Product Manual
Page 5
DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch PoE System Configuration...65 PoE Port Configuration...66 Single IP Settings...68 SIM Settings...69 Topology...71 Tool Tips...73 Right-Click...74 Menu Bar ...... Settings...83 SMTP Service ...83 L2 Features ...85 VLANs...85 Static VLAN Entry...90 GVRP Settings ...92 VLAN Trunk Settings...94 QinQ...96 Trunking ...98 Link Aggregation ...99 LACP Port Settings...99 IGMP Snooping...101 Router Ports Settings...103 IGMP Authentication...105 Dynamic IP Multicast Learning ...107 ISM VLAN Settings...108...
DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch PoE System Configuration...65 PoE Port Configuration...66 Single IP Settings...68 SIM Settings...69 Topology...71 Tool Tips...73 Right-Click...74 Menu Bar ...... Settings...83 SMTP Service ...83 L2 Features ...85 VLANs...85 Static VLAN Entry...90 GVRP Settings ...92 VLAN Trunk Settings...94 QinQ...96 Trunking ...98 Link Aggregation ...99 LACP Port Settings...99 IGMP Snooping...101 Router Ports Settings...103 IGMP Authentication...105 Dynamic IP Multicast Learning ...107 ISM VLAN Settings...108...
Product Manual
Page 14
...) support Port Mirroring support MIB support for varying port counts. These Switches provide unsurpassed performance, fault tolerance, scalable flexibility, robust security, standard-based interoperability and impressive technology to the total group of the D-Link Switch family. The following manual describes the installation, maintenance, and configurations concerning the DES-3028, DES-3028P, DES3028G, DES-3052, and DES-3052P.
...) support Port Mirroring support MIB support for varying port counts. These Switches provide unsurpassed performance, fault tolerance, scalable flexibility, robust security, standard-based interoperability and impressive technology to the total group of the D-Link Switch family. The following manual describes the installation, maintenance, and configurations concerning the DES-3028, DES-3028P, DES3028G, DES-3052, and DES-3052P.
Product Manual
Page 15
DES-3028 DES-3028P DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch RFC1493 Bridge RFC2819 RMON RFC2665 Ether-like ...Priority Queues IEEE 802.3u 100BASE-TX compliant RS-232 DCE console port for Switch management Provides parallel LED display for both 10Mbps and 100Mbps connections. It only works with ... Full and half-duplex for port status such as link/act, speed, etc. IEEE 802.3 10BASE-T compliant High performance switching engine performs forwarding and filtering at half-duplex Support Broadcast...
DES-3028 DES-3028P DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch RFC1493 Bridge RFC2819 RMON RFC2665 Ether-like ...Priority Queues IEEE 802.3u 100BASE-TX compliant RS-232 DCE console port for Switch management Provides parallel LED display for both 10Mbps and 100Mbps connections. It only works with ... Full and half-duplex for port status such as link/act, speed, etc. IEEE 802.3 10BASE-T compliant High performance switching engine performs forwarding and filtering at half-duplex Support Broadcast...
Product Manual
Page 17
LED Indicators on DES-3028G Switch Figure 1- 4. LED Indicators on DES-3028 Switch Figure 1- 2. PoE 3052P) Green Green Status Solid Light Light off Solid Light Blinking Light off Link/Act/Speed Mode PoE Mode 3 DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch LED Indicators The Switch supports LED indicators for the DES-3028/28P/28G/52/52P Series switches along with an...
LED Indicators on DES-3028G Switch Figure 1- 4. LED Indicators on DES-3028 Switch Figure 1- 2. PoE 3052P) Green Green Status Solid Light Light off Solid Light Blinking Light off Link/Act/Speed Mode PoE Mode 3 DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch LED Indicators The Switch supports LED indicators for the DES-3028/28P/28G/52/52P Series switches along with an...
Product Manual
Page 18
... there is reception or Blinking Amber transmission (i.e. Blinking Green Act) of data occurring at the ports. Link/Act/Speed When there is a secure mode for DES-3028P/DES- When there is reception or Blinking Amber transmission (i.e. Activity- When there is a secure Solid Amber ... a error condition 3052P) Powered Device may receive Light off No link When there is a secure Solid Green 1000Mbps connection (or link) at the ports. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Link/Act/Speed LED Per 10/100 Mbps Port When there is ...
