Information Update
Page 3
...adapters can be used to drives in a Dell PowerVault MD1000 enclosure. NOTE: Redundant path connectivity is supported using Dell PowerEdge RAID Controller (PERC) 5/E and PERC 6/E. Figure 1 Redundant Path With One Enclosure Server PowerVault MD1000 storage enclosure Information Update 3... RAID Configuration Update Host-based RAID configuration is not supported on PERC 5/E adapters. With redundant paths, if one path fails, another path can detect and use redundant paths to communicate between the controller and the hard drive...
...adapters can be used to drives in a Dell PowerVault MD1000 enclosure. NOTE: Redundant path connectivity is supported using Dell PowerEdge RAID Controller (PERC) 5/E and PERC 6/E. Figure 1 Redundant Path With One Enclosure Server PowerVault MD1000 storage enclosure Information Update 3... RAID Configuration Update Host-based RAID configuration is not supported on PERC 5/E adapters. With redundant paths, if one path fails, another path can detect and use redundant paths to communicate between the controller and the hard drive...
MD1000 Systems Support Matrix
Page 2
Table of Contents Supported RAID Controllers 3 PERC 5/E Adapter ...3 PERC 6/E Adapter ...4 Supported Servers ...4 Supported Operating Systems 5 Supported Management Software 5 Supported Hard Drives 5 Supported Hardware Configurations 8 2
Table of Contents Supported RAID Controllers 3 PERC 5/E Adapter ...3 PERC 6/E Adapter ...4 Supported Servers ...4 Supported Operating Systems 5 Supported Management Software 5 Supported Hard Drives 5 Supported Hardware Configurations 8 2
MD1000 Systems Support Matrix
Page 5
... Table 3. Refer to see the latest supported Operating Systems for support 5 below contains the latest supported Hard Drives at the time of this document publication. Minimum Supported Management Software for PowerVault MD1000 Systems Software Minimum OMSA Revision Notes Dell OpenManage™ 5.3 The minimum supported OMSA version for minimum supported OMSA level. To determine the latest...
... Table 3. Refer to see the latest supported Operating Systems for support 5 below contains the latest supported Hard Drives at the time of this document publication. Minimum Supported Management Software for PowerVault MD1000 Systems Software Minimum OMSA Revision Notes Dell OpenManage™ 5.3 The minimum supported OMSA version for minimum supported OMSA level. To determine the latest...
MD1000 Systems Support Matrix
Page 6
Supported Hard Drives for PowerVault MD1000 Systems Drive description Maxtor SAS 73 GB 10K RPM Maxtor SAS 146 GB 10K RPM Maxtor SAS 300 GB 10K RPM Maxtor SAS 36 GB 15K RPM ...
Supported Hard Drives for PowerVault MD1000 Systems Drive description Maxtor SAS 73 GB 10K RPM Maxtor SAS 146 GB 10K RPM Maxtor SAS 300 GB 10K RPM Maxtor SAS 36 GB 15K RPM ...
MD1000 Systems Support Matrix
Page 9
... Mode single-HBA host server The PERC 6/E adapter can be used to drives contained in an MD1000 enclosure. With redundant paths, if one path fails, another path can detect and use redundant paths to communicate between the controller and the hard drive. Supported Hardware Configuration Unified Mode Split Mode Two-host configuration Host controller...
... Mode single-HBA host server The PERC 6/E adapter can be used to drives contained in an MD1000 enclosure. With redundant paths, if one path fails, another path can detect and use redundant paths to communicate between the controller and the hard drive. Supported Hardware Configuration Unified Mode Split Mode Two-host configuration Host controller...
Hardware Owners Manual
Page 34
... can be removed and installed without shutting down the enclosure. For information on a flat, secure surface. See your enclosure, you will lose connection to the drives attached to lose communication with nonredundant enclosure management consists of the module (see Figure 3-5). 2 At the same time, pull out on...
... can be removed and installed without shutting down the enclosure. For information on a flat, secure surface. See your enclosure, you will lose connection to the drives attached to lose communication with nonredundant enclosure management consists of the module (see Figure 3-5). 2 At the same time, pull out on...
