Installation and Service Manual
Page 3
... System weight...31 Processor specifications...32 PSU specifications...32 Supported operating systems...33 Cooling fan specifications...33 System battery specifications...34 Expansion card riser specifications...34 Memory specifications...35 Storage controller specifications...36 Drives...36 Ports and connectors specifications...37 USB ports specifications...37 NIC port specifications...37 Serial connector specifications...37 VGA ports specifications...37 Video specifications...38 Environmental specifications...38 Thermal restriction...
... System weight...31 Processor specifications...32 PSU specifications...32 Supported operating systems...33 Cooling fan specifications...33 System battery specifications...34 Expansion card riser specifications...34 Memory specifications...35 Storage controller specifications...36 Drives...36 Ports and connectors specifications...37 USB ports specifications...37 NIC port specifications...37 Serial connector specifications...37 VGA ports specifications...37 Video specifications...38 Environmental specifications...38 Thermal restriction...
Installation and Service Manual
Page 10
..., and the iDRAC Direct status LED. Front view of 16 x 2.5-inch drive system Figure 3. Features available on . NOTE: For drive slot numbers, see the Technical specification section. 10 System overview Front view of the system Item Ports, panels, and slots Icon Description 1 Left control panel N/A Contains the system health, system ID...
..., and the iDRAC Direct status LED. Front view of 16 x 2.5-inch drive system Figure 3. Features available on . NOTE: For drive slot numbers, see the Technical specification section. 10 System overview Front view of the system Item Ports, panels, and slots Icon Description 1 Left control panel N/A Contains the system health, system ID...
Installation and Service Manual
Page 12
...Item Indicator, button, or connector Icon Description For more information, see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. NOTE: For more information about ports, panels, and slots, ...see the System diagnostics and indicator codes section. NOTE: Press the power button to your laptop or tablet. NOTE: You can configure iDRAC Direct by cable quality. NOTE: For more information about the indicator codes, see the Technical specification...
...Item Indicator, button, or connector Icon Description For more information, see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. NOTE: For more information about ports, panels, and slots, ...see the System diagnostics and indicator codes section. NOTE: Press the power button to your laptop or tablet. NOTE: You can configure iDRAC Direct by cable quality. NOTE: For more information about the indicator codes, see the Technical specification...
Installation and Service Manual
Page 17
...stops responding during system boot), press and hold the System ID button for more information , see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. The NIC ports are integrated on the iDRAC setup page by pressing F2 during POST, press ... ports, panels, and slots, see the Expansion card installation guidelines section. 3 BOSS module N/A BOSS module for more information , see the Technical specification section. The System Identification (ID) button is the primary PSU of the system. PSU2 is the secondary PSU of the system with 4 x ...
...stops responding during system boot), press and hold the System ID button for more information , see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. The NIC ports are integrated on the iDRAC setup page by pressing F2 during POST, press ... ports, panels, and slots, see the Expansion card installation guidelines section. 3 BOSS module N/A BOSS module for more information , see the Technical specification section. The System Identification (ID) button is the primary PSU of the system. PSU2 is the secondary PSU of the system with 4 x ...
Installation and Service Manual
Page 29
... rack mounting flanges. ● Rail depth with your system, see the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix available at https://i.dell.com/sites/csdocuments/Business_solutions_engineeringDocs_Documents/en/rail-rack-matrix.pdf. Rail sizing and rack compatibility matrix For specific information about rail types and their functionalities. ● Rail adjustability range for...
... rack mounting flanges. ● Rail depth with your system, see the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix available at https://i.dell.com/sites/csdocuments/Business_solutions_engineeringDocs_Documents/en/rail-rack-matrix.pdf. Rail sizing and rack compatibility matrix For specific information about rail types and their functionalities. ● Rail adjustability range for...
Installation and Service Manual
Page 30
... dimensions • System weight • Processor specifications • PSU specifications • Supported operating systems • Cooling fan specifications • System battery specifications • Expansion card riser specifications • Memory specifications • Storage controller specifications • Drives • Ports and connectors specifications • Video specifications • Environmental specifications 30 Technical specifications 3 Technical specifications The technical and environmental specifications of your system are outlined in...
