User Guide
Page 5
...'s new in Racks and rack features 1 Installing the rack 1 7014-T00 and 7014-T42 racks 1 Installing the 7014-T00 and 7014-T42 racks 1 Completing a parts inventory 2 Positioning the rack 2 Leveling...7014-T00 or 7014-T42 side panels 21 Removing a 7014-T00 or 7014-T42 side panel 21 Replacing a 7014-T00 or 7014-T42 side panel 22 Removing and replacing 7014-T00 or 7014-T42 trim panels 22 Removing the 7014-T00 or 7014-T42 trim panels 22 Replacing the 7014-T00 or 7014-T42...unit 39 Installing the PDU or PDU+ in the side of a rack 39 Setting up power monitoring using the PDU 45 7953-94X and...
...'s new in Racks and rack features 1 Installing the rack 1 7014-T00 and 7014-T42 racks 1 Installing the 7014-T00 and 7014-T42 racks 1 Completing a parts inventory 2 Positioning the rack 2 Leveling...7014-T00 or 7014-T42 side panels 21 Removing a 7014-T00 or 7014-T42 side panel 21 Replacing a 7014-T00 or 7014-T42 side panel 22 Removing and replacing 7014-T00 or 7014-T42 trim panels 22 Removing the 7014-T00 or 7014-T42 trim panels 22 Replacing the 7014-T00 or 7014-T42...unit 39 Installing the PDU or PDU+ in the side of a rack 39 Setting up power monitoring using the PDU 45 7953-94X and...
User Guide
Page 13
... following: v Miscellaneous changes were made to the Installing the PDU or PDU+ in applicable model-specific sections. - For servers, see "Installing the rack security kit" on page 28 after you have installed the rack. © Copyright IBM Corp. 2010, 2013 1 Installing the 7014-T00 and 7014-T42 racks Use this rack, see the installation topics contained...
... following: v Miscellaneous changes were made to the Installing the PDU or PDU+ in applicable model-specific sections. - For servers, see "Installing the rack security kit" on page 28 after you have installed the rack. © Copyright IBM Corp. 2010, 2013 1 Installing the 7014-T00 and 7014-T42 racks Use this rack, see the installation topics contained...
User Guide
Page 51
... the screws (B) you to cover open areas at the right and left side of the following steps: 1. Seal all gaps in the 7014-T00 and 7014-T42 racks. To install the PDU model in a single EIA vertical mounting space in the side of the rack, complete the following options to install your... PDU model: v To install the PDU, go to install the power distribution unit (PDU) or power distribution unit plus (PDU+) can be installed in the ...
... the screws (B) you to cover open areas at the right and left side of the following steps: 1. Seal all gaps in the 7014-T00 and 7014-T42 racks. To install the PDU model in a single EIA vertical mounting space in the side of the rack, complete the following options to install your... PDU model: v To install the PDU, go to install the power distribution unit (PDU) or power distribution unit plus (PDU+) can be installed in the ...
User Guide
Page 52
... the vertical-mounting brackets (A) to the four locations on the rack mounting flanges where the PDU model will be attached. Use nut clips that the power outlets face the rear of the PDU+ 4. Make sure that you attach the brackets so that were provided with the rack mounting kit. 5. Figure 38. See... mounting flanges 40 Power Systems: Racks and rack features Figure 39. Attaching nut clips to the front of the rack. Attach the brackets (A) to the PDU+ with two M3x5 screws (B) per bracket. 3.
... the vertical-mounting brackets (A) to the four locations on the rack mounting flanges where the PDU model will be attached. Use nut clips that the power outlets face the rear of the PDU+ 4. Make sure that you attach the brackets so that were provided with the rack mounting kit. 5. Figure 38. See... mounting flanges 40 Power Systems: Racks and rack features Figure 39. Attaching nut clips to the front of the rack. Attach the brackets (A) to the PDU+ with two M3x5 screws (B) per bracket. 3.
