User Guide
Page 5
... tape drive 60 Installing a SAS/SATA 4 Pac HDD option 63 Installing a second microprocessor 76 Thermal grease 80 Installing a memory module 81 © Copyright IBM Corp. 2010 iii Contents Safety vii Chapter 1. The System x3650 M2 Type 7947 server 1 The IBM Documentation CD 3 Hardware and software requirements 3 Using the Documentation Browser 3 Related documentation 4 Notices and statements in this...
... tape drive 60 Installing a SAS/SATA 4 Pac HDD option 63 Installing a second microprocessor 76 Thermal grease 80 Installing a memory module 81 © Copyright IBM Corp. 2010 iii Contents Safety vii Chapter 1. The System x3650 M2 Type 7947 server 1 The IBM Documentation CD 3 Hardware and software requirements 3 Using the Documentation Browser 3 Related documentation 4 Notices and statements in this...
User Guide
Page 6
...ServeRAID SAS controller from the World Wide Web 131 Software service and support 132 Hardware service and support 132 IBM Taiwan product service 132 iv System x3650 M2 Type 7947: Installation and User's Guide Configuring the server 111 Using the Setup utility 112 Starting the Setup utility 112... on the remote battery tray . . . 96 Moving the SAS controller retention bracket 101 Installing a USB hypervisor memory key 103 Removing a USB hypervisor memory key 104 Installing an Ethernet adapter 105 Installing an optional CD-RW/DVD drive 105 Completing the installation 106 Replacing...
...ServeRAID SAS controller from the World Wide Web 131 Software service and support 132 Hardware service and support 132 IBM Taiwan product service 132 iv System x3650 M2 Type 7947: Installation and User's Guide Configuring the server 111 Using the Setup utility 112 Starting the Setup utility 112... on the remote battery tray . . . 96 Moving the SAS controller retention bracket 101 Installing a USB hypervisor memory key 103 Removing a USB hypervisor memory key 104 Installing an Ethernet adapter 105 Installing an optional CD-RW/DVD drive 105 Completing the installation 106 Replacing...
User Guide
Page 17
...information about the terms of 1.75 inches each. For more information, see http://www.ibm.com/ibm/ clientreference/. The IBM System x3650 M2 Type 7947 server is a 2-U1-high server that are measured in vertical increments of the ...warranty and getting service and assistance, see the Problem Determination and Service Guide that require superior microprocessor performance, efficient memory management, and flexibility. For information about the IBM...
...information about the terms of 1.75 inches each. For more information, see http://www.ibm.com/ibm/ clientreference/. The IBM System x3650 M2 Type 7947 server is a 2-U1-high server that are measured in vertical increments of the ...warranty and getting service and assistance, see the Problem Determination and Service Guide that require superior microprocessor performance, efficient memory management, and flexibility. For information about the IBM...
User Guide
Page 23
...(TOE) support v Four Ethernet ports (two on rear of the microprocessors. For information about the limits for particulates and gases, see http://www.ibm.com/servers/eserver/ serverproven/compat/us/. One PCI Express x16 slot (x16 lanes) Size (2U): v Height: 85.2 mm (3.346 in.) ...: 2302 Btu per microprocessor v Maximum: 128 GB (when 8 GB DIMMs are installed in hot-swap models only. 2. The System x3650 M2 Type 7947 server 7 Two 133 MHz/64-bit PCI-X 1.0a slots - Memory: v Sixteen DIMM connectors (eight per microprocessor) v Minimum: 1 GB DIMM per hour (675 watts) Chapter 1. v One ...
...(TOE) support v Four Ethernet ports (two on rear of the microprocessors. For information about the limits for particulates and gases, see http://www.ibm.com/servers/eserver/ serverproven/compat/us/. One PCI Express x16 slot (x16 lanes) Size (2U): v Height: 85.2 mm (3.346 in.) ...: 2302 Btu per microprocessor v Maximum: 128 GB (when 8 GB DIMMs are installed in hot-swap models only. 2. The System x3650 M2 Type 7947 server 7 Two 133 MHz/64-bit PCI-X 1.0a slots - Memory: v Sixteen DIMM connectors (eight per microprocessor) v Minimum: 1 GB DIMM per hour (675 watts) Chapter 1. v One ...
User Guide
Page 25
..., you can view the information locally through the systems-management interface and view them, using IBM Systems Director. Light path diagnostics status - The System x3650 M2 Type 7947 server 9 You can also copy the log to centrally manage System x and xSeries servers. - v Active Energy ...Determination and Service Guide on the integrated USB memory. Network interfaces and settings - This enables you can use by the server - It collects and analyzes system information to assist in correlation to IBM service and support. Service processor status and ...