Hardware Owners Manual
Page 63
Index A alarms, 18 C Cabling, 19 cabling split mode, 20 unified mode, 20 contacting Dell, 54 cooling fan features, 17 troubleshooting, 48 D damaged systems troubleshooting, 46 Dell contacting, 54 E enclosure managing, 25 enclosure management module, 12 bay cover, 36 installing, 35 removing, 34 enclosure ...and replacing, 40 P phone numbers, 54 power supplies troubleshooting, 46 power supply features, 17 R rack-mounted systems installing, 19 H hard drives installing and removing, 30 removing and replacing, 29 S safety, 43 support contacting Dell, 54 system cooling troubleshooting, 47 Index 63
Index A alarms, 18 C Cabling, 19 cabling split mode, 20 unified mode, 20 contacting Dell, 54 cooling fan features, 17 troubleshooting, 48 D damaged systems troubleshooting, 46 Dell contacting, 54 E enclosure managing, 25 enclosure management module, 12 bay cover, 36 installing, 35 removing, 34 enclosure ...and replacing, 40 P phone numbers, 54 power supplies troubleshooting, 46 power supply features, 17 R rack-mounted systems installing, 19 H hard drives installing and removing, 30 removing and replacing, 29 S safety, 43 support contacting Dell, 54 system cooling troubleshooting, 47 Index 63
Hardware Owners Manual
Page 64
T telephone numbers, 54 thermal thresholds, 17 tools needed, 27 troubleshooting, 43 cooling fan, 48 damaged system, 46 external connections, 45 hard drive, 48 power supplies, 46 start-up routine, 43 system cooling, 47 wet system, 45 W warranty, 7 64 Index
T telephone numbers, 54 thermal thresholds, 17 tools needed, 27 troubleshooting, 43 cooling fan, 48 damaged system, 46 external connections, 45 hard drive, 48 power supplies, 46 start-up routine, 43 system cooling, 47 wet system, 45 W warranty, 7 64 Index
Getting Started Guide: (English, Brazilian Portuguese, and Spanish)
Page 5
...system include: • Enclosure storage in unified mode for a total of 45 hard drives • In-band enclosure management provided through SCSI enclosure services (SES) • RAID and system management using Dell OpenManage™ Server Administrator Storage Management Service • Four sensors for monitoring ... updated readme can be viewed from the Dell website at support.dell.com.) Getting Started With Your System 3 System Features This section describes the major hardware and software features of your system and how to 15 hard drives - It also provides information about other ...
...system include: • Enclosure storage in unified mode for a total of 45 hard drives • In-band enclosure management provided through SCSI enclosure services (SES) • RAID and system management using Dell OpenManage™ Server Administrator Storage Management Service • Four sensors for monitoring ... updated readme can be viewed from the Dell website at support.dell.com.) Getting Started With Your System 3 System Features This section describes the major hardware and software features of your system and how to 15 hard drives - It also provides information about other ...
Getting Started Guide: (English, Brazilian Portuguese, and Spanish)
Page 10
...) at speeds of 10K or 15K rpm (See your system readme file for supported disk capacities.) SATA hard drives up to 15 1-inch-by-3.5-inch SATA hot-plug hard drives (3.0 Gbps) at speeds of EMM connectors (6 connectors each EMM) • 1 control panel connector for front LEDs ...the host • 1 SAS "OUT" connector for expansion to an additional enclosure Serial connector (per EMM Backplane Board Connectors • 15 SAS hard-drive connectors • 2 power supply/cooling fan module connectors • 2 sets of 7.2K rpm. Connectivity Configurations support for either of the following ...
...) at speeds of 10K or 15K rpm (See your system readme file for supported disk capacities.) SATA hard drives up to 15 1-inch-by-3.5-inch SATA hot-plug hard drives (3.0 Gbps) at speeds of EMM connectors (6 connectors each EMM) • 1 control panel connector for front LEDs ...the host • 1 SAS "OUT" connector for expansion to an additional enclosure Serial connector (per EMM Backplane Board Connectors • 15 SAS hard-drive connectors • 2 power supply/cooling fan module connectors • 2 sets of 7.2K rpm. Connectivity Configurations support for either of the following ...