User Guide
Page 53
...provided with the rack mounting kit. 6. Then, turn the connector twist-lock (B) clockwise until it locks into place. Then, while holding the PDU model in place, attach the brackets to the nut clips in the following figure. Racks and rack features 41 Use screws that was provided with... four M5 screws (A) as necessary for key alignment. Aligning the PDU+ with the opening in the side of the rack Attention: You must disconnect the main input power before connecting or disconnecting the input ...
...provided with the rack mounting kit. 6. Then, turn the connector twist-lock (B) clockwise until it locks into place. Then, while holding the PDU model in place, attach the brackets to the nut clips in the following figure. Racks and rack features 41 Use screws that was provided with... four M5 screws (A) as necessary for key alignment. Aligning the PDU+ with the opening in the side of the rack Attention: You must disconnect the main input power before connecting or disconnecting the input ...
User Guide
Page 54
...power cord toward the rack side braces. Then, connect the servers or rack PDUs in the rack to step 5 on page 43. To install the PDU model in a single EIA horizontal mounting space in the rack, if the power cord must exit the rack to connect to a properly wired and grounded... dedicated power source. Read the "Rack safety notices" on the power cord with the PDU model. 9. Choose one of the following options to install your PDU model: v To install the PDU, go to the power outlets on page 45 You can monitor the power status for that device. 10...
...power cord toward the rack side braces. Then, connect the servers or rack PDUs in the rack to step 5 on page 43. To install the PDU model in a single EIA horizontal mounting space in the rack, if the power cord must exit the rack to connect to a properly wired and grounded... dedicated power source. Read the "Rack safety notices" on the power cord with the PDU model. 9. Choose one of the following options to install your PDU model: v To install the PDU, go to the power outlets on page 45 You can monitor the power status for that device. 10...
User Guide
Page 55
...rack. Attaching the long mounting brackets 6. Use nut clips that is the size of a single EIA in the rear of the PDU+ 4. Attach the brackets (A) to the PDU model with two M3 pan-head screws (B) with captive lock washers per bracket. Align the long mounting brackets (A) with the ...holes in the rack where you will install the PDU model. Identify an open mounting space that were provided with two M3x5 screws (B) per bracket. Aligning the vertical-mounting brackets to the front ...
...rack. Attaching the long mounting brackets 6. Use nut clips that is the size of a single EIA in the rear of the PDU+ 4. Attach the brackets (A) to the PDU model with two M3 pan-head screws (B) with captive lock washers per bracket. Align the long mounting brackets (A) with the ...holes in the rack where you will install the PDU model. Identify an open mounting space that were provided with two M3x5 screws (B) per bracket. Aligning the vertical-mounting brackets to the front ...
User Guide
Page 56
...rack flanges. Pushing in slightly on the rack flanges. Use two M6 screws (A) per bracket to attach the brackets to the rack a. Hold the PDU model at a slight angle and carefully insert it into a mounting space that were provided with the rack mounting kit. Secure the long mounting brackets... and the blank filler panel (A) to the specified EIA locations. Figure 44. Align the end of the PDU model with the short mounting brackets with the outside of the long mounting brackets helps clear the brackets from the rack flanges. 8. Attaching the ...
...rack flanges. Pushing in slightly on the rack flanges. Use two M6 screws (A) per bracket to attach the brackets to the rack a. Hold the PDU model at a slight angle and carefully insert it into a mounting space that were provided with the rack mounting kit. Secure the long mounting brackets... and the blank filler panel (A) to the specified EIA locations. Figure 44. Align the end of the PDU model with the short mounting brackets with the outside of the long mounting brackets helps clear the brackets from the rack flanges. 8. Attaching the ...
User Guide
Page 57
... for that secure the long mounting brackets to the power outlets on the outside of the Configuration Utility configuration options are available through the PDU+ web interface. Aligning the connector on the front of the rack flanges. Use the provided cable straps to a power source. Align ... PDUs in the rack if the power cord must disconnect the main input power before connecting or disconnecting the input power cord from the PDU model toward a dedicated power source. Racks and rack features 45 c. Connect the power cord to the long mounting bracket with the rack...
