is desired, the progressive door trigger can be programmed off : When the system is armed...
...; button required to disarm the security system, AED, or the VRS® system can be either full volume or six decibels quieter than the full alarm blast. 44 © 2006 directed electronics If an instant trigger is desired, the progressive door trigger can be programmed off : When the system is armed...
Owner Manual
Page 54
... in-vehicle LED will close upon locking the vehicle. Multi-level Arming: Allows bypassing of user selected alarm zones of the pair which tripped the alarm. Grouped Arming: Allows bypassing of the group of the optional sensors need to be armed after turning the ignition Off and exiting the ... triggered this system. High Security Disarm: If the system is left open the system will report showing both warn-away and full alarm of each other for full alarm. note: In dual sensor mode, the LCD remote will be triggered within 1second of the vehicle. © 2006 directed electronics ...
... in-vehicle LED will close upon locking the vehicle. Multi-level Arming: Allows bypassing of user selected alarm zones of the pair which tripped the alarm. Grouped Arming: Allows bypassing of the group of the optional sensors need to be armed after turning the ignition Off and exiting the ... triggered this system. High Security Disarm: If the system is left open the system will report showing both warn-away and full alarm of each other for full alarm. note: In dual sensor mode, the LCD remote will be triggered within 1second of the vehicle. © 2006 directed electronics ...
Owner Manual
Page 55
Remote Start Reporting: This channel 3 program option allows bypass of the security inputs that would trigger an alarm when activating an added optional remote start system, but still retains a high level of the many expansion options available. Retained Accessory Power: This output from ...