Service Guide
Page 5
... guidance For system firmware updates and onboard device drivers and software to manage your system components and their supported accessories, refer to the following resources available at http://www.intel.com/support. Preface Preface About this Manual This...Additional Information and Software For additional information about this Document or Software Intel® Server System R1000RP Product Family Technical Product Specification Intel® Server Board S1200V3RP Technical Product Specification Intel® Server System R1000RP Product Family Quick Installation Guide Spares and...
... guidance For system firmware updates and onboard device drivers and software to manage your system components and their supported accessories, refer to the following resources available at http://www.intel.com/support. Preface Preface About this Manual This...Additional Information and Software For additional information about this Document or Software Intel® Server System R1000RP Product Family Technical Product Specification Intel® Server Board S1200V3RP Technical Product Specification Intel® Server System R1000RP Product Family Quick Installation Guide Spares and...
Service Guide
Page 13
... of the server system features, and diagrams showing the location of the Intel® Server System R1000RP family. Intel® Server System R1000RP Family Basic Configuration Server Product Code R1304RPSSFBN R1304RPOSHBN R1208RPOSHOR R1208RPMSHOR R1304RPMSHOR Board S1200V3RPS S1200V3RPO S1200V3RPO S1200V3RPM S1200V3RPM Hard driver 4x3.5", Fixed 4x3.5", Hotswap 8x2.5", Hotswap 8x2.5", Hotswap 4x3.5", Hotswap Power supply...
... of the server system features, and diagrams showing the location of the Intel® Server System R1000RP family. Intel® Server System R1000RP Family Basic Configuration Server Product Code R1304RPSSFBN R1304RPOSHBN R1208RPOSHOR R1208RPMSHOR R1304RPMSHOR Board S1200V3RPS S1200V3RPO S1200V3RPO S1200V3RPM S1200V3RPM Hard driver 4x3.5", Fixed 4x3.5", Hotswap 8x2.5", Hotswap 8x2.5", Hotswap 4x3.5", Hotswap Power supply...
Service Guide
Page 6
..., "Document and Guides". Intel® Server Board S1200V3RP Quick Start User Guide Intel® Server System P4000RP Family Quick Installation User Guide Spares and Configuration Guide Intel® Server Configurator tool http://serverconfigurator.intel.com/sct_app.aspx#/SctMain Power Budget Tool Intel® Server Management Software For firmware and drivers. If you just received this...
..., "Document and Guides". Intel® Server Board S1200V3RP Quick Start User Guide Intel® Server System P4000RP Family Quick Installation User Guide Spares and Configuration Guide Intel® Server Configurator tool http://serverconfigurator.intel.com/sct_app.aspx#/SctMain Power Budget Tool Intel® Server Management Software For firmware and drivers. If you just received this...
Technical Product Specification
Page 35
... series chipset implements an SPI Interface as RAID 0 and RAID 1 on a single set of the Intel® C220 series chipset. Revision 1.0 23 Intel® Server Board S1200V3RP Functional Architecture requires appropriate software support (for example, an AHCI driver) and for the BIOS flash device. Other RAID features include hot-spare support, SMART alerting, and...
... series chipset implements an SPI Interface as RAID 0 and RAID 1 on a single set of the Intel® C220 series chipset. Revision 1.0 23 Intel® Server Board S1200V3RP Functional Architecture requires appropriate software support (for example, an AHCI driver) and for the BIOS flash device. Other RAID features include hot-spare support, SMART alerting, and...
Technical Product Specification
Page 42
...16 direct, 32 shared) Serial general-purpose I/O Ports (80 in graphic driver for accelerating video processing - Functional Architecture Intel® Server Board S1200V3RP Next Generation Intel® Clear Video Technology HD Support is 3840x2160@60Hz, 24bpp. Full AVC/VC1/MPEG2...Both BMC and Internal graphic need to 3-Display Architecture and Configuration Overview (Supporting: 3rd Generation Intel® Core™ Processors and4th Generation Intel® Core™ Processors). 3.5.3 Baseboard Management Controller The server board utilizes the following features...
...16 direct, 32 shared) Serial general-purpose I/O Ports (80 in graphic driver for accelerating video processing - Functional Architecture Intel® Server Board S1200V3RP Next Generation Intel® Clear Video Technology HD Support is 3840x2160@60Hz, 24bpp. Full AVC/VC1/MPEG2...Both BMC and Internal graphic need to 3-Display Architecture and Configuration Overview (Supporting: 3rd Generation Intel® Core™ Processors and4th Generation Intel® Core™ Processors). 3.5.3 Baseboard Management Controller The server board utilizes the following features...
