...your computer 17 Operation Starting the Scanner Applications Automatically 18 • Setting the event 18 Document Specifications 20 • Acceptable documents 20 • Acceptable cards 20 • Unacceptable documents 20 Loading Documents 21 • When scanning ...scanner 26 • Inside of the scanner 26 • Optional Roller Cleaning Paper (KV-SS03 26 • Cleaning the rollers 27 • Cleaning the scanning glass section and reference area 30 Replacing Consumables 31 • Replacing the double-feed prevention roller 31 • Replacing the paper feed roller...
...your computer 17 Operation Starting the Scanner Applications Automatically 18 • Setting the event 18 Document Specifications 20 • Acceptable documents 20 • Acceptable cards 20 • Unacceptable documents 20 Loading Documents 21 • When scanning ...scanner 26 • Inside of the scanner 26 • Optional Roller Cleaning Paper (KV-SS03 26 • Cleaning the rollers 27 • Cleaning the scanning glass section and reference area 30 Replacing Consumables 31 • Replacing the double-feed prevention roller 31 • Replacing the paper feed roller...
Scanner
Page 31
... sheets The scanner counter can be replaced" warning message is displayed on the screen of the User Utility. Note: The usable life of each roller periodically. The Roller Exchange Kit (KV-SS030) contains two double-feed prevention rollers and one paper feed roller. It may be very hot. Please purchase the Roller Exchange Kit (KV-SS030), and replace each roller is...
... sheets The scanner counter can be replaced" warning message is displayed on the screen of the User Utility. Note: The usable life of each roller periodically. The Roller Exchange Kit (KV-SS030) contains two double-feed prevention rollers and one paper feed roller. It may be very hot. Please purchase the Roller Exchange Kit (KV-SS030), and replace each roller is...
Scanner
Page 32
Replacing Consumables 4 Remove the double-feed prevention roller in the direction of the arrow shown in the illustration. 5 Retrieve the new double-feed prevention roller from the optional Roller Exchange Kit (KV-SS030). 6 Install the new double-feed prevention roller into the metal holder with the longer groove facing to the right-side (Rear view). 7 Close the double-feed prevention roller cover (Green) firmly. • Make sure both sides of the double-feed prevention roller cover (Green) lock in place. 32
Replacing Consumables 4 Remove the double-feed prevention roller in the direction of the arrow shown in the illustration. 5 Retrieve the new double-feed prevention roller from the optional Roller Exchange Kit (KV-SS030). 6 Install the new double-feed prevention roller into the metal holder with the longer groove facing to the right-side (Rear view). 7 Close the double-feed prevention roller cover (Green) firmly. • Make sure both sides of the double-feed prevention roller cover (Green) lock in place. 32
Scanner
Page 33
8 Close the ADF door. • Push down on the User Utility window. • Refer to the User Utility Reference Manual. 33 Replacing Consumables 9 Clear the roller replacing counter with the User Utility. • After the double-feed prevention roller has been replaced, press the [Clear Counter] button to clear the [After Replace "Doublefeed Prevention Roller"] counter to zero on both sides of the ADF door gently until it clicks into place.
8 Close the ADF door. • Push down on the User Utility window. • Refer to the User Utility Reference Manual. 33 Replacing Consumables 9 Clear the roller replacing counter with the User Utility. • After the double-feed prevention roller has been replaced, press the [Clear Counter] button to clear the [After Replace "Doublefeed Prevention Roller"] counter to zero on both sides of the ADF door gently until it clicks into place.
Scanner
Page 34
ADF door 4 Remove the paper feed roller. 34 Door open the ADF door. Replacing Consumables Replacing the paper feed roller 1 Turn the power off. • Push the power switch. • Unplug the AC adaptor from the scanner. 2 Press the door open button, and open button 3 Open the paper feed roller cover (Green) in the direction of the arrow shown in the illustration.
ADF door 4 Remove the paper feed roller. 34 Door open the ADF door. Replacing Consumables Replacing the paper feed roller 1 Turn the power off. • Push the power switch. • Unplug the AC adaptor from the scanner. 2 Press the door open button, and open button 3 Open the paper feed roller cover (Green) in the direction of the arrow shown in the illustration.
