Get support for IBM x3650 - System M2 - 7947

IBM x3650 Support Question

IBM x3650 Support Question

Find answers below for this question about IBM x3650 - System M2 - 7947.
Need a IBM x3650 manual? We have 1 online manual for this item!
Question posted by phgsangr on August 11th, 2013

Will X3650 M2 Memory Work In X3650 M3?

The person who posted this question about this IBM product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related IBM x3650 Manual Pages

User Guide - Page 5

... riser-card assembly LEDs 35 Installation guidelines 36 System reliability guidelines 37 Working inside the server with the power on 37 Handling static-sensitive devices...63 Installing a second microprocessor 76 Thermal grease 80 Installing a memory module 81 © Copyright IBM Corp. 2010 iii The System x3650 M2 Type 7947 server 1 The IBM Documentation CD 3 Hardware and software ...
User Guide - Page 6

... support 132 Hardware service and support 132 IBM Taiwan product service 132 iv System x3650 M2 Type 7947: Installation and User's Guide Configuring the server 111 Using the Setup utility 112 ... system without using ServerGuide 121 Using the integrated management module 121 Using the USB memory key for VMware hypervisor 123 Using the remote presence capability and blue-screen capture ...
User Guide - Page 17

... superior microprocessor performance, efficient memory management, and flexibility. For more information, see the Warranty and Support Information document on the IBM Documentation CD. Most models contain a ServeRAID SAS controller and are capable of the server. Racks are of technology, best practices, and innovative solutions; The IBM System x3650 M2 Type 7947 server is a 2-U1...
User Guide - Page 23

... 8 GB DIMMs are installed in combination with SVGA and VGA v 16 MB DDR2 SDRAM video memory ServeRAID SAS controller: v ServeRAID-BR10i SAS/SATA Controller that is installed) remote keyboard, video, mouse...two on front, two on page 135. however, the controllers run at 75 MHz. The System x3650 M2 Type 7947 server 7 v For a list of server) Note: Maximum video resolution 1600 x 1200 at x4...
User Guide - Page 25

...configuration - Additionally, you to specific software application programs and hardware configurations. The System x3650 M2 Type 7947 server 9 Mapping the CD or DVD drive, diskette drive, and USB flash drive... see the IBM Systems Director documentation on the integrated USB memory. Uploading a diskette image to the IMM memory and mapping it to a removable media and view the log...
User Guide - Page 26

...html. - v Memory mirroring Memory mirroring improves the ...memory capacity The memory bus supports up the server and install a Windows operating system. v Integrated network support The server comes with two integrated Broadcom Gigabit Ethernet controllers, which you set up to help you can add, remove, or replace hard disk drives without user intervention. 10 System x3650 M2 Type 7947...
User Guide - Page 27

...IBM Virtual Media Key provides remote presence and blue-screen capture capability. The System x3650 M2 Type 7947 server 11 The server supports up to two 675-watt ac power supplies, ... drives v Information and light path diagnostics LED panels v Integrated management module (service processor) v Memory mirroring Chapter 1. The RAS features help to ensure the integrity of the data that is stored ...
User Guide - Page 28

...and creating a configuration plan that can apply those setting to multiple systems 12 System x3650 M2 Type 7947: Installation and User's Guide These common tasks include discovery, inventory, configuration, system ...Circuit (I2C) bus v Upgradeable POST, UEFI, diagnostics, service processor microcode, and read-only memory (ROM) resident code, locally or over the LAN v Vital product data (VPD) on ...
User Guide - Page 37

... system resources and is reserved for information about shutting down the operating system. The System x3650 M2 Type 7947 server 21 v If a power failure occurs while the server is turned on, the ...operating system, the configuration of the server, and the configured PCI options. The amount of memory that all power from the IMM, such as an automatic response to start an orderly shutdown ...
User Guide - Page 48

