EMC PowerEdge Servers Troubleshooting Guide
Page 8
... For information about installing and securing www.dell.com/poweredgemanuals the system into a rack, see the Dell OpenManage Server Administrator User's Guide. www.dell.com/serviceabilitytools 8 Introduction Click the documentation link that is provided in the Location column in the table. 2. On the Product Support page, click Manuals & documents. • Using search engines: ○...
... For information about installing and securing www.dell.com/poweredgemanuals the system into a rack, see the Dell OpenManage Server Administrator User's Guide. www.dell.com/serviceabilitytools 8 Introduction Click the documentation link that is provided in the Location column in the table. 2. On the Product Support page, click Manuals & documents. • Using search engines: ○...
EMC PowerEdge Servers Troubleshooting Guide
Page 21
...PSA and ePSA) Error message Description Steps ePSA 2000-0144 PSA 1000-0145 ePSA 2000-0145 PSA Hard Drive - If failure continues, contact Dell Technical Support PSA 1000-0146 ePSA 2000-0146 Hard Drive - Repeat the PSA diagnostics. 4. BIST --(s) ePSA Optical Drive - Turn off...the PSA diagnostics. 6. timeout waiting for your systems Owners Manual at both ends of the data 1. Reseat the drive, reseat the data cable and power connection at www.dell.com/ poweredgemanuals. 4. If failure continues, contact Dell Technical Support PSA 1000-0147 ePSA 2000-0147 PSA Optical ...
...PSA and ePSA) Error message Description Steps ePSA 2000-0144 PSA 1000-0145 ePSA 2000-0145 PSA Hard Drive - If failure continues, contact Dell Technical Support PSA 1000-0146 ePSA 2000-0146 Hard Drive - Repeat the PSA diagnostics. 4. BIST --(s) ePSA Optical Drive - Turn off...the PSA diagnostics. 6. timeout waiting for your systems Owners Manual at both ends of the data 1. Reseat the drive, reseat the data cable and power connection at www.dell.com/ poweredgemanuals. 4. If failure continues, contact Dell Technical Support PSA 1000-0147 ePSA 2000-0147 PSA Optical ...
EMC PowerEdge Servers Troubleshooting Guide
Page 55
Reseat the cable at the prompt to perform a manual rebuild of multiple physical disks. 8. Press Ctrl + R during ...missing. press to open PERC BIOS Configuration Utility. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to import the foreign configuration. 7. Figure 13. If the problem is imported.... Mgmt (Physical Disk Management) screen and check if any hard drives are present in the Dell EMC PowerEdge Servers Troubleshooting Guide. Checking hard drive status in the PERC BIOS Steps 1. Reseat the controller card. 4. ...
Reseat the cable at the prompt to perform a manual rebuild of multiple physical disks. 8. Press Ctrl + R during ...missing. press to open PERC BIOS Configuration Utility. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to import the foreign configuration. 7. Figure 13. If the problem is imported.... Mgmt (Physical Disk Management) screen and check if any hard drives are present in the Dell EMC PowerEdge Servers Troubleshooting Guide. Checking hard drive status in the PERC BIOS Steps 1. Reseat the controller card. 4. ...
EMC PowerEdge Servers Troubleshooting Guide
Page 58
... persists, see the Getting help section. 58 Troubleshooting hardware issues Damage due to perform a manual rebuild of data. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to servicing that a power cable is properly connected to a cable pull...an optical drive Prerequisites CAUTION: Many repairs may only be done by a certified service technician. Ensure that is not authorized by Dell is imported. Reseat the Drives and ensure that the integrated SATA controller and the drive's SATA port are present in your product...
... persists, see the Getting help section. 58 Troubleshooting hardware issues Damage due to perform a manual rebuild of data. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to servicing that a power cable is properly connected to a cable pull...an optical drive Prerequisites CAUTION: Many repairs may only be done by a certified service technician. Ensure that is not authorized by Dell is imported. Reseat the Drives and ensure that the integrated SATA controller and the drive's SATA port are present in your product...
