EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 7
... (QSFP+), and quad small form-factor pluggable 28 (QSFP28) ports. The S4100F-ON Series supports the following sections describe the Dell EMC PowerSwitch S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128TON, S4148T-ON, and S4148U-ON) switch: Topics: • Introduction • Features •... Physical dimensions • LED display • Prerequisites • S4100-ON Series configurations • Luggage tag Introduction The S4128F-ON, S4148F-ON, and S4148FE-ON switches are a one rack unit (RU), full-featured fixed form-factor top-of-rack (ToR) 10/25/40/50/...
... (QSFP+), and quad small form-factor pluggable 28 (QSFP28) ports. The S4100F-ON Series supports the following sections describe the Dell EMC PowerSwitch S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128TON, S4148T-ON, and S4148U-ON) switch: Topics: • Introduction • Features •... Physical dimensions • LED display • Prerequisites • S4100-ON Series configurations • Luggage tag Introduction The S4128F-ON, S4148F-ON, and S4148FE-ON switches are a one rack unit (RU), full-featured fixed form-factor top-of-rack (ToR) 10/25/40/50/...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 20
...to the restricted area. Connect the switch to the appropriate branch circuit protection according to your local electrical codes. ● S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON: Environmental-switch location-continuous temperature range is from 5° to 40°C (50...8226; Cabinet placement • Rack mounting • Switch ground • Fans and airflow • Power • Storing components Site selection Install Dell EMC equipment in outside cabinets. You can only gain access using a special tool, lock, key, or other means of the National Electrical Code ...
...to the restricted area. Connect the switch to the appropriate branch circuit protection according to your local electrical codes. ● S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON: Environmental-switch location-continuous temperature range is from 5° to 40°C (50...8226; Cabinet placement • Rack mounting • Switch ground • Fans and airflow • Power • Storing components Site selection Install Dell EMC equipment in outside cabinets. You can only gain access using a special tool, lock, key, or other means of the National Electrical Code ...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 21
... the power cable before you prepare your switch with a minimum of 5 inches (12.7 cm) of the AC power cord provides a ground path, Dell EMC recommends grounding your equipment rack, ensure that there is connected between the intake and exhaust vents and the cabinet wall. The ground path must... For DC-powered switches, the only way to attach a dedicated ground wire. The fan speed varies based on the S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) support two airflow options: normal and reverse. Ensure that the rack is easily accessible...
... the power cable before you prepare your switch with a minimum of 5 inches (12.7 cm) of the AC power cord provides a ground path, Dell EMC recommends grounding your equipment rack, ensure that there is connected between the intake and exhaust vents and the cabinet wall. The ground path must... For DC-powered switches, the only way to attach a dedicated ground wire. The fan speed varies based on the S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) support two airflow options: normal and reverse. Ensure that the rack is easily accessible...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 23
... are mishandled. Open the container or remove the container top. 3. 4 S4100-ON Series installation To install the S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON), complete the installation procedures in the order presented in this switch. Carefully remove... switch, make sure that the following sites: ● S4148F-ON, S4148T-ON, S4148FE-ON: www.dell.com/support/S4148F-ON/S4148T-ON/S4148FE-ON ● S4128T-ON, S4148T-ON: www.dell.com/support/S4128T-ON/S4148T-ON ● S4148U-ON: www.dell.com/support/S4148U Topics: • Unpack the switch ...
... are mishandled. Open the container or remove the container top. 3. 4 S4100-ON Series installation To install the S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON), complete the installation procedures in the order presented in this switch. Carefully remove... switch, make sure that the following sites: ● S4148F-ON, S4148T-ON, S4148FE-ON: www.dell.com/support/S4148F-ON/S4148T-ON/S4148FE-ON ● S4128T-ON, S4148T-ON: www.dell.com/support/S4128T-ON/S4148T-ON ● S4148U-ON: www.dell.com/support/S4148U Topics: • Unpack the switch ...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 30
... a key that prevents it from the rack or cabinet, press in the correct position. Optics installation The S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch has the following optic configurations: NOTE: For the S4148U-ON, ...Dell EMC representative. NOTE: Do not the use the mounted Ready-Rails as it may cause eye damage. NOTE: When you cable the ports, be sure not to 10.4(0.0) or higher. S4100-ON Series optic configurations Platform Description S4128F-ON ● 28 fixed SFP+ optical ports ● 2 fixed QSFP28 optical ports S4148F...