Getting Started Guide: (English, Brazilian Portuguese, and Spanish)
Page 11
... LED indicator for system status • 2 single-color LED indicators for power and split mode Hard-drive carrier • 1 single-color activity LED • 1 two-color LED status indicator per drive EMM 3 two-color LED status indicators, one each for the two EMM SAS ports and one...Heat dissipation 200 W Voltage 100-240 V rated (actual 90-264 V) Frequency 47-63 Hz Amperage 7.2 A at 100 V, 3.6 A at 200 V Available Hard-Drive Power (Per Slot) Supported hard-drive power consumption up to 1.3 A at +12 V up to 1.5 A at +5 V Physical Height 13.11 cm (5.16 inches) Width 44.63 cm (...
... LED indicator for system status • 2 single-color LED indicators for power and split mode Hard-drive carrier • 1 single-color activity LED • 1 two-color LED status indicator per drive EMM 3 two-color LED status indicators, one each for the two EMM SAS ports and one...Heat dissipation 200 W Voltage 100-240 V rated (actual 90-264 V) Frequency 47-63 Hz Amperage 7.2 A at 100 V, 3.6 A at 200 V Available Hard-Drive Power (Per Slot) Supported hard-drive power consumption up to 1.3 A at +12 V up to 1.5 A at +5 V Physical Height 13.11 cm (5.16 inches) Width 44.63 cm (...
Getting Started Guide: (English, Simplified Chinese, French, German, Greek, Hebrew, Polish, Russian, Turkish and Spanish)
Page 5
...three daisy-chained storage enclosures in unified mode for a total of 45 hard drives • In-band enclosure management provided through SCSI enclosure services (SES) • RAID and system management using Dell OpenManage™ Server Administrator Storage Management Service • Four sensors for monitoring...technical assistance. Unified mode for either 15 3.5-inch, hot-plug, 3.0-Gbps, serial-attached SCSI (SAS) hard drives or 15 3.5-inch, hot-plug, 3.0-Gbps, Serial ATA (SATA) hard drives • Host-based RAID support via a PERC 5/E adapter • Redundant hot-plug power supply and...
...three daisy-chained storage enclosures in unified mode for a total of 45 hard drives • In-band enclosure management provided through SCSI enclosure services (SES) • RAID and system management using Dell OpenManage™ Server Administrator Storage Management Service • Four sensors for monitoring...technical assistance. Unified mode for either 15 3.5-inch, hot-plug, 3.0-Gbps, serial-attached SCSI (SAS) hard drives or 15 3.5-inch, hot-plug, 3.0-Gbps, Serial ATA (SATA) hard drives • Host-based RAID support via a PERC 5/E adapter • Redundant hot-plug power supply and...
Getting Started Guide: (English, Simplified Chinese, French, German, Greek, Hebrew, Polish, Russian, Turkish and Spanish)
Page 10
...for either of the following configurations: • unified mode for direct connectivity to 15 hard drives • split mode with dual EMMs providing a direct connectivity to drives 0 though 6 and a separate direct connectivity to drives 7 though 14 Enclosure Management Modules EMMs 1 or 2 modules Sensors 1 sensor per..." connector for connection to the host • 1 SAS "OUT" connector for supported disk capacities.) SATA hard drives up to 15 1-inch-by -3.5-inch SATA hot-plug hard drives (3.0 Gbps) at speeds of 10K or 15K rpm (See your system readme file for expansion to the system...
...for either of the following configurations: • unified mode for direct connectivity to 15 hard drives • split mode with dual EMMs providing a direct connectivity to drives 0 though 6 and a separate direct connectivity to drives 7 though 14 Enclosure Management Modules EMMs 1 or 2 modules Sensors 1 sensor per..." connector for connection to the host • 1 SAS "OUT" connector for supported disk capacities.) SATA hard drives up to 15 1-inch-by -3.5-inch SATA hot-plug hard drives (3.0 Gbps) at speeds of 10K or 15K rpm (See your system readme file for expansion to the system...
Getting Started Guide: (English, Simplified Chinese, French, German, Greek, Hebrew, Polish, Russian, Turkish and Spanish)
Page 11
... LED indicator for system status • 2 single-color LED indicators for power and split mode Hard-drive carrier • 1 single-color activity LED • 1 two-color LED status indicator per drive EMM 3 two-color LED status indicators, one each for the two EMM SAS ports and one...Heat dissipation 200 W Voltage 100-240 V rated (actual 90-264 V) Frequency 47-63 Hz Amperage 7.2 A at 100 V, 3.6 A at 200 V Available Hard-Drive Power (Per Slot) Supported hard-drive power consumption up to 1.3 A at +12 V up to 1.5 A at +5 V Physical Height 13.11 cm (5.16 inches) Width 44.63 cm (...
