User's Guide (2 MB)
Page 22
...6.38 in .) unless the size is included with a special label cartridge for information on obtaining a label fuser cleaner. T616(n) standard tray T614(n) standard tray T612(n) standard tray T610(n) standard tray 250-sheet drawer 500-sheet drawer ... labels2 Dual web labels2 1 This size setting formats the page for 215.9 x 355.6 mm (8.5 x 14 in . the label fuser cleaner is specified by the software application. 2 Label applications require a special label fuser cleaner which precludes duplexing; Refer to the Administrator's Guide for label applications.
...6.38 in .) unless the size is included with a special label cartridge for information on obtaining a label fuser cleaner. T616(n) standard tray T614(n) standard tray T612(n) standard tray T610(n) standard tray 250-sheet drawer 500-sheet drawer ... labels2 Dual web labels2 1 This size setting formats the page for 215.9 x 355.6 mm (8.5 x 14 in . the label fuser cleaner is specified by the software application. 2 Label applications require a special label fuser cleaner which precludes duplexing; Refer to the Administrator's Guide for label applications.
User's Guide (2 MB)
Page 24
... 1 For 60 to 176 g/m2 paper, grain long fibers are not supported by Optra T616(n). 8 Information on whether your vinyl label converter has passed Lexmark's criteria is available at Lexmark's Web site (www.lexmark.com); Choosing Print Materials 24 Integrated tray5 - grain short is preferred for heavier papers...-free or up to 25% cotton content. 5 The duplex unit supports the same weights and types as the printer, except for transparencies and envelopes. 6 Dedicated label printing requires a special label fuser cleaner which precludes duplex printing. 7 Vinyl labels are recommended;
... 1 For 60 to 176 g/m2 paper, grain long fibers are not supported by Optra T616(n). 8 Information on whether your vinyl label converter has passed Lexmark's criteria is available at Lexmark's Web site (www.lexmark.com); Choosing Print Materials 24 Integrated tray5 - grain short is preferred for heavier papers...-free or up to 25% cotton content. 5 The duplex unit supports the same weights and types as the printer, except for transparencies and envelopes. 6 Dedicated label printing requires a special label fuser cleaner which precludes duplex printing. 7 Vinyl labels are recommended;
Administrator's Guide (1.4 MB)
Page 127
...(n) 220V, 550W Maintenance kit for Optra T616(n) and T614(n) 115V, 875W Maintenance kit for your specific printer. Maintenance kit We recommend you are in your printer. The maintenance kit contains all the items necessary to replace the fuser assembly, the charge roll, and the transfer roll. Ordering supplies For best results, use Lexmark supplies with the...
...(n) 220V, 550W Maintenance kit for Optra T616(n) and T614(n) 115V, 875W Maintenance kit for your specific printer. Maintenance kit We recommend you are in your printer. The maintenance kit contains all the items necessary to replace the fuser assembly, the charge roll, and the transfer roll. Ordering supplies For best results, use Lexmark supplies with the...
Administrator's Guide (1.4 MB)
Page 129
Description Volts/Watts Part number Fuser assembly for Optra T612(n) and T610(n) 99A1660 115V, 550W Fuser assembly for Optra T612(n) and T610(n) 99A1661 220V, 550W Fuser assembly for Optra T616(n) and T614(n) 99A1584 115V, 875W Fuser assembly for your specific printer. Transfer roll To order a transfer roll kit, use Lexmark part number 99A1017. Fuser assembly See the following table for the fuser assembly part number for Optra T616(n) and T614(n) 99A1585 220V, 875W Maintaining Your Printer 129 Charge roll To order a charge roll kit, use Lexmark part number 99A1015.
Description Volts/Watts Part number Fuser assembly for Optra T612(n) and T610(n) 99A1660 115V, 550W Fuser assembly for Optra T612(n) and T610(n) 99A1661 220V, 550W Fuser assembly for Optra T616(n) and T614(n) 99A1584 115V, 875W Fuser assembly for your specific printer. Transfer roll To order a transfer roll kit, use Lexmark part number 99A1017. Fuser assembly See the following table for the fuser assembly part number for Optra T616(n) and T614(n) 99A1585 220V, 875W Maintaining Your Printer 129 Charge roll To order a charge roll kit, use Lexmark part number 99A1015.
Technical Reference
Page 298
7-3 Specifications Power Requirements The following table lists the nominal average power requirements (including fuser power). Table 7-3: Power Requirements Printer Model Optra Color 45 Optra Color 1200 Optra E310, E312 Optra C710 Optra M410, M412 State 120 V 230 V 120 V 230 V 120 V 230 V 120 V ... 32W 19W 19W 19W 19W 24W 24W Rated Short Term 0.5A 0.3A 7.5A 4.0A N/A N/A 8.4A 4.0A 5.1A 2.6A Current Printer Model Optra T610 1 Optra T612 1 Optra T614 1 Optra T616 1 Optra W810 State Average Continuous Printing 110 V 220 V 110 V 220 V 110 V 332W 2 332W 2 409W 2 409W 2 457W 2...
7-3 Specifications Power Requirements The following table lists the nominal average power requirements (including fuser power). Table 7-3: Power Requirements Printer Model Optra Color 45 Optra Color 1200 Optra E310, E312 Optra C710 Optra M410, M412 State 120 V 230 V 120 V 230 V 120 V 230 V 120 V ... 32W 19W 19W 19W 19W 24W 24W Rated Short Term 0.5A 0.3A 7.5A 4.0A N/A N/A 8.4A 4.0A 5.1A 2.6A Current Printer Model Optra T610 1 Optra T612 1 Optra T614 1 Optra T616 1 Optra W810 State Average Continuous Printing 110 V 220 V 110 V 220 V 110 V 332W 2 332W 2 409W 2 409W 2 457W 2...
Technical Reference
Page 383
...Close Duplex Door Insert Duplex Option Load Staples Printer Model Message Intervention Required Priming Failed. Retry? Retry? Intervention Required OPMSG Intervention Required STMSG Intervention Required Replace Fuser Intervention Required Replace Transfer Kit Intervention Required Incompatible... 40096 3-67 40096 3-67 40101 Return String Priming Failed. B-20 PJL Support Optra Color 45 Optra Color 1200 Optra E310, E312 Optra C710 Optra M410, M412 Optra T610 Optra T612 Optra T614 Optra T616 Optra W810 Table B-11: PJL Messages for Attendance Conditions (Continued) Supported ✘...
...Close Duplex Door Insert Duplex Option Load Staples Printer Model Message Intervention Required Priming Failed. Retry? Retry? Intervention Required OPMSG Intervention Required STMSG Intervention Required Replace Fuser Intervention Required Replace Transfer Kit Intervention Required Incompatible... 40096 3-67 40096 3-67 40101 Return String Priming Failed. B-20 PJL Support Optra Color 45 Optra Color 1200 Optra E310, E312 Optra C710 Optra M410, M412 Optra T610 Optra T612 Optra T614 Optra T616 Optra W810 Table B-11: PJL Messages for Attendance Conditions (Continued) Supported ✘...