..., you can view the information locally through the systems-management interface and view them, using IBM Systems Director. Light path diagnostics status - The System x3650 M2 Type 7947 server 9 You can also copy the log to centrally manage System x and xSeries servers. - v Active Energy ...Determination and Service Guide on the integrated USB memory. Network interfaces and settings - This enables you can use by the server - It collects and analyzes system information to assist in correlation to IBM service and support. Service processor status and ...
User Guide
Page 26
...hard disk drives without user intervention. 10 System x3650 M2 Type 7947: Installation and User's Guide If the applicable device drivers are installed, this switching occurs without data loss and without turning off the server. Memory mirroring stores data in the Problem Determination and...(third-generation double-data-rate), registered, synchronous dynamic random access memory (SDRAM) dual inline memory modules (DIMMs). With the hot-swap feature, you diagnose problems. For more information, see http://www.ibm.com/servers/eserver/xseries/xarchitecture/ enterprise/index.html. - For ...
...hard disk drives without user intervention. 10 System x3650 M2 Type 7947: Installation and User's Guide If the applicable device drivers are installed, this switching occurs without data loss and without turning off the server. Memory mirroring stores data in the Problem Determination and...(third-generation double-data-rate), registered, synchronous dynamic random access memory (SDRAM) dual inline memory modules (DIMMs). With the hot-swap feature, you diagnose problems. For more information, see http://www.ibm.com/servers/eserver/xseries/xarchitecture/ enterprise/index.html. - For ...
User Guide
Page 27
...fails. Note: As of the date of the optional IBM Virtual Media Key provides remote presence and blue-screen capture capability. The System x3650 M2 Type 7947 server 11 The addition of this document, the Linux operating system does not support TOE. The server supports up to ...voltage, and power-supply redundancy v Cable-presence detection on most connectors v Chipkill memory protection v Dual redundant UEFI server firmware images v Error codes and messages v Error correcting code (ECC) L2 cache and system memory v Hot-swap cooling fans with one of the power supplies, the other power...
...fails. Note: As of the date of the optional IBM Virtual Media Key provides remote presence and blue-screen capture capability. The System x3650 M2 Type 7947 server 11 The addition of this document, the Linux operating system does not support TOE. The server supports up to ...voltage, and power-supply redundancy v Cable-presence detection on most connectors v Chipkill memory protection v Dual redundant UEFI server firmware images v Error codes and messages v Error correcting code (ECC) L2 cache and system memory v Hot-swap cooling fans with one of the power supplies, the other power...
User Guide
Page 28
... Power-on self-test (POST) v Predictive Failure Analysis (PFA) alerts on memory, SAS/SATA hard disk drives, fans, and power supplies v Redundant Ethernet capabilities with IBM Systems Director provides many of the core capabilities that are included with failover support v ... of problems that occur on systems and the ability to multiple systems 12 System x3650 M2 Type 7947: Installation and User's Guide These common tasks include discovery, inventory, configuration, system health, monitoring, updates, event notification, and automation for systems and setting critical thresholds that ...
... Power-on self-test (POST) v Predictive Failure Analysis (PFA) alerts on memory, SAS/SATA hard disk drives, fans, and power supplies v Redundant Ethernet capabilities with IBM Systems Director provides many of the core capabilities that are included with failover support v ... of problems that occur on systems and the ability to multiple systems 12 System x3650 M2 Type 7947: Installation and User's Guide These common tasks include discovery, inventory, configuration, system health, monitoring, updates, event notification, and automation for systems and setting critical thresholds that ...
User Guide
Page 37
...continue to turn off the server, if your operating system supports the Wake on LAN feature, the Wake on LAN feature can press and hold the power-control button for system resources depends on the server. The System x3650 M2 Type 7947 server 21 To remove all power cords are disconnected... from the IMM, such as an automatic response to start an orderly shutdown of memory that all power from the server, you...
...continue to turn off the server, if your operating system supports the Wake on LAN feature, the Wake on LAN feature can press and hold the power-control button for system resources depends on the server. The System x3650 M2 Type 7947 server 21 To remove all power cords are disconnected... from the IMM, such as an automatic response to start an orderly shutdown of memory that all power from the server, you...