... server is connected to power, this LED flashes slowly to indicate that the enclosure manager is working correctly. (Trained service technician only) If the server is not flashing, replace the system board. 32 System x3650 M2 Type 7947: Installation and User's Guide Table 8. System pulse LEDs The following illustration shows the light-emitting diodes...
User Guide - Page 52

... you perform any known issues are working. Under Popular links, click Software and device drivers. 4. If you have to turn off the server to disk drives. v Make sure that involve removing or installing adapter cables or non-hot-swap optional devices or components. 36 System x3650 M2 Type 7947: Installation and User's Guide v To...
User Guide - Page 54

... set down the device. Heating reduces indoor humidity and increases static electricity. 38 System x3650 M2 Type 7947: Installation and User's Guide v Avoid dropping any metallic objects, such as paper clips...Do not leave the device where others can damage the server and other grounding system when working inside the server with the power on. This drains static electricity from the package and...
User Guide - Page 62

... first remove the microprocessor 2 air baffle to remove the microprocessor 2 air baffle. Removing the microprocessor 2 air baffle When you work with any air baffle removed might damage server components. 46 System x3650 M2 Type 7947: Installation and User's Guide To remove the microprocessor 2 air baffle, complete the following illustration shows how to access certain...
User Guide - Page 64

... DIMM air baffle, complete the following illustration shows how to access certain components or connectors on page 36. 2. Removing the DIMM air baffle When you work with any air baffle removed might damage server components. 48 System x3650 M2 Type 7947: Installation and User's Guide
User Guide - Page 92

...core microprocessors with the microprocessor to install the second microprocessor. 76 System x3650 M2 Type 7947: Installation and User's Guide v The server supports up to display the...you can install a second microprocessor. v Read the documentation that comes with an integrated memory controller, quick-path interconnect, and shared last cache. v To order additional microprocessor optional ...
User Guide - Page 96

... 0.02 mL each on a clean work surface. 2. Use the thermal-grease syringe to wipe the thermal grease from the microprocessor; To replace damaged or contaminated thermal grease on the syringe. Use a clean area of the thermal grease is found in the syringe. 80 System x3650 M2 Type 7947: Installation and User's Guide Note: 0.01mL...
User Guide - Page 98

... DIMMs is determined by the slowest DIMM in the server. 82 System x3650 M2 Type 7947: Installation and User's Guide The amount of memory that are on a label on the operating system, the configuration of the... DIMM speed as it relates to the operating system. For 32-bit operating systems only: Some memory is reserved for the design of the DIMM d is unavailable to the number of DIMMs in ...
User Guide - Page 100

... in DIMM connectors 3 and 6, which are filled. Figure 2. Figure 1. Connectors on each microprocessor 84 System x3650 M2 Type 7947: Installation and User's Guide Note: You can install DIMMs for microprocessor 1 are associated with each memory channel Memory channel Channel 0 Channel 1 DIMM connectors 1, 2, 3, 9, 10, 11 4, 5, 6, 12, 13, 14 Channel 2 7, 8, 15, 16 The...
User Guide - Page 112

... you are given the opportunity to import the existing RAID configuration to install or remove, do not, the battery pack will not work, and the server might take a few minutes, after the battery is a one-time occurrence. Otherwise, go to fully charge... from the server and set it aside (see "Removing the cover" on page 54). 96 System x3650 M2 Type 7947: Installation and User's Guide
User Guide - Page 120

...remove the USB hypervisor memory key, complete the following steps: 1. If you have other devices to look for information about disabling hypervisor support. 104 System x3650 M2 Type 7947: Installation and User's ...21). 3. Otherwise, go to unlock it from the USB hypervisor connector. Pull the hypervisor memory key from the connector. 6. Turn off the server" on page 43). 4. Read the...

Similar Questions

Ask a New Question
Use the box below to post a new question about this IBM product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

IBM Manuals

Find free IBM x3650 - System M2 - 7947 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

IBM Reviews

View thousands of IBM user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete IBM customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed IBM customer service rankings, employee comments and much more from our sister site.

IBM Recalls

Find comprehensive IBM recall information updated hourly on RecallOwl.com.