EMC PowerEdge Servers Troubleshooting Guide
Page 60
...After installing a power supply unit, allow several interfaces. If the problem persists, see Lifecycle Controller User's Guide available at www.dell.com/ poweredgemanuals. Here we are creating a RAID volume using PERC How to create RAID volumes If your system, ensure that .... In the left pane, click Hardware Configuration. 3. Troubleshooting power source problems Steps 1. Plug in the Installation and Service Manual available at www.dell.com/idracmanuals . 2. Ensure that no loose connections exist. Troubleshooting power supply unit problems Steps 1. RAID volumes can be ...
...After installing a power supply unit, allow several interfaces. If the problem persists, see Lifecycle Controller User's Guide available at www.dell.com/ poweredgemanuals. Here we are creating a RAID volume using PERC How to create RAID volumes If your system, ensure that .... In the left pane, click Hardware Configuration. 3. Troubleshooting power source problems Steps 1. Plug in the Installation and Service Manual available at www.dell.com/idracmanuals . 2. Ensure that no loose connections exist. Troubleshooting power supply unit problems Steps 1. RAID volumes can be ...
EMC PowerEdge Servers Troubleshooting Guide
Page 62
...rebuild operation starts automatically after multiple physical disks become simultaneously inaccessible About this task Some controllers enable you to perform a manual rebuild of importing foreign configuration imports all the drives are imported. If more than one side of a mirror in ... configuration contains only one foreign virtual disk is imported in a Degraded state and can use the BIOS Configuration Utility or Dell OpenManage storage management application to import a foreign configuration so that all virtual disks residing on adapter. When a foreign configuration...
...rebuild operation starts automatically after multiple physical disks become simultaneously inaccessible About this task Some controllers enable you to perform a manual rebuild of importing foreign configuration imports all the drives are imported. If more than one side of a mirror in ... configuration contains only one foreign virtual disk is imported in a Degraded state and can use the BIOS Configuration Utility or Dell OpenManage storage management application to import a foreign configuration so that all virtual disks residing on adapter. When a foreign configuration...
EMC PowerEdge Servers Troubleshooting Guide
Page 72
.../volumes/datastore1/ 9. NOTE: Create boot virtual disk only from a disk drive populated across slots 0-3 of the system. For slot information, see the server Owner's Manual at www.dell.com/poweredgemanuals. Copy MegaSAS.log to configure a virtual disk as the boot device. The Configuration Wizards window is displayed. 2. Launch the Lifecycle Controller home... supported PERC RAID controllers with Datastore Browser. Steps 1. Log creation 8. Log file in Datastore Browser Now the logs are exported on ESXi hosts on the Dell 13th generation PowerEdge servers.
.../volumes/datastore1/ 9. NOTE: Create boot virtual disk only from a disk drive populated across slots 0-3 of the system. For slot information, see the server Owner's Manual at www.dell.com/poweredgemanuals. Copy MegaSAS.log to configure a virtual disk as the boot device. The Configuration Wizards window is displayed. 2. Launch the Lifecycle Controller home... supported PERC RAID controllers with Datastore Browser. Steps 1. Log creation 8. Log file in Datastore Browser Now the logs are exported on ESXi hosts on the Dell 13th generation PowerEdge servers.
EMC PowerEdge Servers Troubleshooting Guide
Page 78
... specific period of the following circumstances: • The physical disk is no other background tasks are dedicated to Auto mode, you to Manual does not initiate the Patrol Read task. The controller adjusts the amount of system resources dedicated for the failure is finished. When the... runs again within a specified period. Based on how often the Patrol Read task runs when in Auto mode, see your controller documentation. • Manual - To set Patrol Read mode Select the desired Patrol Read Mode option. The options available are : • Auto - NOTE: For more information...
... specific period of the following circumstances: • The physical disk is no other background tasks are dedicated to Auto mode, you to Manual does not initiate the Patrol Read task. The controller adjusts the amount of system resources dedicated for the failure is finished. When the... runs again within a specified period. Based on how often the Patrol Read task runs when in Auto mode, see your controller documentation. • Manual - To set Patrol Read mode Select the desired Patrol Read Mode option. The options available are : • Auto - NOTE: For more information...