Scanner
Page 35
Replacing Consumables 7 Close the paper feed roller cover (Green) firmly. • Make sure both sides of the paper feed roller cover (Green) lock in place. • After installing the paper feed roller, confirm that the paper feed roller can rotate in the feeding direction. 8 Close the ADF door. • Push down on the left side. 5 Open the optional Roller Exchange Kit (KV-SS030), and retrieve a new paper feed roller. 6 Install the new paper feed roller with the gear on both sides of the ADF door gently until it clicks into place. 35
Replacing Consumables 7 Close the paper feed roller cover (Green) firmly. • Make sure both sides of the paper feed roller cover (Green) lock in place. • After installing the paper feed roller, confirm that the paper feed roller can rotate in the feeding direction. 8 Close the ADF door. • Push down on the left side. 5 Open the optional Roller Exchange Kit (KV-SS030), and retrieve a new paper feed roller. 6 Install the new paper feed roller with the gear on both sides of the ADF door gently until it clicks into place. 35
Scanner
Page 36
Replacing Consumables 9 Clear the roller replacing counter with the User Utility. • After the paper feed roller has been replaced, press the [Clear Counter] button to clear the [After Replace "Paper Feed Roller"] counter to zero on the User Utility window. • Refer to the User Utility Reference Manual. 36
Replacing Consumables 9 Clear the roller replacing counter with the User Utility. • After the paper feed roller has been replaced, press the [Clear Counter] button to clear the [After Replace "Paper Feed Roller"] counter to zero on the User Utility window. • Refer to the User Utility Reference Manual. 36
Scanner
Page 39
KV-S1025C KV-S1020C Scanning face Duplex scanning Simplex scanning Simplex scanning Scanning method CCD (600 dpi) Background: Black Scanning width 218 mm (8.58 in .)*2 40 - 209 g /m2 (... vary with the kinds of the scanner and the rollers is also available. 0.05 - 0.2 mm (2.0 - 7.9 mils*4) 50 sheets [80 g/m2 (20 lb.) New paper] 50 sheets [80 g/m2 (20 lb.) New paper] 500000 sheets Roller replacement*5 Double-feed prevention roller : 50000 sheets Paper feed roller : 100000 sheets Maintenance Clean the rollers, sensors, and glasses once a week or...
KV-S1025C KV-S1020C Scanning face Duplex scanning Simplex scanning Simplex scanning Scanning method CCD (600 dpi) Background: Black Scanning width 218 mm (8.58 in .)*2 40 - 209 g /m2 (... vary with the kinds of the scanner and the rollers is also available. 0.05 - 0.2 mm (2.0 - 7.9 mils*4) 50 sheets [80 g/m2 (20 lb.) New paper] 50 sheets [80 g/m2 (20 lb.) New paper] 500000 sheets Roller replacement*5 Double-feed prevention roller : 50000 sheets Paper feed roller : 100000 sheets Maintenance Clean the rollers, sensors, and glasses once a week or...
Scanner
Page 42
... glass section is curled or folded. The height of all the documents on the specified paper (See page 20), and scan the copy. The document is dirty. Replace the paper feed roller and the double-feed prevention roller (See pages 31 to the RTIV or PIE reference manual. The...scanning glass section (See page 30). Troubleshooting Symptom Possible Cause Remedy Double feeding or skewing problems occur frequently, or the scanner stops feeding while scanning. Flatten the document, and load it again after flattening the pages. The height of the specified size, and scan the copy (See ...
... glass section is curled or folded. The height of all the documents on the specified paper (See page 20), and scan the copy. The document is dirty. Replace the paper feed roller and the double-feed prevention roller (See pages 31 to the RTIV or PIE reference manual. The...scanning glass section (See page 30). Troubleshooting Symptom Possible Cause Remedy Double feeding or skewing problems occur frequently, or the scanner stops feeding while scanning. Flatten the document, and load it again after flattening the pages. The height of the specified size, and scan the copy (See ...
Scanner
Page 44
...labels 8 CD-ROM 1, 40 Cleaning the unit 26 Clearing paper jams 23 Complete installation 14 Component identification 9 Conveyor roller 29 Custom installation 15 D Document guides 9, 21, 22 Door open button . . . . . 9, 23, 27, 30, 31, 34 Double-feed prevention 31 Double...Documents 21 M Mixed batch card guide 9, 25 Multiple sheets 21 O Option/consumables 40 P Paper feed roller 28, 34, 35 Paper jams 23 Power connector 9 Power cord 9, 12 Power switch 9, 12 Precautions 8 R Reference area 26, 30 Repacking 38 Replacing Consumables 31 Roller cleaning paper 26, 29, 40 Roller...
...labels 8 CD-ROM 1, 40 Cleaning the unit 26 Clearing paper jams 23 Complete installation 14 Component identification 9 Conveyor roller 29 Custom installation 15 D Document guides 9, 21, 22 Door open button . . . . . 9, 23, 27, 30, 31, 34 Double-feed prevention 31 Double...Documents 21 M Mixed batch card guide 9, 25 Multiple sheets 21 O Option/consumables 40 P Paper feed roller 28, 34, 35 Paper jams 23 Power connector 9 Power cord 9, 12 Power switch 9, 12 Precautions 8 R Reference area 26, 30 Repacking 38 Replacing Consumables 31 Roller cleaning paper 26, 29, 40 Roller...