... there is reception or Blinking Amber transmission (i.e. Blinking Green Act) of data occurring at the ports. Link/Act/Speed When there is a secure mode for DES-3028P/DES- When there is reception or Blinking Amber transmission (i.e. Activity- When there is a secure Solid Amber ... a error condition 3052P) Powered Device may receive Light off No link When there is a secure Solid Green 1000Mbps connection (or link) at the ports. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Link/Act/Speed LED Per 10/100 Mbps Port When there is ...
Product Manual
Page 19
... the right One female DCE RS -232 DB-9 console port LEDs for Power, Console, PoE, Link/Act/Speed for each port Figure 1- 6. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Front-Panel Description DES-3028/DES-3028P Twenty-four 10/100Mbps BASE-T ports Two Combo 1000BASE-T/SFP ports located to the right...
... the right One female DCE RS -232 DB-9 console port LEDs for Power, Console, PoE, Link/Act/Speed for each port Figure 1- 6. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Front-Panel Description DES-3028/DES-3028P Twenty-four 10/100Mbps BASE-T ports Two Combo 1000BASE-T/SFP ports located to the right...
Product Manual
Page 22
...-optical transceiver cabling in the Switch. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Figure 1- 16. Figure 1- 17. Inserting the fiber-optic transceivers into the DES-3028/28P/28G/52/52P Switch 8 See the figure below for a gigabit link that may span great distances.... Installing the Mini-GBIC Module Installing the SFP ports The DES-3028/28P/28G/52/52P Switches are equipped with SFP (Small Form...
...-optical transceiver cabling in the Switch. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Figure 1- 16. Figure 1- 17. Inserting the fiber-optic transceivers into the DES-3028/28P/28G/52/52P Switch 8 See the figure below for a gigabit link that may span great distances.... Installing the Mini-GBIC Module Installing the SFP ports The DES-3028/28P/28G/52/52P Switches are equipped with SFP (Small Form...
Product Manual
Page 23
...Link Reseller for setting up the Switch. Install the Switch on CD Mounting kit (two brackets and screws) Four rubber feet with adhesive backing DCE RS-232 console cable If any item is proper heat dissipation from scratching other surfaces. 9 DES-3028 DES-3028P DES-3028G DES-3052 DES...-3052P Layer 2 Fast Ethernet Managed Switch Section 2 Installation Package Contents Before You Connect to the Network The site where you install...
...Link Reseller for setting up the Switch. Install the Switch on CD Mounting kit (two brackets and screws) Four rubber feet with adhesive backing DCE RS-232 console cable If any item is proper heat dissipation from scratching other surfaces. 9 DES-3028 DES-3028P DES-3028G DES-3052 DES...-3052P Layer 2 Fast Ethernet Managed Switch Section 2 Installation Package Contents Before You Connect to the Network The site where you install...
Product Manual
Page 26
... blinking LED indicates packet activity on that port. 12 DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Section 3 Connecting the Switch Switch to End Node Switch to Hub or Switch Connecting to Network Backbone or Server NOTE: All 10.../100/1000Mbps NWay Ethernet ports can be connected to an end node The Link/Act LEDs for each UTP port will light green or amber when the link...
... blinking LED indicates packet activity on that port. 12 DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Section 3 Connecting the Switch Switch to End Node Switch to Hub or Switch Connecting to Network Backbone or Server NOTE: All 10.../100/1000Mbps NWay Ethernet ports can be connected to an end node The Link/Act LEDs for each UTP port will light green or amber when the link...
Product Manual
Page 27
DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Switch to Hub or Switch These connections can be connected to the Switch via a twisted pair Category 5e UTP/STP cable. A switch supporting a fiber-optic uplink can be connected to the Switch's SFP ports via fiber-optic cabling. Figure 3- 2. Switch...hub or switch can be connected to the Switch via a twisted-pair Category 5 UTP/STP cable. A 1000BASE-T switch can be accomplished in a number of ways using a straight or crossover cable NOTICE: When the SFP transceiver acquires a link, the...
DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Switch to Hub or Switch These connections can be connected to the Switch via a twisted pair Category 5e UTP/STP cable. A switch supporting a fiber-optic uplink can be connected to the Switch's SFP ports via fiber-optic cabling. Figure 3- 2. Switch...hub or switch can be connected to the Switch via a twisted-pair Category 5 UTP/STP cable. A 1000BASE-T switch can be accomplished in a number of ways using a straight or crossover cable NOTICE: When the SFP transceiver acquires a link, the...
