... through 16 3-20 Model Name 3-20 Configuration ID 3-20 Edge to Edge 3-21 EP SETUP 3-21 EP Defaults 3-21 Fuser Temperature (Fuser Temp 3-21 Fuser Page Count 3-21 Warm Up Time 3-21 Transfer 3-21 Print Contrast 3-22 Charge Roll 3-22 Gap Adjust 3-22 Auto Dark Adj 3-...EXIT DIAGNOSTICS (models T650, T652, and T654 3-24 Configuration menu (CONFIG MENU) (models T650, T652, and T654 3-25 Entering Configuration Menu (models T650, T652, and T654 3-25 Available menus 3-25 Maintenance page count (Maint Cnt Value 3-25 Maintenance page counter reset (Reset Cnt 3-26 Print quality pages (Prt ...
... through 16 3-20 Model Name 3-20 Configuration ID 3-20 Edge to Edge 3-21 EP SETUP 3-21 EP Defaults 3-21 Fuser Temperature (Fuser Temp 3-21 Fuser Page Count 3-21 Warm Up Time 3-21 Transfer 3-21 Print Contrast 3-22 Charge Roll 3-22 Gap Adjust 3-22 Auto Dark Adj 3-...EXIT DIAGNOSTICS (models T650, T652, and T654 3-24 Configuration menu (CONFIG MENU) (models T650, T652, and T654 3-25 Entering Configuration Menu (models T650, T652, and T654 3-25 Available menus 3-25 Maintenance page count (Maint Cnt Value 3-25 Maintenance page counter reset (Reset Cnt 3-26 Print quality pages (Prt ...
Service Manual
Page 217
...and press to change, and press . 4. Resetting the Printer displays, the printer performs a POR, and returns to exit the Diagnostics menu. 4062-XXX EP SETUP EP Defaults Fuser Temp Fuser Page Count Warm Up Time Transfer Print Contrast Charge Roll...Display Log Print Log Clear Log EXIT DIAGNOSTICS See "EP Defaults" on page 3-21 See "Fuser Temperature (Fuser Temp)" on page 3-21 See "Fuser Page Count" on page 3-21 See "Warm Up Time" on page 3-21 See "Transfer" on page..."Clear Log" on page 3-24 Exiting Diagnostics mode (models T650, T652, and T654) Select Exit Diagnostics to Ready mode.
...and press to change, and press . 4. Resetting the Printer displays, the printer performs a POR, and returns to exit the Diagnostics menu. 4062-XXX EP SETUP EP Defaults Fuser Temp Fuser Page Count Warm Up Time Transfer Print Contrast Charge Roll...Display Log Print Log Clear Log EXIT DIAGNOSTICS See "EP Defaults" on page 3-21 See "Fuser Temperature (Fuser Temp)" on page 3-21 See "Fuser Page Count" on page 3-21 See "Warm Up Time" on page 3-21 See "Transfer" on page..."Clear Log" on page 3-24 Exiting Diagnostics mode (models T650, T652, and T654) Select Exit Diagnostics to Ready mode.
Service Manual
Page 233
... value for Confirguration ID 2. 4. EP SETUP EP Defaults This setting is used to its factory default value. The default is Medium. Fuser Page Count The fuser page count can be changed , press to increase or to exit without changing the settings. If Invalid ID appears, the entry is discarded, and...used to restore each printer setting listed in some types of the paper for entering the Configuration ID, and press . Select Restore to reset the values to the factory settings, and select Do Not Restore to decrease the value. This time period lets the backup roll heat ...
... value for Confirguration ID 2. 4. EP SETUP EP Defaults This setting is used to its factory default value. The default is Medium. Fuser Page Count The fuser page count can be changed , press to increase or to exit without changing the settings. If Invalid ID appears, the entry is discarded, and...used to restore each printer setting listed in some types of the paper for entering the Configuration ID, and press . Select Restore to reset the values to the factory settings, and select Do Not Restore to decrease the value. This time period lets the backup roll heat ...
Service Manual
Page 257
... characters, including 0 through 9 and A through f. To set at the factory when the printer is manufactured, however, the servicer may need to reset Configuration ID 1 or Configuration ID 2 whenever you have a question, touch the question mark icon. • To exit without changing the numbers, touch... using hardware sensors. If the process is successful, Submitting Selection appears on the screen. EP SETUP EP SETUP EP Defaults Fuser Temp Fuser Page Count Warm Up Time Transfer Print Contrast Normal 127 Medium Medium Submit Back Diagnostic aids 3-45 When the setting is Off, the...
