Quick Start Guide
Page 1
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents • Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch • Rackmount Kit • Power Cord • This Quick Start Guide
Quick Start Guide Cisco Small Business Cisco Unmanaged Rackmount Switches Package Contents • Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch • Rackmount Kit • Power Cord • This Quick Start Guide
Quick Start Guide
Page 2
...000 bytes called jumbo frames. For additional information, see www.cisco.com/smb. or full-duplex) for choosing the Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch, a Cisco Small Business network communications device. all received packets are given ...priority over data traffic. Jumbo Frame Support SG 100-16, SG 100-24, and ...
...000 bytes called jumbo frames. For additional information, see www.cisco.com/smb. or full-duplex) for choosing the Cisco SF 100-16, SF 100-24, SF 102-24, SG 100-16, SG 100-24, or SG 102-24 Unmanaged Rackmount Switch, a Cisco Small Business network communications device. all received packets are given ...priority over data traffic. Jumbo Frame Support SG 100-16, SG 100-24, and ...
Quick Start Guide
Page 4
... opposite side of the switch with the supplied screws and secure the bracket tightly. WARNING Insecure mounting might damage the device or cause injury. Cisco is smooth, flat, dry, and sturdy. STEP 3 After the brackets are attached to the switch, use suitable screws to securely attach the...insecure wallmounting. STEP 1 Place the switch on a hard, flat surface with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 10/100/1000 24-Port Switch 193086 Wall Mounting A Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch can be wall-mounted. STEP 2 Attach a rack...
... opposite side of the switch with the supplied screws and secure the bracket tightly. WARNING Insecure mounting might damage the device or cause injury. Cisco is smooth, flat, dry, and sturdy. STEP 3 After the brackets are attached to the switch, use suitable screws to securely attach the...insecure wallmounting. STEP 1 Place the switch on a hard, flat surface with 24) miniGBIC1 miniGBIC2 Cisco Small Business SR2024 10/100/1000 24-Port Switch 193086 Wall Mounting A Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch can be wall-mounted. STEP 2 Attach a rack...
Quick Start Guide
Page 5
...inches (3 mm). SYSTEM Link/Act 1 2 34 56 7 8 9 10 11 12 / miniGBIC1 Gigabit Link/Act 13 14 15 16 17 18 19 20 21 22 23 24 / miniGBIC2 Gigabit 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with 24) ...miniGBIC1 miniGBIC2 Cisco Small Business SR2024 24-P or t 10/ 100/ 1000 Swit ch 193803 Cisco Unmanaged Rackmount Switches 4 STEP 4 Place the unmanaged rackmount switch ...
...inches (3 mm). SYSTEM Link/Act 1 2 34 56 7 8 9 10 11 12 / miniGBIC1 Gigabit Link/Act 13 14 15 16 17 18 19 20 21 22 23 24 / miniGBIC2 Gigabit 1 2 3 4 13 14 15 16 5 6 7 8 17 18 19 20 9 10 11 12 21 22 23 24 (Shared with 12) (Shared with 24) ...miniGBIC1 miniGBIC2 Cisco Small Business SR2024 24-P or t 10/ 100/ 1000 Swit ch 193803 Cisco Unmanaged Rackmount Switches 4 STEP 4 Place the unmanaged rackmount switch ...
Quick Start Guide
Page 7
...Rackmount Switches 6 When the MiniGBIC is active, the closest RJ-45 port is powered on the front panel of the switch. 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 LINK GIGABIT ACT RJ-45 Ethernet Ports -Use these ports to connect network ... the unmanaged rackmount switches that provide non-blocking, wire-speed switching for wired network communications. Front Panel Ports The ports and LEDs are compatible with Cisco miniGBIC modules MGBSX1, MGBLH1, MGBT1, MGBLX1, and MGBBX1, as well as computers, printers, and access points, to the miniGBIC interface traffic. Link/Act ...