Technical Product Specification
Page 84
...floppy disks over media redirection. If either a local CD drive or else an ISO image file; Advanced Management Feature Support (RMM4) Intel® Server Board S1200V3RP Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software ...but not across an AC power loss or BMC reset. 7.2.2 Network Port Usage The KVM and media redirection features use of device drivers during install. USB storage devices appear as bootable devices. the Floppy/USB device may also require the use the following capabilities are ...
...floppy disks over media redirection. If either a local CD drive or else an ISO image file; Advanced Management Feature Support (RMM4) Intel® Server Board S1200V3RP Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software ...but not across an AC power loss or BMC reset. 7.2.2 Network Port Usage The KVM and media redirection features use of device drivers during install. USB storage devices appear as bootable devices. the Floppy/USB device may also require the use the following capabilities are ...
Technical Product Specification
Page 130
... a RAID Volume has not previously been created that is compatible with Intel® RAID C220 Upgrade Keys. RAID levels supported and required drivers depend on the onboard SATA ports. Intel(R) RSTe: Provides pass-through drive support. BIOS Setup Interface Intel® Server Board S1200V3RP If the SATA Controller is enabled, and RAID Mode has been...
... a RAID Volume has not previously been created that is compatible with Intel® RAID C220 Upgrade Keys. RAID levels supported and required drivers depend on the onboard SATA ports. Intel(R) RSTe: Provides pass-through drive support. BIOS Setup Interface Intel® Server Board S1200V3RP If the SATA Controller is enabled, and RAID Mode has been...
Technical Product Specification
Page 131
... Configuration Screen] - [Screen Map] 4. Intel® Server Board S1200V3RP BIOS Setup Interface Intel(R) Integrated RAID Module Intel(R) Integrated RAID Module RMS25PB040 Intel(R) Integrated RAID Module RMT3PB080 Intel(R) Integrated RAID Module RMS25CB080 Intel(R) Integrated RAID Module RMS25CB040 Intel(R) Integrated RAID Module RMT3CB080 Intel(R) Integrated RAID Module RMS25JB080 Intel(R) Integrated RAID Module RMS25JB040 Intel(R) Integrated RAID Module RMS25KB080 Intel(R) Integrated RAID Module RMS25KB040 Help...
... Configuration Screen] - [Screen Map] 4. Intel® Server Board S1200V3RP BIOS Setup Interface Intel(R) Integrated RAID Module Intel(R) Integrated RAID Module RMS25PB040 Intel(R) Integrated RAID Module RMT3PB080 Intel(R) Integrated RAID Module RMS25CB080 Intel(R) Integrated RAID Module RMS25CB040 Intel(R) Integrated RAID Module RMT3CB080 Intel(R) Integrated RAID Module RMS25JB080 Intel(R) Integrated RAID Module RMS25JB040 Intel(R) Integrated RAID Module RMS25KB080 Intel(R) Integrated RAID Module RMS25KB040 Help...
Technical Product Specification
Page 148
...Screen Map] 4. Disable option will only keep USB Keyboard devices available for either POST or the OS. BIOS Setup Interface Intel® Server Board S1200V3RP Comments: Information only. Note: There is one USB keyboard and one USB mice detected from the BMC KVM function under... by the OS. [Disabled] - Legacy USB Support Option Values: Enabled Disabled Auto Help Text: Enables Legacy USB support. XHCI Pre-Boot Driver Option Values: Enabled Disabled 136 Revision 1.0 Back to [USB Configuration Screen] - [Screen Map] 3. Comments: When the USB controllers are ...
...Screen Map] 4. Disable option will only keep USB Keyboard devices available for either POST or the OS. BIOS Setup Interface Intel® Server Board S1200V3RP Comments: Information only. Note: There is one USB keyboard and one USB mice detected from the BMC KVM function under... by the OS. [Disabled] - Legacy USB Support Option Values: Enabled Disabled Auto Help Text: Enables Legacy USB support. XHCI Pre-Boot Driver Option Values: Enabled Disabled 136 Revision 1.0 Back to [USB Configuration Screen] - [Screen Map] 3. Comments: When the USB controllers are ...
Technical Product Specification
Page 149
... change should be claimed by XHCI driver Comments: and inactive. If the USB controller setting is Disabled, this field is grayed out Back to [USB Configuration Screen] - [Screen Map] 6. Revision 1.0 137 Intel® Server Board S1200V3RP BIOS Setup Interface Help Text: Enable.../Disable XHCI Pre-Boot Driver support Comments: and inactive. If the USB controller setting is Disabled, this field is grayed ...
... change should be claimed by XHCI driver Comments: and inactive. If the USB controller setting is Disabled, this field is grayed out Back to [USB Configuration Screen] - [Screen Map] 6. Revision 1.0 137 Intel® Server Board S1200V3RP BIOS Setup Interface Help Text: Enable.../Disable XHCI Pre-Boot Driver support Comments: and inactive. If the USB controller setting is Disabled, this field is grayed ...