... a key that prevents it from the rack or cabinet, press in the correct position. Optics installation The S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch has the following optic configurations: NOTE: For the S4148U-ON, ...Dell EMC representative. NOTE: Do not the use the mounted Ready-Rails as it may cause eye damage. NOTE: When you cable the ports, be sure not to 10.4(0.0) or higher. S4100-ON Series optic configurations Platform Description S4128F-ON ● 28 fixed SFP+ optical ports ● 2 fixed QSFP28 optical ports S4148F...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 31
...from the port. For further assistance when replacing a switch, contact your open network installation environment (ONIE)-compatible operating system documentation at www.dell.com/support. CAUTION: ESD damage can occur if components are installed if you do not apply if you remove the original packaging, place...handling the switch and accessories. Switch replacement The following : ● The equipment is properly secured to the S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch after you may be higher than the room temperature, is seated ...
...from the port. For further assistance when replacing a switch, contact your open network installation environment (ONIE)-compatible operating system documentation at www.dell.com/support. CAUTION: ESD damage can occur if components are installed if you do not apply if you remove the original packaging, place...handling the switch and accessories. Switch replacement The following : ● The equipment is properly secured to the S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch after you may be higher than the room temperature, is seated ...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 41
... Networking Hardware Diagnostic Guide found at the following sites: ● S4148F-ON, S4148T-ON, S4148FE-ON: www.dell.com/support/S4148F-ON/S4148T-ON/S4148FE-ON ● S4128T-ON, S4148T-ON: www.dell.com/support/S4128T-ON/S4148T-ON ● S4148U-ON: www.dell.com/support/S4148U Before you install an OS After powering on...
... Networking Hardware Diagnostic Guide found at the following sites: ● S4148F-ON, S4148T-ON, S4148FE-ON: www.dell.com/support/S4148F-ON/S4148T-ON/S4148FE-ON ● S4128T-ON, S4148T-ON: www.dell.com/support/S4128T-ON/S4148T-ON ● S4148U-ON: www.dell.com/support/S4148U Before you install an OS After powering on...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 44
... Table 19. DC power requirements Parameter Minimum and maximum input voltage range Input power at full load Input current at full load Specifications S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148TON: 5° to 40°C (50°F to 104°F), continuously ● S4148U-ON: 5°C to 45°C (50°...
... Table 19. DC power requirements Parameter Minimum and maximum input voltage range Input power at full load Input current at full load Specifications S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148TON: 5° to 40°C (50°F to 104°F), continuously ● S4148U-ON: 5°C to 45°C (50°...
EMC PowerSwitch S4100–ON Series Installation Guide March 2022
Page 45
...Properly shielded and grounded cables and connectors must accept any interference received, including interference that may cause undesired operation. European Community Contact Dell EMC, EMEA - Central Dahlienweg 19 66265 Heusweiler Germany Tel: +49 172 6802630 Email: EMEA Central Sales Specifications 45 Agency ...compliance The S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch complies with the following two conditions: (1) this device may ...
...Properly shielded and grounded cables and connectors must accept any interference received, including interference that may cause undesired operation. European Community Contact Dell EMC, EMEA - Central Dahlienweg 19 66265 Heusweiler Germany Tel: +49 172 6802630 Email: EMEA Central Sales Specifications 45 Agency ...compliance The S4100-ON Series (S4128F-ON, S4148F-ON, S4148FE-ON, S4128T-ON, S4148T-ON, and S4148U-ON) switch complies with the following two conditions: (1) this device may ...