...Rackmount Switches 6 When the MiniGBIC is active, the closest RJ-45 port is powered on the front panel of the switch. 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 LINK GIGABIT ACT RJ-45 Ethernet Ports -Use these ports to connect network ... the unmanaged rackmount switches that provide non-blocking, wire-speed switching for wired network communications. Front Panel Ports The ports and LEDs are compatible with Cisco miniGBIC modules MGBSX1, MGBLH1, MGBT1, MGBLX1, and MGBBX1, as well as computers, printers, and access points, to the miniGBIC interface traffic. Link/Act ...
Quick Start Guide
Page 8
... The Kensington lock is located on the back panel of the unmanaged rackmount switch. (Only the Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch has a lock.) 276580 276581 7 Cisco Unmanaged Rackmount Switches Gigabit LED (if present)-Lights and remains lit when another device is connected...
... The Kensington lock is located on the back panel of the unmanaged rackmount switch. (Only the Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch has a lock.) 276580 276581 7 Cisco Unmanaged Rackmount Switches Gigabit LED (if present)-Lights and remains lit when another device is connected...
Quick Start Guide
Page 9
... 100-24 24 RJ-45 10/100 ports SF 102-24 24 RJ-45 10/100 ports, 2 shared Gigabit RJ-45/miniGBIC ports SG 100-16 16 RJ-45 10/100/1000 ports SG 100-24 24 RJ-45 10/100/1000 ports SG 102-24 24 RJ-45 10/100/1000....4x44.45x170 440x44.45x202.5 279.4x44.45x170 Dimensions Inch 11x1.75x6.7 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 Cisco Unmanaged Rackmount Switches 8
... 100-24 24 RJ-45 10/100 ports SF 102-24 24 RJ-45 10/100 ports, 2 shared Gigabit RJ-45/miniGBIC ports SG 100-16 16 RJ-45 10/100/1000 ports SG 100-24 24 RJ-45 10/100/1000 ports SG 102-24 24 RJ-45 10/100/1000....4x44.45x170 440x44.45x202.5 279.4x44.45x170 Dimensions Inch 11x1.75x6.7 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 17.35x1.74x7.99 11x1.75x6.7 Cisco Unmanaged Rackmount Switches 8
Quick Start Guide
Page 10
Features Feature Standards Cabling Type Physical Security Power Certification Operating Temperature Storage Temperature Operating Humidity Storage Humidity Description IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, and 802.1p Category 5 or better Kensington security slot on a Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch 100V-240V~ 1A 50-60 Hz FCC Class A, CE 32 to 104ºF (0 to 40ºC) -4 to 158ºF (-20 to 70ºC) 10% to 90% Relative Humidity, noncondensing 10% to 90% Relative Humidity, noncondensing 9 Cisco Unmanaged Rackmount Switches
Features Feature Standards Cabling Type Physical Security Power Certification Operating Temperature Storage Temperature Operating Humidity Storage Humidity Description IEEE 802.3, 802.3u, 802.3x, 802.3ab, 802.3z, and 802.1p Category 5 or better Kensington security slot on a Cisco SF 100-16, SF 100-24, SG 100-16, or SG 102-24 Unmanaged Rackmount Switch 100V-240V~ 1A 50-60 Hz FCC Class A, CE 32 to 104ºF (0 to 40ºC) -4 to 158ºF (-20 to 70ºC) 10% to 90% Relative Humidity, noncondensing 10% to 90% Relative Humidity, noncondensing 9 Cisco Unmanaged Rackmount Switches
Hardware Installation Guide
Page 22
...3. Provides management communication with 12 full-duplex Gigabit Ethernet (GE) interfaces, each used to deliver up to 250 simultaneous streams and to 16 SCSI hard drives 12 full-duplex - Six Ethernet interfaces for content movement, an interface for ingest, and an interface for system management. ...Resets the device and runs the power-on a 400-GB drive), including storage of storage. Normally configured with the CDSM. 2. Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 1-6 OL-13478-03 Each drive contains 300 or 400 GB of information to ...