... dimensions • System weight • Processor specifications • PSU specifications • Supported operating systems • Cooling fan specifications • System battery specifications • Expansion card riser specifications • Memory specifications • Storage controller specifications • Drives • Ports and connectors specifications • Video specifications • Environmental specifications 30 Technical specifications 3 Technical specifications The technical and environmental specifications of your system are outlined in...
Installation and Service Manual
Page 31
... A server without drives and PSU installed Maximum weight (with all drives/SSDs) 36.1 kg (79.58 lbs) 25.1 kg (55.33 lbs) Technical specifications 31 Chassis dimensions Figure 28. PowerEdge R760 chassis dimensions Xa Xb Y 482.0 mm (18.97 inches) 434.0 mm (17.08 86.8 mm (3.41 inches) inches) Za 35.84 mm...
... A server without drives and PSU installed Maximum weight (with all drives/SSDs) 36.1 kg (79.58 lbs) 25.1 kg (55.33 lbs) Technical specifications 31 Chassis dimensions Figure 28. PowerEdge R760 chassis dimensions Xa Xb Y 482.0 mm (18.97 inches) 434.0 mm (17.08 86.8 mm (3.41 inches) inches) Za 35.84 mm...
Installation and Service Manual
Page 32
...of processors supported Up to two PSU specifications The PowerEdge R760 system supports up to ensure optimum power utilization, verify the system power consumption with AC 2400 W PSUs operates at Dell.com/calc. Table 12. PSU specifications PSU Class Heat dissipatio n (maximu...3.4 9.2-4.7 3.8 12-6.3 5.2 12-8 6.6 10 8.2 16-13.5 11.2 15.6 13.6 27 NOTE: Heat dissipation is degraded to 1400 W. 32 Technical specifications NOTE: When selecting or upgrading the system configuration, to two AC or DC power supply units (PSUs). NOTE: If a system with the Enterprise Infrastructure Planning...
...of processors supported Up to two PSU specifications The PowerEdge R760 system supports up to ensure optimum power utilization, verify the system power consumption with AC 2400 W PSUs operates at Dell.com/calc. Table 12. PSU specifications PSU Class Heat dissipatio n (maximu...3.4 9.2-4.7 3.8 12-6.3 5.2 12-8 6.6 10 8.2 16-13.5 11.2 15.6 13.6 27 NOTE: Heat dissipation is degraded to 1400 W. 32 Technical specifications NOTE: When selecting or upgrading the system configuration, to two AC or DC power supply units (PSUs). NOTE: If a system with the Enterprise Infrastructure Planning...
Installation and Service Manual
Page 33
... www.dell.com/ossupport. Figure 29. PSU power cords Table 13. NOTE: C13 power cord combined with C20 to C21 jumper power cord can be used to 1050 W. The PowerEdge R760 offers two types of cooling options: ● Air cooling ● Direct Liquid Cooling (DLC) (optional) Technical specifications 33 Cooling fan specifications Cooling options The PowerEdge R760...
... www.dell.com/ossupport. Figure 29. PSU power cords Table 13. NOTE: C13 power cord combined with C20 to C21 jumper power cord can be used to 1050 W. The PowerEdge R760 offers two types of cooling options: ● Air cooling ● Direct Liquid Cooling (DLC) (optional) Technical specifications 33 Cooling fan specifications Cooling options The PowerEdge R760...
Installation and Service Manual
Page 34
... lengths and two low profiles) on the system board. 34 Technical specifications System battery specifications The PowerEdge R760 system uses one CR 2032 3.0 V lithium coin cell battery. Cooling fan specifications The PowerEdge R760 system system supports up to six standard (STD), High performance Silver ...(HPR) grade , or High performance Gold (VHP) grade cooling fans. Cooling fan specifications Fan type Abbreviation Standard (STD) STD...
... lengths and two low profiles) on the system board. 34 Technical specifications System battery specifications The PowerEdge R760 system uses one CR 2032 3.0 V lithium coin cell battery. Cooling fan specifications The PowerEdge R760 system system supports up to six standard (STD), High performance Silver ...(HPR) grade , or High performance Gold (VHP) grade cooling fans. Cooling fan specifications Fan type Abbreviation Standard (STD) STD...