EMC PowerEdge Servers Troubleshooting Guide
Page 84
... Information about the RAID arrays including configuration information, disk members, role of data caused by a double fault condition. To perform a manual Learn Cycle, select Start Learn Cycle from the Battery Tasks drop-down menu in a non-functioning offline state. NVCache memory contains both...to a rebuilding drive. • Double Fault does not exist (Data is lost ). RAID puncture A RAID puncture is a feature of Dell PowerEdge RAID Controller (PERC) designed to allow the controller to the individual hard drives. RAID punctures can essentially be written to restore the redundancy ...
... Information about the RAID arrays including configuration information, disk members, role of data caused by a double fault condition. To perform a manual Learn Cycle, select Start Learn Cycle from the Battery Tasks drop-down menu in a non-functioning offline state. NVCache memory contains both...to a rebuilding drive. • Double Fault does not exist (Data is lost ). RAID puncture A RAID puncture is a feature of Dell PowerEdge RAID Controller (PERC) designed to allow the controller to the individual hard drives. RAID punctures can essentially be written to restore the redundancy ...
EMC PowerEdge Servers Troubleshooting Guide
Page 92
...to replace the failed physical disk without interrupting the system or requiring your intervention. Global hot spares must be assigned and unassigned manually. NOTE: When deleting virtual disks, all assigned global hot spares may be familiar with the size requirements and other considerations associated...NOTE: If the Lifecycle Controller settings are not assigned to function as needed. You can also assign more information, see the Dell EMC OpenManage Software Support Matrix available on the support site. Executing this task on the global hot spare, it continues to specific...
...to replace the failed physical disk without interrupting the system or requiring your intervention. Global hot spares must be assigned and unassigned manually. NOTE: When deleting virtual disks, all assigned global hot spares may be familiar with the size requirements and other considerations associated...NOTE: If the Lifecycle Controller settings are not assigned to function as needed. You can also assign more information, see the Dell EMC OpenManage Software Support Matrix available on the support site. Executing this task on the global hot spare, it continues to specific...
EMC PowerEdge Servers Troubleshooting Guide
Page 99
... and methods. Alternatively, bypass the switch and connect the system directly to share applications and resources with users. NOTE: For more information, see the iDRAC manuals at will. USB driver is not recognizing USB in SNMP Configuration page. • To disable SNMP discovery uncheck the Enable SNMP discovery • For discovery... combinations of remote device. • Click Finish. You can increase and decrease Remote Desktop Web Access, Gateway, Connection Broker and Session Host servers at www.dell.com/idracmanuals Lifecycle Controller is not recognized on .
... and methods. Alternatively, bypass the switch and connect the system directly to share applications and resources with users. NOTE: For more information, see the iDRAC manuals at will. USB driver is not recognizing USB in SNMP Configuration page. • To disable SNMP discovery uncheck the Enable SNMP discovery • For discovery... combinations of remote device. • Click Finish. You can increase and decrease Remote Desktop Web Access, Gateway, Connection Broker and Session Host servers at www.dell.com/idracmanuals Lifecycle Controller is not recognized on .
EMC PowerEdge Servers Troubleshooting Guide
Page 103
...flea power to resolve the issue. 2. Error messages may only be reported correctly if the static flea power is displayed at www.dell.com/poweredgemanuals. NOTE: Ensure that are shipped with your product documentation, or as authorized in the POST mode. Troubleshooting operating system ...parts, always turn on troubleshooting iDRAC issues. During this period, a message on removing and installing hardware components, see your system's Owner's Manual at POST during the POST. This allows the server to boot to power up to the latest firmware. error message is not fully ...
...flea power to resolve the issue. 2. Error messages may only be reported correctly if the static flea power is displayed at www.dell.com/poweredgemanuals. NOTE: Ensure that are shipped with your product documentation, or as authorized in the POST mode. Troubleshooting operating system ...parts, always turn on troubleshooting iDRAC issues. During this period, a message on removing and installing hardware components, see your system's Owner's Manual at POST during the POST. This allows the server to boot to power up to the latest firmware. error message is not fully ...