...3. Provides management communication with 12 full-duplex Gigabit Ethernet (GE) interfaces, each used to deliver up to 250 simultaneous streams and to 16 SCSI hard drives 12 full-duplex - Six Ethernet interfaces for content movement, an interface for ingest, and an interface for system management. ...Resets the device and runs the power-on a 400-GB drive), including storage of storage. Normally configured with the CDSM. 2. Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 1-6 OL-13478-03 Each drive contains 300 or 400 GB of information to ...
Hardware Installation Guide
Page 26
...7 No. A hard disk drive is in use. Figure 1-16 CDE400 Front Panel LEDs 12 270626 270627 No. Associated hard disk drive is in use . Port is powering on. Device is connected. Port is in use . 1-10 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide OL-13478...-03 Figure 1-16 shows the location of the CDE300 front panel LEDs, and describes their functions. Associated hard disk...
...7 No. A hard disk drive is in use. Figure 1-16 CDE400 Front Panel LEDs 12 270626 270627 No. Associated hard disk drive is in use . Port is powering on. Device is connected. Port is in use . 1-10 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide OL-13478...-03 Figure 1-16 shows the location of the CDE300 front panel LEDs, and describes their functions. Associated hard disk...
Hardware Installation Guide
Page 39
... in it must provide additional, proper grounding for short-circuit (overcurrent) protection. Warning This product relies on a branch circuit with articles 110-16, 110-17, and 110-18 of a centralized DC power system may be used as a disconnect device when easily accessible and should be ...Common Bonding Network (CBN) per feed pair. The overall current rating of continuous power per cord feed. Statement 1002 OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 2-9 The DC source must provide additional, proper grounding for the wires and ...
... in it must provide additional, proper grounding for short-circuit (overcurrent) protection. Warning This product relies on a branch circuit with articles 110-16, 110-17, and 110-18 of a centralized DC power system may be used as a disconnect device when easily accessible and should be ...Common Bonding Network (CBN) per feed pair. The overall current rating of continuous power per cord feed. Statement 1002 OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 2-9 The DC source must provide additional, proper grounding for the wires and ...
Hardware Installation Guide
Page 42
...Antistatic mat • Properly grounded ESD-preventive device • 1/4-inch flat-blade screwdriver • 3/16-inch flat-blade screwdriver • Number 2 Phillips screwdriver Unpacking the Box Each Cisco CDE is securely packaged in the CDEs. To unpack the shipping container, follow these boxes. Carefully ..., you need the following tools to link multiple servers together within a larger network. Tools and Parts Required You need to Cisco. Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 3-2 OL-13478-03 The cards and power supplies ship installed in ...
...Antistatic mat • Properly grounded ESD-preventive device • 1/4-inch flat-blade screwdriver • 3/16-inch flat-blade screwdriver • Number 2 Phillips screwdriver Unpacking the Box Each Cisco CDE is securely packaged in the CDEs. To unpack the shipping container, follow these boxes. Carefully ..., you need the following tools to link multiple servers together within a larger network. Tools and Parts Required You need to Cisco. Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 3-2 OL-13478-03 The cards and power supplies ship installed in ...
Hardware Installation Guide
Page 49
...4 disk drives (see Figure 3-6), the CDE200 contains 12 disk drives (see Figure 3-7), the CDE300 contains 16 disk drives (see Figure 3-8), and the CDE400 contains 24 disk drives (see the Cisco Internet Streamer CDS 2.0-2.1 Software Configuration Guide. If the CDE is recommended Can be 100/1000 Must be... drives on the CDE100 are monitored using the CDEs. Figure 3-6 CDE100 Disk Drive Locations sda sdb sdc sdd 211859 OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 3-9 A minimum of the following: Interface ISV ingest ISV management ISV stream CDSM...
...4 disk drives (see Figure 3-6), the CDE200 contains 12 disk drives (see Figure 3-7), the CDE300 contains 16 disk drives (see Figure 3-8), and the CDE400 contains 24 disk drives (see the Cisco Internet Streamer CDS 2.0-2.1 Software Configuration Guide. If the CDE is recommended Can be 100/1000 Must be... drives on the CDE100 are monitored using the CDEs. Figure 3-6 CDE100 Disk Drive Locations sda sdb sdc sdd 211859 OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 3-9 A minimum of the following: Interface ISV ingest ISV management ISV stream CDSM...