Installation and Service Manual
Page 35
... length x16 (Gen Slot 2 Full height - x16 - length length Full Full Slot 8 height Half height Half - - - - - - Technical specifications 35 Full length x8 5) (Dou ble widt x8 (Gen5) h x16 (Gen 5) - - x16 - length length Full Full Slot 7 height Half... R1R R2A R3A Full Full Slot 1 height Half height Full x8 - x8 (Gen5) x8 (Gen5 ) Memory specifications The PowerEdge R760 system supports the following memory specifications for optimized operation. height - GPU ) Low Low Slot 3 profile Half profile Half - - - - x16...
... length x16 (Gen Slot 2 Full height - x16 - length length Full Full Slot 8 height Half height Half - - - - - - Technical specifications 35 Full length x8 5) (Dou ble widt x8 (Gen5) h x16 (Gen 5) - - x16 - length length Full Full Slot 7 height Half... R1R R2A R3A Full Full Slot 1 height Half height Full x8 - x8 (Gen5) x8 (Gen5 ) Memory specifications The PowerEdge R760 system supports the following memory specifications for optimized operation. height - GPU ) Low Low Slot 3 profile Half profile Half - - - - x16...
Installation and Service Manual
Page 36
... SAS Host Bus Adapters (HBA) ● HBA355i Drives The PowerEdge R760 system supports: ● 12 x 3.5-inch hot-swappable SAS or SATA drives ● 8 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives ● 16 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives 36 Technical specifications NOTE: Memory DIMM slots are not supported in the... 32 GB 512 GB 64 GB 1 TB 128 GB 2 TB 256 GB 4 TB 512 GB 8 TB NOTE: DDR4 memories are not hot pluggable. Storage controller specifications The PowerEdge R760 system supports the following controller cards: Table 18. Table 16.
... SAS Host Bus Adapters (HBA) ● HBA355i Drives The PowerEdge R760 system supports: ● 12 x 3.5-inch hot-swappable SAS or SATA drives ● 8 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives ● 16 x 2.5-inch hot-swappable SAS, SATA, or NVMe drives 36 Technical specifications NOTE: Memory DIMM slots are not supported in the... 32 GB 512 GB 64 GB 1 TB 128 GB 2 TB 256 GB 4 TB 512 GB 8 TB NOTE: DDR4 memories are not hot pluggable. Storage controller specifications The PowerEdge R760 system supports the following controller cards: Table 18. Table 16.
Installation and Service Manual
Page 37
... For more information about how to be used as an iDRAC Direct or a management port. NIC port specifications The PowerEdge R760 system supports up to two Netwodk Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM)...> Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select This Product > Documentation > Manuals and Documents. Technical specifications 37 of ports Internal USB 3.0- compliant port) USB 3.0- PowerEdge R760 USB specifications Front Rear USB port type No. when x16 PCIe width...
... For more information about how to be used as an iDRAC Direct or a management port. NIC port specifications The PowerEdge R760 system supports up to two Netwodk Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM)...> Data Center Infrastructure > Storage Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Select This Product > Documentation > Manuals and Documents. Technical specifications 37 of ports Internal USB 3.0- compliant port) USB 3.0- PowerEdge R760 USB specifications Front Rear USB port type No. when x16 PCIe width...
Installation and Service Manual
Page 38
... continuous operations Temperature range for altitudes Table 22. Video specifications The PowerEdge R760 system supports integrated Matrox G200 graphics controller with the Documentation on www.dell.com/support/home. Table 21. Supported video resolution options Resolution Refresh rate (Hz) Color depth (bits) ... 1680 x 1050 60 8, 16, 32 1920 x 1080 60 8, 16, 32 1920 x 1200 60 8, 16, 32 Environmental specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with 16 MB of video frame buffer.
... continuous operations Temperature range for altitudes Table 22. Video specifications The PowerEdge R760 system supports integrated Matrox G200 graphics controller with the Documentation on www.dell.com/support/home. Table 21. Supported video resolution options Resolution Refresh rate (Hz) Color depth (bits) ... 1680 x 1050 60 8, 16, 32 1920 x 1080 60 8, 16, 32 1920 x 1200 60 8, 16, 32 Environmental specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with 16 MB of video frame buffer.