Technical Product Specification
Page 167
... only. Comments: This option controls whether the system goes into "Deep Sleep" or more conventional S5 "Soft-Off" when powered off . Select this driver. EuP LOT6 Off-Mode Option Values: Enabled Disabled Help Text: Enable/disable Ecodesign EuP LOT6 "Deep Sleep" Off-Mode for it. Back to [Server... your OS does not support Plug & Play for the BMC, you will be able to [Server Management Screen] - [Screen Map] 15. Intel® Server Board S1200V3RP BIOS Setup Interface If enabled, the BMC will not appear on LAN action (which cannot be done from a Deep Sleep state).
... only. Comments: This option controls whether the system goes into "Deep Sleep" or more conventional S5 "Soft-Off" when powered off . Select this driver. EuP LOT6 Off-Mode Option Values: Enabled Disabled Help Text: Enable/disable Ecodesign EuP LOT6 "Deep Sleep" Off-Mode for it. Back to [Server... your OS does not support Plug & Play for the BMC, you will be able to [Server Management Screen] - [Screen Map] 15. Intel® Server Board S1200V3RP BIOS Setup Interface If enabled, the BMC will not appear on LAN action (which cannot be done from a Deep Sleep state).
Technical Product Specification
Page 247
Intel® Server Board S1200V3RP Appendix C: POST Code Diagnostic LED Decoder Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB LSB 8h...Init Description 72h 0 1 1 1 0 0 1 0 DXE SB devices Init 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 90h 1 0 0 1 0 0 0 0 DXE BDS Started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers 92h 1 0 0 1 0 0 1 0 DXE PCI Bus begin 93h 1 0 0 1 0 0 1 1 DXE PCI Bus HPC Init 94h 1 0 0 1 0 1 0 0 DXE PCI Bus enumeration 95h 1 0 0 1 0 1 0 1 DXE PCI Bus resource requested 96h 1 0 0 1 0 1 1 0...
Intel® Server Board S1200V3RP Appendix C: POST Code Diagnostic LED Decoder Diagnostic LED Decoder 1 = LED On, 0 = LED Off Checkpoint Upper Nibble Lower Nibble MSB LSB 8h...Init Description 72h 0 1 1 1 0 0 1 0 DXE SB devices Init 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 90h 1 0 0 1 0 0 0 0 DXE BDS Started 91h 1 0 0 1 0 0 0 1 DXE BDS connect drivers 92h 1 0 0 1 0 0 1 0 DXE PCI Bus begin 93h 1 0 0 1 0 0 1 1 DXE PCI Bus HPC Init 94h 1 0 0 1 0 1 0 0 DXE PCI Bus enumeration 95h 1 0 0 1 0 1 0 1 DXE PCI Bus resource requested 96h 1 0 0 1 0 1 1 0...
Technical Product Specification
Page 256
Appendix D: POST Code Errors Intel® Server Board S1200V3RP Error Code 85EB 85EC 85ED 85EE 85EF 8604 8605... sounded whenever a USB device is discovered in POST, or inserted or removed during runtime System halted because Intel® Trusted Execution Technology detected a potential violation of non-critical NVRAM variables BIOS Settings are not sounded... error PCI Express* component encountered a PERR error PCI Express* component encountered an SERR error DXE Boot Service driver: Not enough memory available to inform users on each time the problem is followed by a sequence of failure...
Appendix D: POST Code Errors Intel® Server Board S1200V3RP Error Code 85EB 85EC 85ED 85EE 85EF 8604 8605... sounded whenever a USB device is discovered in POST, or inserted or removed during runtime System halted because Intel® Trusted Execution Technology detected a potential violation of non-critical NVRAM variables BIOS Settings are not sounded... error PCI Express* component encountered a PERR error PCI Express* component encountered an SERR error DXE Boot Service driver: Not enough memory available to inform users on each time the problem is followed by a sequence of failure...
Technical Product Specification
Page 67
...or can download the latest system documentation, drivers, and system software from the Intel® website referenced at the bottom of this page. This system supports the Intel® Xeon® processor E3-1200 V3 series. You cannot use Intel® Xeon® processors not referenced ...the system is loaded on the supported processor list in the Intel® Server Board S1200V3RP Tested Memory List which provides a list of this page. System fans are not hot-swappable. Only supported memory validated by Intel should be used in this server system. You ...
...or can download the latest system documentation, drivers, and system software from the Intel® website referenced at the bottom of this page. This system supports the Intel® Xeon® processor E3-1200 V3 series. You cannot use Intel® Xeon® processors not referenced ...the system is loaded on the supported processor list in the Intel® Server Board S1200V3RP Tested Memory List which provides a list of this page. System fans are not hot-swappable. Only supported memory validated by Intel should be used in this server system. You ...