Hardware Installation Guide
Page 55
... the same as instructed at the bottom of the BIOS screen. Figure 4-1 Main Menu Tip If you are viewing the initial BIOS screen through Step 16 are required only for the initial installation. The Boot Settings menu appears (see Figure 4-1). Step 4 To enter the BIOS Setup menu, press Delete ... changed for the CDE100: Step 1 Step 2 Step 3 Power on the CDE100. Step 5 From the Main menu, choose Boot and press Enter. OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 4-3 Insert the CD with the CDS image into the internal CD-ROM drive. The BIOS...
... the same as instructed at the bottom of the BIOS screen. Figure 4-1 Main Menu Tip If you are viewing the initial BIOS screen through Step 16 are required only for the initial installation. The Boot Settings menu appears (see Figure 4-1). Step 4 To enter the BIOS Setup menu, press Delete ... changed for the CDE100: Step 1 Step 2 Step 3 Power on the CDE100. Step 5 From the Main menu, choose Boot and press Enter. OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 4-3 Insert the CD with the CDS image into the internal CD-ROM drive. The BIOS...
Hardware Installation Guide
Page 60
...the conclusion of the CDE100. The system boots from cdrom 6. Install flash image from network 5. Force manufacturing flash Choice [0]: Step 16 Confirm that the BIOS detected the flash device. Confirm that the FLASHDEV: line near the top of a new software image onto ...flash image from the image on page 4-1 for approximately five minutes. The CD boot menu is displayed at the following URL: www.cisco.com/techsupport Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 4-8 OL-13478-03 b. Once the CD starts booting, it displays a ...
...the conclusion of the CDE100. The system boots from cdrom 6. Install flash image from network 5. Force manufacturing flash Choice [0]: Step 16 Confirm that the BIOS detected the flash device. Confirm that the FLASHDEV: line near the top of a new software image onto ...flash image from the image on page 4-1 for approximately five minutes. The CD boot menu is displayed at the following URL: www.cisco.com/techsupport Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 4-8 OL-13478-03 b. Once the CD starts booting, it displays a ...
Hardware Installation Guide
Page 64
...: option to On-board COM A. Sometimes the USB CD-ROM drive is in the above Hard Drive element list. Figure 4-16 Console Redirection Screen Step 12 a. Press Yes when prompted (see Figure 4-16). a. Running the BIOS Setup Utility Chapter 4 Installing the Internet Streamer CDS Software and Initially Configuring a CDE Step 11 Use... are finished, navigate to confirm and reboot the system. Press the Reset button (not the Power button) and try a different USB CD-ROM drive. 4-12 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide OL-13478-03
...: option to On-board COM A. Sometimes the USB CD-ROM drive is in the above Hard Drive element list. Figure 4-16 Console Redirection Screen Step 12 a. Press Yes when prompted (see Figure 4-16). a. Running the BIOS Setup Utility Chapter 4 Installing the Internet Streamer CDS Software and Initially Configuring a CDE Step 11 Use... are finished, navigate to confirm and reboot the system. Press the Reset button (not the Power button) and try a different USB CD-ROM drive. 4-12 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide OL-13478-03
Hardware Installation Guide
Page 67
... System Manager) (y/n) [y]:y Please choose an interface to configure from the following steps to verify that the CDSM is reachable. OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 4-15 Note Once the IP default gateway has been set, we recommend you just configured...[SE]: SE Is this interface: 255.255.255.244 Please enter the default gateway: 10.0.0.0 Please enter the domain name server ip: 172.16.0.0 Please enter the domain name: spcdn.com Please enter the hostname: CDStr1 Please enter CDSM (Content Delivery System Manager) IP or Host name: ...