... LED indicator for system status • 2 single-color LED indicators for power and split mode Hard-drive carrier • 1 single-color activity LED • 1 two-color LED status indicator per drive EMM 3 two-color LED status indicators, one each for the two EMM SAS ports and one...Heat dissipation 200 W Voltage 100-240 V rated (actual 90-264 V) Frequency 47-63 Hz Amperage 7.2 A at 100 V, 3.6 A at 200 V Available Hard-Drive Power (Per Slot) Supported hard-drive power consumption up to 1.3 A at +12 V up to 1.5 A at +5 V Physical Height 13.11 cm (5.16 inches) Width 44.63 cm (...
Getting Started Guide (English, Japanese, Korean, Simplified Chinese, and Traditional Chinese)
Page 5
...system include: • Enclosure storage in unified mode for a total of 45 hard drives • In-band enclosure management provided through SCSI enclosure services (SES) • RAID and system management using Dell OpenManage™ Server Administrator Storage Management Service • Four sensors for monitoring ...position switch for setting the enclosure mode (unified or split mode) • Support for up your system and how to 15 hard drives - System Features This section describes the major hardware and software features of your system's readme file for supported systems. An updated...
...system include: • Enclosure storage in unified mode for a total of 45 hard drives • In-band enclosure management provided through SCSI enclosure services (SES) • RAID and system management using Dell OpenManage™ Server Administrator Storage Management Service • Four sensors for monitoring ...position switch for setting the enclosure mode (unified or split mode) • Support for up your system and how to 15 hard drives - System Features This section describes the major hardware and software features of your system's readme file for supported systems. An updated...
Getting Started Guide (English, Japanese, Korean, Simplified Chinese, and Traditional Chinese)
Page 10
...either of the following configurations: • unified mode for direct connectivity to 15 hard drives • split mode with dual EMMs providing a direct connectivity to drives 0 though 6 and a separate direct connectivity to drives 7 though 14 Enclosure Management Modules EMMs 1 or 2 modules Sensors 1 sensor ...OUT" connector for expansion to the system backplane is provided through an interposer assembly. Technical Specifications Drives SAS hard drives up to 15 1-inch-by-3.5-inch SAS hot-plug hard drives (3.0 Gbps) at speeds of 10K or 15K rpm (See your system readme file for ...
...either of the following configurations: • unified mode for direct connectivity to 15 hard drives • split mode with dual EMMs providing a direct connectivity to drives 0 though 6 and a separate direct connectivity to drives 7 though 14 Enclosure Management Modules EMMs 1 or 2 modules Sensors 1 sensor ...OUT" connector for expansion to the system backplane is provided through an interposer assembly. Technical Specifications Drives SAS hard drives up to 15 1-inch-by-3.5-inch SAS hot-plug hard drives (3.0 Gbps) at speeds of 10K or 15K rpm (See your system readme file for ...
Getting Started Guide (English, Japanese, Korean, Simplified Chinese, and Traditional Chinese)
Page 11
... LED indicator for system status • 2 single-color LED indicators for power and split mode Hard-drive carrier • 1 single-color activity LED • 1 two-color LED status indicator per drive EMM 3 two-color LED status indicators, one each for the two EMM SAS ports and one...Heat dissipation 200 W Voltage 100-240 V rated (actual 90-264 V) Frequency 47-63 Hz Amperage 7.2 A at 100 V, 3.6 A at 200 V Available Hard-Drive Power (Per Slot) Supported hard-drive power consumption up to 1.3 A at +12 V up to 1.5 A at +5 V Physical Height 13.11 cm (5.16 inches) Width 44.63 cm (...
... LED indicator for system status • 2 single-color LED indicators for power and split mode Hard-drive carrier • 1 single-color activity LED • 1 two-color LED status indicator per drive EMM 3 two-color LED status indicators, one each for the two EMM SAS ports and one...Heat dissipation 200 W Voltage 100-240 V rated (actual 90-264 V) Frequency 47-63 Hz Amperage 7.2 A at 100 V, 3.6 A at 200 V Available Hard-Drive Power (Per Slot) Supported hard-drive power consumption up to 1.3 A at +12 V up to 1.5 A at +5 V Physical Height 13.11 cm (5.16 inches) Width 44.63 cm (...