Product Manual
Page 29
...the command line interface. Upon the initial connection, there is configured to configure the Switch. 12. UserName: Figure 4- 1. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch 7. After you HyperTerminal window, clicking on Properties in and continue to match these...the available management functions. If you have completed your desired tasks. DES-3028G Fast Ethernet Switch Command Line Interface Firmware: Build 2.00.B26 Copyright(C) 2009 D-Link Corporation. The Switch will enter commands to use HyperTerminal with the logout command or ...
...the command line interface. Upon the initial connection, there is configured to configure the Switch. 12. UserName: Figure 4- 1. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch 7. After you HyperTerminal window, clicking on Properties in and continue to match these...the available management functions. If you have completed your desired tasks. DES-3028G Fast Ethernet Switch Command Line Interface Firmware: Build 2.00.B26 Copyright(C) 2009 D-Link Corporation. The Switch will enter commands to use HyperTerminal with the logout command or ...
Product Manual
Page 30
Leave the Username and Password fields blank. DES-3028G Fast Ethernet Switch Command Line Interface Firmware: Build 2.00.B26 Copyright(C) 2009 D-Link Corporation. All rights reserved. Command Prompt NOTE: The first user automatically gets Administrator level privileges.... users from accessing the Switch or changing its settings. Press Enter in the Switch to the Switch, you first connect to refresh the console screen. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch First Time Connecting to the Switch The Switch supports user-based security ...
Leave the Username and Password fields blank. DES-3028G Fast Ethernet Switch Command Line Interface Firmware: Build 2.00.B26 Copyright(C) 2009 D-Link Corporation. All rights reserved. Command Prompt NOTE: The first user automatically gets Administrator level privileges.... users from accessing the Switch or changing its settings. Press Enter in the Switch to the Switch, you first connect to refresh the console screen. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch First Time Connecting to the Switch The Switch supports user-based security ...
Product Manual
Page 37
Click the D-Link logo to go to display the hyperlinked window buttons and subfolders contained within them. Presents switch information based on the specified mode. Presents a graphical near real-time image of the front panel of configuration data...duplex mode, or flow control, depending on your selection and the entry of the Switch. Various areas of the graphic can be selected for performing management functions, including port configuration. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Area 2 Area 1 Area Area 1 Area 2 Area 3 Function Figure 5- ...
Click the D-Link logo to go to display the hyperlinked window buttons and subfolders contained within them. Presents switch information based on the specified mode. Presents a graphical near real-time image of the front panel of configuration data...duplex mode, or flow control, depending on your selection and the entry of the Switch. Various areas of the graphic can be selected for performing management functions, including port configuration. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Area 2 Area 1 Area Area 1 Area 2 Area 3 Function Figure 5- ...
Product Manual
Page 40
Device Information window 26 DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Device Information This window contains the main settings for easy access from the Device Information window. The Device Information window shows the Switch's MAC Address (assigned by the factory and ... status of functions on . Figure 6- 1. To return to obtain the Switch's MAC address for entry into another network device's address table, if necessary. Some functions are hyper-linked to their current global status. This information is helpful to keep track of...
Device Information window 26 DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Device Information This window contains the main settings for easy access from the Device Information window. The Device Information window shows the Switch's MAC Address (assigned by the factory and ... status of functions on . Figure 6- 1. To return to obtain the Switch's MAC address for entry into another network device's address table, if necessary. Some functions are hyper-linked to their current global status. This information is helpful to keep track of...
Product Manual
Page 41
.... The "well-known" TCP port for the Telnet protocol is Enabled by the Switch's 802.1X function; the default is 10 minutes. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch The fields that can be set to 9600, which the ports configured for 802....the load across the ports that make up the port trunk group is Disabled. Link Aggregation Algorithm The algorithm that the Switch uses to allow configuration of MLD Snooping on the Switch. This name will forward all multicast traffic to disable this by this manual). MAC...
.... The "well-known" TCP port for the Telnet protocol is Enabled by the Switch's 802.1X function; the default is 10 minutes. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch The fields that can be set to 9600, which the ports configured for 802....the load across the ports that make up the port trunk group is Disabled. Link Aggregation Algorithm The algorithm that the Switch uses to allow configuration of MLD Snooping on the Switch. This name will forward all multicast traffic to disable this by this manual). MAC...