... System Manager) (y/n) [y]:y Please choose an interface to configure from the following steps to verify that the CDSM is reachable. OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide 4-15 Note Once the IP default gateway has been set, we recommend you just configured...[SE]: SE Is this interface: 255.255.255.244 Please enter the default gateway: 10.0.0.0 Please enter the domain name server ip: 172.16.0.0 Please enter the domain name: spcdn.com Please enter the hostname: CDStr1 Please enter CDSM (Content Delivery System Manager) IP or Host name: ...
Hardware Installation Guide
Page 68
The CDSM Main menu appears (see Figure 4-19). Figure 4-19 CDSM Main Menu 4-16 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide OL-13478-03 Verifying the CDSM Chapter 4 Installing the Internet Streamer CDS Software and Initially Configuring a CDE Figure 4-18 CDSM Login Page Step 2 Enter admin as the username and default as the password and press Login.
The CDSM Main menu appears (see Figure 4-19). Figure 4-19 CDSM Main Menu 4-16 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide OL-13478-03 Verifying the CDSM Chapter 4 Installing the Internet Streamer CDS Software and Initially Configuring a CDE Figure 4-18 CDSM Login Page Step 2 Enter admin as the username and default as the password and press Login.
Hardware Installation Guide
Page 75
... Power Power rating Humidity Operating temperature Altitude Dimensions (H x W x D) Weight (fully configured) Approvals: Safety Approvals: EMC 3 1.15-TB SCSI (16x 73-GB SCSI disks) 16 Gigabytes DRAM Copper: Twelve 10/100/1000BASE-T; One serial port for console None None 100-240 VAC or -48 VDC; Redundant power supplies included 950...17.25 x 27.50 in . (17.8 x 43.8 x 67.3 cm) 150 lb (68.0 kg) UL 1950, 3rd edition FCC Part 15 Class A (USA) OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide A-3 One serial port for console None None 100-240 VAC or -48 VDC;
... Power Power rating Humidity Operating temperature Altitude Dimensions (H x W x D) Weight (fully configured) Approvals: Safety Approvals: EMC 3 1.15-TB SCSI (16x 73-GB SCSI disks) 16 Gigabytes DRAM Copper: Twelve 10/100/1000BASE-T; One serial port for console None None 100-240 VAC or -48 VDC; Redundant power supplies included 950...17.25 x 27.50 in . (17.8 x 43.8 x 67.3 cm) 150 lb (68.0 kg) UL 1950, 3rd edition FCC Part 15 Class A (USA) OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide A-3 One serial port for console None None 100-240 VAC or -48 VDC;
Hardware Installation Guide
Page 85
Pre-encryption and Network PVR is fully supported 16 Gigabytes RAM Two Dual Xeon @ 3.2 GHz (or above ) Protocols IP, SNMP, FTP, Gigabit Ethernet, SSH, ...90 × 44.45 × 69.80 cm) Weight Chassis fully configured (all slots filled): 125 lb (56.7 kg) 16 SCSI 73-GB hard drives 1 Gigabit Ethernet interface 12 Gigabit Ethernet interfaces for hot-swapping. The power supplies for the CDE200 ISV server...and Advanced Codec Memory 8 Gigabytes RAM Processor Two Dual Xeon @ 3.6 GHz (or above ) OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide C-3
Pre-encryption and Network PVR is fully supported 16 Gigabytes RAM Two Dual Xeon @ 3.2 GHz (or above ) Protocols IP, SNMP, FTP, Gigabit Ethernet, SSH, ...90 × 44.45 × 69.80 cm) Weight Chassis fully configured (all slots filled): 125 lb (56.7 kg) 16 SCSI 73-GB hard drives 1 Gigabit Ethernet interface 12 Gigabit Ethernet interfaces for hot-swapping. The power supplies for the CDE200 ISV server...and Advanced Codec Memory 8 Gigabytes RAM Processor Two Dual Xeon @ 3.6 GHz (or above ) OL-13478-03 Cisco Content Delivery Engine 100/200/300/400 Hardware Installation Guide C-3