EMC PowerEdge Servers Troubleshooting Guide
Page 104
... fails to POST, proceed to POST the server. Bring the server to POST configuration for assistance. If you identify the defective part, contact Dell Technical Support with information about the defective part. Disconnect the hard drives, optical drives, and tape drives from the server including the power cable... Press and hold the power button for Business: Steps 1. For modular servers, the minimum to POST configuration is lit amber, see your system's Owner's manual at a time until the defective hard drives are unable to identify the defective part, go to the next step. 8.
... fails to POST, proceed to POST the server. Bring the server to POST configuration for assistance. If you identify the defective part, contact Dell Technical Support with information about the defective part. Disconnect the hard drives, optical drives, and tape drives from the server including the power cable... Press and hold the power button for Business: Steps 1. For modular servers, the minimum to POST configuration is lit amber, see your system's Owner's manual at a time until the defective hard drives are unable to identify the defective part, go to the next step. 8.
EMC PowerEdge Servers Troubleshooting Guide
Page 108
...Settings screen is set to Disable. Why does Windows OS installation using Lifecycle Controller (LC) or manually, may display a blank screen while booting to install Windows Server 2012 R2 operating system on an... iSCSI or FCOE LUN, you may see a failure either using Lifecycle Controller, on PowerEdge Servers fail at first boot. 108 Troubleshooting operating system issues NOTE: By default, the USB 3.0...in System Setup is set to Enable. NOTE: Ensure that there are available at www.dell.com/support. 2. Why does Windows Server 2008 R2 SP1 display a blank screen in UEFI ...
...Settings screen is set to Disable. Why does Windows OS installation using Lifecycle Controller (LC) or manually, may display a blank screen while booting to install Windows Server 2012 R2 operating system on an... iSCSI or FCOE LUN, you may see a failure either using Lifecycle Controller, on PowerEdge Servers fail at first boot. 108 Troubleshooting operating system issues NOTE: By default, the USB 3.0...in System Setup is set to Enable. NOTE: Ensure that there are available at www.dell.com/support. 2. Why does Windows Server 2008 R2 SP1 display a blank screen in UEFI ...
EMC PowerEdge Servers Troubleshooting Guide
Page 111
... Why are in the Maintenance mode. To Reboot, perform the following steps. You must manually power on Microsoft Windows operating systems. • vSphere Management Assistant (vMA) - Unable... to allocate storage space to attain the protected state. Configuration backup and restore procedures Dell EMC recommends that the hard drives have installed the Windows or Linux management Application Programming ...license code (host serial number). This is added to shut down . Affected systems include PowerEdge systems R815, R715 and M915. Before you want to the log. Backing up your...
... Why are in the Maintenance mode. To Reboot, perform the following steps. You must manually power on Microsoft Windows operating systems. • vSphere Management Assistant (vMA) - Unable... to allocate storage space to attain the protected state. Configuration backup and restore procedures Dell EMC recommends that the hard drives have installed the Windows or Linux management Application Programming ...license code (host serial number). This is added to shut down . Affected systems include PowerEdge systems R815, R715 and M915. Before you want to the log. Backing up your...
EMC PowerEdge Servers Troubleshooting Guide
Page 114
... USB Drive Drive 25. Export Server Profile Using USB Drive USB Drive 7. Dell Lifecycle Controller - Dell Lifecycle Controller - Break LC - Break Mirror Mirror 13. Dell Lifecycle Controller - Dell Lifecycle Controller RAID Configuration LC RAID Configuration 15. Dell Lifecycle Controller - OS Deployment Manual Installation OS Deployment Manual Installation 17. Unattended Install Using - OS Deployment - Install Operating System with...
... USB Drive Drive 25. Export Server Profile Using USB Drive USB Drive 7. Dell Lifecycle Controller - Dell Lifecycle Controller - Break LC - Break Mirror Mirror 13. Dell Lifecycle Controller - Dell Lifecycle Controller RAID Configuration LC RAID Configuration 15. Dell Lifecycle Controller - OS Deployment Manual Installation OS Deployment Manual Installation 17. Unattended Install Using - OS Deployment - Install Operating System with...