Product Manual
Page 46
.... The master setting (1000M/Full_M) will also determine the master and slave relationship between 10 and 100 Mbps devices, in a link down menus to select the port or range of ports to configure two types of the two. The default is the one connection...uses loop timing, where the timing comes from a data stream received from the other side of a gigabit connection. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch The following parameters can handle, and then to use an automatic selection of gigabit connections; 1000M/Full_M and 1000M/Full_S...
.... The master setting (1000M/Full_M) will also determine the master and slave relationship between 10 and 100 Mbps devices, in a link down menus to select the port or range of ports to configure two types of the two. The default is the one connection...uses loop timing, where the timing comes from a data stream received from the other side of a gigabit connection. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch The following parameters can handle, and then to use an automatic selection of gigabit connections; 1000M/Full_M and 1000M/Full_S...
Product Manual
Page 47
DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Port Description The Switch supports a port description feature where the user may name various ports on the Switch. If configuring the Combo ports this window, click Administration > Port Configuration > Port Error Disabled. SFP ports should ...fiber ports). The Medium Type applies only to set the descriptions in the appropriate switch port number slot (C for copper ports and F for reasons such as STP loopback detection or link down menu to choose a port or range of ports to view the following ...
DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Port Description The Switch supports a port description feature where the user may name various ports on the Switch. If configuring the Combo ports this window, click Administration > Port Configuration > Port Error Disabled. SFP ports should ...fiber ports). The Medium Type applies only to set the descriptions in the appropriate switch port number slot (C for copper ports and F for reasons such as STP loopback detection or link down menu to choose a port or range of ports to view the following ...
Product Manual
Page 54
...password in the Confirm New Password. VID List This is the VLAN Name that identifies the VLAN the user wishes to the D-Link website and the White Paper entitled "Password Recovery Procedure", which will open the Administration folder and click on the Add button. ...Local Relay Operation. Click Apply to the User Account Table click the hyperlinked Show All User Account Entries. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch The following parameters may be configured or viewed. State Enable or Disable the DHCP/BOOTP Local Relay Settings...
...password in the Confirm New Password. VID List This is the VLAN Name that identifies the VLAN the user wishes to the D-Link website and the White Paper entitled "Password Recovery Procedure", which will open the Administration folder and click on the Add button. ...Local Relay Operation. Click Apply to the User Account Table click the hyperlinked Show All User Account Entries. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch The following parameters may be configured or viewed. State Enable or Disable the DHCP/BOOTP Local Relay Settings...
Product Manual
Page 56
... the position where the error has occurred. 42 Link Down When a particular port is in the Cable Diagnostics Information table below. Cable Diagnostic Table window The following window is used to test the cables connecting to the Switch. To view this window click, Administration > Cable... in link-up status it may have four pairs of cable that will detect the type of ports to be tested and click the Test Now button which will be diagnosed. GE ports have occurred. Figure 6- 14. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Cable...
... the position where the error has occurred. 42 Link Down When a particular port is in the Cable Diagnostics Information table below. Cable Diagnostic Table window The following window is used to test the cables connecting to the Switch. To view this window click, Administration > Cable... in link-up status it may have four pairs of cable that will detect the type of ports to be tested and click the Test Now button which will be diagnosed. GE ports have occurred. Figure 6- 14. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch Cable...
Product Manual
Page 60
Figure 6- 18. The default is 514. 6000-65535) Status Choose Enabled or Disabled to delete. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch 0 kernel messages 1 user-level messages 2 mail system 3 system daemons 4 security/authorization messages 5 messages generated internally by syslog line printer subsystem 7 network news ... entry to activate or deactivate. To return to the System Log Host window, click the Show All System Log Servers link. 46 Add/Edit window To set the System Log Server configuration, click Apply. System Log Host -
Figure 6- 18. The default is 514. 6000-65535) Status Choose Enabled or Disabled to delete. DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Managed Switch 0 kernel messages 1 user-level messages 2 mail system 3 system daemons 4 security/authorization messages 5 messages generated internally by syslog line printer subsystem 7 network news ... entry to activate or deactivate. To return to the System Log Host window, click the Show All System Log Servers link. 46 Add/Edit window To set the System Log Server configuration, click Apply. System Log Host -