... characters, including 0 through 9 and A through f. To set at the factory when the printer is manufactured, however, the servicer may need to reset Configuration ID 1 or Configuration ID 2 whenever you have a question, touch the question mark icon. • To exit without changing the numbers, touch... using hardware sensors. If the process is successful, Submitting Selection appears on the screen. EP SETUP EP SETUP EP Defaults Fuser Temp Fuser Page Count Warm Up Time Transfer Print Contrast Normal 127 Medium Medium Submit Back Diagnostic aids 3-45 When the setting is Off, the...
Service Manual
Page 258
...Diagnostics Menu. The default setting is Medium. Print Contrast The print contrast setting controls the developer voltage offset. Touch to select Restore to reset the values to the factory settings, and touch Restore to Low, Medium, or High. Touch Back to return to Diagnostics Menu. ... Medium, or High. The default is Medium. 3-46 Service Manual Fuser Page Count The fuser page count can be changed. Touch the up and helps reduce curl in EP SETUP to exit without changing the settings. Fuser Temperature (Fuser Temp) This adjustment can only be viewed and cannot be used to...
...Diagnostics Menu. The default setting is Medium. Print Contrast The print contrast setting controls the developer voltage offset. Touch to select Restore to reset the values to the factory settings, and touch Restore to Low, Medium, or High. Touch Back to return to Diagnostics Menu. ... Medium, or High. The default is Medium. 3-46 Service Manual Fuser Page Count The fuser page count can be changed. Touch the up and helps reduce curl in EP SETUP to exit without changing the settings. Fuser Temperature (Fuser Temp) This adjustment can only be viewed and cannot be used to...
Service Manual
Page 524
... number 40X4723 40X4724 40X4765 40X4766 40X4767 40X4768 Maintenance Interval 300K 300K 300K 150K 150K 150K After replacing the kit, the maintenance count must be reset to zero to replace the fuser assembly, transfer roller, charge roll, and pick tires at required maintenance intervals. 4062-XXX Scheduled maintenance Maintenance kit The operator panel displays...
... number 40X4723 40X4724 40X4765 40X4766 40X4767 40X4768 Maintenance Interval 300K 300K 300K 150K 150K 150K After replacing the kit, the maintenance count must be reset to zero to replace the fuser assembly, transfer roller, charge roll, and pick tires at required maintenance intervals. 4062-XXX Scheduled maintenance Maintenance kit The operator panel displays...
Service Manual
Page 573
...defaults 3-21, 3-46 factory defaults 3-28, 3-54 US/Non-US defaults 3-19, 3-44 4062-XXX diagnostic information confirm the installation status 2-2 Power-on Reset sequence 2-2 diagnostics error code table 2-14 diagnostics menu accessing 3-30 available tests 3-31 BASE SENSOR TEST 3-42 DEVICE TESTS Disk Test/Clean 3-43 Quick ...3-40 Motor Test 3-39 Quick Test 3-38 Sensor Test 3-39 Top Margin 3-38, 3-39 EP SETUP Charge Roll 3-46 EP Defaults 3-46 Fuser Page Count 3-46 Fuser Temp 3-46 Gap Adjust 3-47 Print Contrast 3-46 Transfer 3-46 Warm Up Time 3-46 EVENT LOG Clear Log 3-48 Display Log 3-47 Print...
...defaults 3-21, 3-46 factory defaults 3-28, 3-54 US/Non-US defaults 3-19, 3-44 4062-XXX diagnostic information confirm the installation status 2-2 Power-on Reset sequence 2-2 diagnostics error code table 2-14 diagnostics menu accessing 3-30 available tests 3-31 BASE SENSOR TEST 3-42 DEVICE TESTS Disk Test/Clean 3-43 Quick ...3-40 Motor Test 3-39 Quick Test 3-38 Sensor Test 3-39 Top Margin 3-38, 3-39 EP SETUP Charge Roll 3-46 EP Defaults 3-46 Fuser Page Count 3-46 Fuser Temp 3-46 Gap Adjust 3-47 Print Contrast 3-46 Transfer 3-46 Warm Up Time 3-46 EVENT LOG Clear Log 3-48 Display Log 3-47 Print...