Installation and Service Manual
Page 39
Continuous Operation Specifications for ASHRAE A4 Temperature Specifications Allowable continuous operations Temperature range for altitudes Table 24.
Continuous Operation Specifications for ASHRAE A4 Temperature Specifications Allowable continuous operations Temperature range for altitudes Table 24.
Installation and Service Manual
Page 40
...Class G1 or that are anticipated to data center and non-data center environments. Table 28. Particulate contamination specifications Particulate contamination Specifications Air filtration Data center air filtration as an office or factory floor. Class 8 per ISO 1466-1 filtration... dust ● Residual dust present in environments such as defined by ISO Class 8 per year. Gaseous contamination specifications Gaseous contamination Specifications Copper coupon corrosion rate Conductive dust Air must have a deliquescent point less than 60% relative humidity NOTE: This...
...Class G1 or that are anticipated to data center and non-data center environments. Table 28. Particulate contamination specifications Particulate contamination Specifications Air filtration Data center air filtration as an office or factory floor. Class 8 per ISO 1466-1 filtration... dust ● Residual dust present in environments such as defined by ISO Class 8 per year. Gaseous contamination specifications Gaseous contamination Specifications Copper coupon corrosion rate Conductive dust Air must have a deliquescent point less than 60% relative humidity NOTE: This...
Installation and Service Manual
Page 41
...;F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) Technical specifications 41
...;F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) Technical specifications 41
Installation and Service Manual
Page 42
... ed d DLC d DLC d DLC (95°F) DLC DLC DLC DLC NOTE: ^The fan speed in the 3.5-inch chassis is 30°C (86°F). 42 Technical specifications
... ed d DLC d DLC d DLC (95°F) DLC DLC DLC DLC NOTE: ^The fan speed in the 3.5-inch chassis is 30°C (86°F). 42 Technical specifications
Installation and Service Manual
Page 43
Thermal restriction matrix for memory with rear fan DIMM Configu ration 2DP C/ Pow er STD fan (CPU TDP inch inch with with rear fan rear fan No rear drives No rear drives No rear drives 2.5inch rear drives with air cooled configuration (non-GPU) No 8 x 2.5Configuration backpl inch ane NVMe 16 x 2.5inch SAS 16 x 2.5inch NVMe 24 x 2.5-inch SAS 16 x 2.5inch SAS + 8 x 2.5inch NVMe 24 x 2.5inch NVMe 12 x 3.5-inch Rear storage No rear drives No rear drives No rear drives No rear drives No rear drives 2 x 2.5- 4 x 2.5- Table 33.
Thermal restriction matrix for memory with rear fan DIMM Configu ration 2DP C/ Pow er STD fan (CPU TDP inch inch with with rear fan rear fan No rear drives No rear drives No rear drives 2.5inch rear drives with air cooled configuration (non-GPU) No 8 x 2.5Configuration backpl inch ane NVMe 16 x 2.5inch SAS 16 x 2.5inch NVMe 24 x 2.5-inch SAS 16 x 2.5inch SAS + 8 x 2.5inch NVMe 24 x 2.5inch NVMe 12 x 3.5-inch Rear storage No rear drives No rear drives No rear drives No rear drives No rear drives 2 x 2.5- 4 x 2.5- Table 33.
Installation and Service Manual
Page 44
...°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 30°C (86°F) 30°C (86°F) Required DLC 44 Technical specifications Thermal restriction matrix for GPU configurations Configuration No backplane 8 x 2.5inch NVMe 8 x 2.5inch NVMe + 8 x 2.5inch SAS 16 x 2.5inch SAS 16 x 2.5inch NVMe 24 x 2.5inch SAS Rear...
...°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 30°C (86°F) 30°C (86°F) Required DLC 44 Technical specifications Thermal restriction matrix for GPU configurations Configuration No backplane 8 x 2.5inch NVMe 8 x 2.5inch NVMe + 8 x 2.5inch SAS 16 x 2.5inch SAS 16 x 2.5inch NVMe 24 x 2.5inch SAS Rear...