... for that secure the long mounting brackets to the power outlets on the outside of the Configuration Utility configuration options are available through the PDU+ web interface. Aligning the connector on the front of the rack flanges. Use the provided cable straps to a power source. Align ... PDUs in the rack if the power cord must disconnect the main input power before connecting or disconnecting the input power cord from the PDU model toward a dedicated power source. Racks and rack features 45 c. Connect the power cord to the long mounting bracket with the rack...
User Guide
Page 58
... the IP address, network parameters, access control table, and trap receivers table. Using the IBM DPI Configuration Utility: Learn how to use the IBM Distributed power interconnect (DPI) Configuration Utility to the PDU+. Click Start > Programs > Accessories > Communications > HyperTerminal. In the Connect using a ... Systems: Racks and rack features The Properties window is displayed. 4. Set IBM DPI Control Group Set the administrator user name, password, and access protocols. You can access and control the PDU+. Click OK. Connect the DB9-to-RJ-45 cable that you want...
... the IP address, network parameters, access control table, and trap receivers table. Using the IBM DPI Configuration Utility: Learn how to use the IBM Distributed power interconnect (DPI) Configuration Utility to the PDU+. Click Start > Programs > Accessories > Communications > HyperTerminal. In the Connect using a ... Systems: Racks and rack features The Properties window is displayed. 4. Set IBM DPI Control Group Set the administrator user name, password, and access protocols. You can access and control the PDU+. Click OK. Connect the DB9-to-RJ-45 cable that you want...
User Guide
Page 59
... Racks and rack features 47 Settings and Event Log Summary View all uppercase letters). 3. Reset Configuration to window is displayed. Set IBM DPI Information Configure the PDU+ logging interval, refresh rate, and custom name fields for Set the IP Address, Gateway Address and MIB System Group. Enter the...their factory default values. Click OK. In the Password field, type passw0rd (all system settings to use the web interface or access the PDU+ in the address field. Set Superuser Name and Password Set the user name and password of the administrator who will use a web ...
... Racks and rack features 47 Settings and Event Log Summary View all uppercase letters). 3. Reset Configuration to window is displayed. Set IBM DPI Information Configure the PDU+ logging interval, refresh rate, and custom name fields for Set the IP Address, Gateway Address and MIB System Group. Enter the...their factory default values. Click OK. In the Password field, type passw0rd (all system settings to use the web interface or access the PDU+ in the address field. Set Superuser Name and Password Set the user name and password of the administrator who will use a web ...
User Guide
Page 60
... such as the superuser name, password, IP address, date, and time. You can access and control the PDU+, complete the following steps: 1. To change the date and time, complete the following steps: 1. To view... of users who will use a web browser to add users who can only view the PDU+ status or users who can set the date and time manually, synchronize it with the computer time,... or synchronize it with configuring the PDU+. If you with an NTP server. 48 Power Systems: Racks and rack features From the main...
... such as the superuser name, password, IP address, date, and time. You can access and control the PDU+, complete the following steps: 1. To change the date and time, complete the following steps: 1. To view... of users who will use a web browser to add users who can only view the PDU+ status or users who can set the date and time manually, synchronize it with the computer time,... or synchronize it with configuring the PDU+. If you with an NTP server. 48 Power Systems: Racks and rack features From the main...
User Guide
Page 61
... to configure TCP/IP settings. 4. Click Control to add the e-mail addresses. To view the history of all events and a record of the PDU+, complete the following steps: 1. Viewing the event log: You can specify the IP addresses of up to eight trap receivers, the community information,..., click System. 2. Click Email Notification under System to create a list of the events that cause the traps. 3. Click Access Control to set the PDU+ IP address, gateway address, subnet mask, and Domain Name System (DNS) address. 3. Viewing the history log: You can view or change event alerts...
... to configure TCP/IP settings. 4. Click Control to add the e-mail addresses. To view the history of all events and a record of the PDU+, complete the following steps: 1. Viewing the event log: You can specify the IP addresses of up to eight trap receivers, the community information,..., click System. 2. Click Email Notification under System to create a list of the events that cause the traps. 3. Click Access Control to set the PDU+ IP address, gateway address, subnet mask, and Domain Name System (DNS) address. 3. Viewing the history log: You can view or change event alerts...