User Guide
Page 92
...the server. v The server supports up to http://www.ibm.com/systems/support/. 2. Go to two microprocessors. v The microprocessor speeds are 64-bit dual-core or quad-core microprocessors with an integrated memory controller, quick-path interconnect, and shared last cache. therefore... sink. To download the most current level of supported microprocessors. v If you have to install the second microprocessor. 76 System x3650 M2 Type 7947: Installation and User's Guide Installing a second microprocessor The following steps: 1. v Both microprocessors must update the server firmware...
...the server. v The server supports up to http://www.ibm.com/systems/support/. 2. Go to two microprocessors. v The microprocessor speeds are 64-bit dual-core or quad-core microprocessors with an integrated memory controller, quick-path interconnect, and shared last cache. therefore... sink. To download the most current level of supported microprocessors. v If you have to install the second microprocessor. 76 System x3650 M2 Type 7947: Installation and User's Guide Installing a second microprocessor The following steps: 1. v Both microprocessors must update the server firmware...
User Guide
Page 98
...DIMMs is determined by the slowest DIMM in a server run at 1333 MHz - The amount of memory that are available for various system resources and is the reference design file for system resources depends on the DIMM, in the following rules apply to single-rank and dual-rank DDR3 DIMM.... The server supports a minimum of 1 GB and a maximum of 128 GB of the server is not supported. v The maximum operating speed of system memory. All channels in the server. 82 System x3650 M2 Type 7947: Installation and User's Guide When you must be installed for each microprocessor.
...DIMMs is determined by the slowest DIMM in a server run at 1333 MHz - The amount of memory that are available for various system resources and is the reference design file for system resources depends on the DIMM, in the following rules apply to single-rank and dual-rank DDR3 DIMM.... The server supports a minimum of 1 GB and a maximum of 128 GB of the server is not supported. v The maximum operating speed of system memory. All channels in the server. 82 System x3650 M2 Type 7947: Installation and User's Guide When you must be installed for each microprocessor.
User Guide
Page 100
...associated with microprocessor 1 (CPU1). Figure 2. Table 11. Connectors on each memory channel Memory channel Channel 0 Channel 1 DIMM connectors 1, 2, 3, 9, 10, 11 4, 5, 6, 12, 13, 14 Channel 2 7, 8, 15, 16 The following table lists the DIMM connectors on each microprocessor 84 System x3650 M2 Type 7947: Installation and User's Guide Figure 1. For example, the first DIMM pair... have to wait until all of the DIMM pairs. Note: You can install DIMMs for microprocessor 1 are associated with each memory channel. Memory connectors associated with microprocessor 1 socket (CPU1).
...associated with microprocessor 1 (CPU1). Figure 2. Table 11. Connectors on each memory channel Memory channel Channel 0 Channel 1 DIMM connectors 1, 2, 3, 9, 10, 11 4, 5, 6, 12, 13, 14 Channel 2 7, 8, 15, 16 The following table lists the DIMM connectors on each microprocessor 84 System x3650 M2 Type 7947: Installation and User's Guide Figure 1. For example, the first DIMM pair... have to wait until all of the DIMM pairs. Note: You can install DIMMs for microprocessor 1 are associated with each memory channel. Memory connectors associated with microprocessor 1 socket (CPU1).
User Guide
Page 120
... install or remove, do so now. Pull the hypervisor memory key from the connector. 6. Removing a USB hypervisor memory key To remove the USB hypervisor memory key, complete the following steps: 1. If you have other devices to look for information about disabling hypervisor support. 104 System x3650 M2 Type 7947: Installation and User's Guide Turn off the server...
... install or remove, do so now. Pull the hypervisor memory key from the connector. 6. Removing a USB hypervisor memory key To remove the USB hypervisor memory key, complete the following steps: 1. If you have other devices to look for information about disabling hypervisor support. 104 System x3650 M2 Type 7947: Installation and User's Guide Turn off the server...
User Guide
Page 138
... input power. v PECI 2 support. v Serial over LAN Establish a Serial over LAN (SOL). You can access the SOL connection. 122 System x3650 M2 Type 7947: Installation and User's Guide Any standard Telnet client application can remotely view and change the UEFI settings, restart the server, identify the server, and...video, remote keyboard/mouse, and remote storage). ASR is enabled. v Serial over LAN (SOL) connection to watch for an operating-system memory dump. v Power/reset control (power-on the information panel for the OS watchdog timer and restart the server after a timeout, if...
... input power. v PECI 2 support. v Serial over LAN Establish a Serial over LAN (SOL). You can access the SOL connection. 122 System x3650 M2 Type 7947: Installation and User's Guide Any standard Telnet client application can remotely view and change the UEFI settings, restart the server, identify the server, and...video, remote keyboard/mouse, and remote storage). ASR is enabled. v Serial over LAN (SOL) connection to watch for an operating-system memory dump. v Power/reset control (power-on the information panel for the OS watchdog timer and restart the server after a timeout, if...