EMC PowerEdge RAID Controller S140 Users Guide
Page 11
... from a single graphical or command-line interface without using controller BIOS utilities. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the Lifecycle Controller User's Guide at dell.com/manuals. See Setting the NVMe PCIe SSDs to RAID mode on NVMe PCIe SSDs are supported. Overview...not supported in iDRAC, see the OpenManage Storage Management User's Guide at www.dell.com/idracmanuals. NOTE: Mixing NVMe PCIe SSDs and SATA drives is supported. See UEFI RAID configuration utility on PowerEdge NVMe 2.5 - RAID configurations on page 38 • OpenManage Storage Management-This ...
... from a single graphical or command-line interface without using controller BIOS utilities. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the Lifecycle Controller User's Guide at dell.com/manuals. See Setting the NVMe PCIe SSDs to RAID mode on NVMe PCIe SSDs are supported. Overview...not supported in iDRAC, see the OpenManage Storage Management User's Guide at www.dell.com/idracmanuals. NOTE: Mixing NVMe PCIe SSDs and SATA drives is supported. See UEFI RAID configuration utility on PowerEdge NVMe 2.5 - RAID configurations on page 38 • OpenManage Storage Management-This ...
EMC PowerEdge RAID Controller S140 Users Guide
Page 12
... host with additional methods to drive mixing restrictions for the PERC S140. • The replacement disk must be of the disk group. it is the manual replacement of a device. For example, you cannot mix an HDD and an NVMe PCIe SSD in OS mode. Hot-swapping is supported only in the...
... host with additional methods to drive mixing restrictions for the PERC S140. • The replacement disk must be of the disk group. it is the manual replacement of a device. For example, you cannot mix an HDD and an NVMe PCIe SSD in OS mode. Hot-swapping is supported only in the...
EMC PowerEdge RAID Controller S140 Users Guide
Page 13
..., hot-swapping two or more NVMe PCIe SSDs simultaneously is not supported. NOTE: Ensure that are factors related to read from the Dell EMC open manage console. NOTE: The system does not have to remove Non-RAID NVMe volume from the surviving mirrored physical disk(s). In... virtual disk remains functional and data is configured for this feature). • Parity generation and checking (RAID 5 only). • Hot-swap manual replacement of the NVMe PCIe SSDs in values and determine whether the values are available with a backplane that allows hot- NOTE: Recommended minimum version...
..., hot-swapping two or more NVMe PCIe SSDs simultaneously is not supported. NOTE: Ensure that are factors related to read from the Dell EMC open manage console. NOTE: The system does not have to remove Non-RAID NVMe volume from the surviving mirrored physical disk(s). In... virtual disk remains functional and data is configured for this feature). • Parity generation and checking (RAID 5 only). • Hot-swap manual replacement of the NVMe PCIe SSDs in values and determine whether the values are available with a backplane that allows hot- NOTE: Recommended minimum version...
EMC PowerEdge RAID Controller S140 Users Guide
Page 18
... electrical outlet and peripherals. Locate the connectors J_SATA A and J_SATA B on removing and reinstalling system parts, see the PowerEdge systems owner's manuals at dell.com/ poweredgemanuals. 1. Read and follow the safety instructions that you always use a static mat and static strap while working... the J_SATA A and J_SATA B connectors on the AHCI devices to the drives available on components in your system owner's manual at dell.com/poweredgemanuals. Remove the system cover. 3. You should only perform troubleshooting and simple repairs as directed by a certified service...
... electrical outlet and peripherals. Locate the connectors J_SATA A and J_SATA B on removing and reinstalling system parts, see the PowerEdge systems owner's manuals at dell.com/ poweredgemanuals. 1. Read and follow the safety instructions that you always use a static mat and static strap while working... the J_SATA A and J_SATA B connectors on the AHCI devices to the drives available on components in your system owner's manual at dell.com/poweredgemanuals. Remove the system cover. 3. You should only perform troubleshooting and simple repairs as directed by a certified service...