User Guide
Page 140
.... The remote presence feature provides the following functions: v Remotely viewing video with graphics resolutions up to the IMM memory and mapping it down. 124 System x3650 M2 Type 7947: Installation and User's Guide Note: Approximately 3 minutes after the server is connected to ac power, the power-... On the next screen, select Integrated Management Module. 5. Install the virtual media key into the dedicated slot on the system board (see "Installing an IBM Virtual Media Key" on the server. To locate the IP address, complete the following steps: 1. After the virtual...
.... The remote presence feature provides the following functions: v Remotely viewing video with graphics resolutions up to the IMM memory and mapping it down. 124 System x3650 M2 Type 7947: Installation and User's Guide Note: Approximately 3 minutes after the server is connected to ac power, the power-... On the next screen, select Integrated Management Module. 5. Install the virtual media key into the dedicated slot on the system board (see "Installing an IBM Virtual Media Key" on the server. To locate the IP address, complete the following steps: 1. After the virtual...
User Guide
Page 150
...in the United States, other factors also affect application performance. Adobe and PostScript are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, other countries, or both. Cell Broadband Engine is a trademark of Intel Corporation or its...Important notes Processor speed indicates the internal clock speed of the standard memory with an optional memory module. These products are offered and warranted solely by the third party, not IBM. 134 System x3650 M2 Type 7947: Installation and User's Guide When referring to processor storage, real ...
...in the United States, other factors also affect application performance. Adobe and PostScript are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, other countries, or both. Cell Broadband Engine is a trademark of Intel Corporation or its...Important notes Processor speed indicates the internal clock speed of the standard memory with an optional memory module. These products are offered and warranted solely by the third party, not IBM. 134 System x3650 M2 Type 7947: Installation and User's Guide When referring to processor storage, real ...
User Guide
Page 160
...supply 87 humidity 7 hypervisor memory key installing 103 removing 104 using 123 I IBM Advanced Settings Utility program, overview 128 IBM Director See IBM Systems Director IBM Support Line 132 IBM Systems Director overview 12 server feature 9 updating 128 IBM Virtual Media Key, installing 55 IBM X-Architecture technology 10 IMM ...simple-swap drive 59 simple-swap hard disk drive 58 tape drive 60 USB hypervisor memory key 103 integrated management module, about 8 internal cable routing 39 IP address, obtaining for Web interface 124 144 System x3650 M2 Type 7947: Installation and User's Guide
...supply 87 humidity 7 hypervisor memory key installing 103 removing 104 using 123 I IBM Advanced Settings Utility program, overview 128 IBM Director See IBM Systems Director IBM Support Line 132 IBM Systems Director overview 12 server feature 9 updating 128 IBM Virtual Media Key, installing 55 IBM X-Architecture technology 10 IMM ...simple-swap drive 59 simple-swap hard disk drive 58 tape drive 60 USB hypervisor memory key 103 integrated management module, about 8 internal cable routing 39 IP address, obtaining for Web interface 124 144 System x3650 M2 Type 7947: Installation and User's Guide
User Guide
Page 162
... 58, 60 PCI adapter 54 RAID controller 93 SAS controller 93 SAS riser-card and controller assembly 91 USB hypervisor memory key 104 replacing simple-swap hard disk drive 58 replacing cover 107 reset button 16 retention bracket (tape-enabled SAS ...system pulse LEDs 32 system reliability guidelines 37 system-error LED front 15 rear 18 system-locator LED 15, 18 Systems Director, updating 128 systems management 8, 11, 12 T tape drive, installing 60 telephone numbers 132 temperature 7 thermal grease 80 trademarks 133 turning off the server 21 turning on the server 20 146 System x3650 M2 Type 7947...
... 58, 60 PCI adapter 54 RAID controller 93 SAS controller 93 SAS riser-card and controller assembly 91 USB hypervisor memory key 104 replacing simple-swap hard disk drive 58 replacing cover 107 reset button 16 retention bracket (tape-enabled SAS ...system pulse LEDs 32 system reliability guidelines 37 system-error LED front 15 rear 18 system-locator LED 15, 18 Systems Director, updating 128 systems management 8, 11, 12 T tape drive, installing 60 telephone numbers 132 temperature 7 thermal grease 80 trademarks 133 turning off the server 21 turning on the server 20 146 System x3650 M2 Type 7947...