Question posted by danghuunghia2002 on September 13th, 2011

Chassis Codes B2600 For Run

B2600 RUNNING, BUT NOT LOGIN. MUST STOP AND START AGAIN AND I CAN LOGIN ON. INDICATE RUN F1AF ON THE LCD OF THE CPU

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related HP b2600 Manual Pages

hp workstation b2600 - technical reference (E0501) - Page 7

... 176 Connecting Wires 176 Grounding Your Workstation 176 Location for Your DC Source and Workstation(s 176 Removing the DC Power Supply 177 Replacing the DC Power Supply 180 7 Accessories and Replacement Parts HP B2600 Accessories 170 B2600 Supported Accessories 170 Parts and Part Numbers 171 E. HP B2600 Chassis Codes Chassis Codes 146 D. Contents Altitude 142 DC Magnetic...
hp workstation b2600 - technical reference (E0501) - Page 31

...'s pim, pdt, and ChassisCodes commands to system FRUs. All codes are the key to debugging selftest errors. If a failure is running Selftest Failures Chassis codes are listed in the system LCD. Troubleshooting Identifying LCD-Indicated Conditions Identifying LCD-Indicated Conditions This workstation uses a 2-line LCD, with up to 16 characters The 3-character operating status can...
hp workstation b2600 - technical reference (E0501) - Page 145

C HP B2600 Chassis Codes This appendix lists the LCD chassis codes for the HP B2600 workstation. 145
hp workstation b2600 - technical reference (E0501) - Page 146

... unexpected non-access DTLB miss or data page fault. 146 Appendix C CPU n detected an unexpected privileged register trap. CPU n detected an unexpected illegal instruction trap. CPU n detected an unexpected overflow trap. HP B2600 Chassis Codes Chassis Codes Chassis Codes Table C-1.lists all of the chassis codes for B2600 Workstations Ostat FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT...
hp workstation b2600 - technical reference (E0501) - Page 147

... an unexpected taken-branch trap. perf mon intrrpt CPU n detected an unexpected performance monitor interrupt. CPUn alu test CPU n is starting its bit operation instruction self-test. CPUn bit opers CPU n is starting its arithmetic and logical unit self-test. HP B2600 Chassis Codes Chassis Codes Table C-1. Chassis Codes for B2600 Workstations Ostat FLT FLT FLT FLT FLT FLT FLT...
hp workstation b2600 - technical reference (E0501) - Page 148

... self-test. CPUn itimer test CPU n is starting its TLB register self-test. 148 Appendix C CPUn start est CPU n is starting its floating-point bypassing self-test. CPUn fpu bypass CPU n is starting its early (pre-memory) self-tests. CPUn bypass test CPU n is starting its external interrupt self-test. Chassis Codes for B2600 Workstations Ostat TST TST TST TST TST...
hp workstation b2600 - technical reference (E0501) - Page 149

... cache tag self-test. monarchn selftst Monarch CPU n failed self-test. CPUn icache tag CPU n is starting its TLB translation self-test. CPUn icache par CPU n is starting its instruction cache RAM self-test. CPUn dcache RAM CPU n is testing the system status word. Appendix C 149 HP B2600 Chassis Codes Chassis Codes Table C-1. CPUn halt boot Bootstrap failure--machine...
hp workstation b2600 - technical reference (E0501) - Page 150

... bad The scratch RAM test passed. deflting EEPROM2 Monarch CPU n is clearing the EEPROM. CPUn dcache ECC CPU n is starting its data cache tag self-test. scratch RAM ok The scratch RAM test failed. EEPROM wrt limit CPU n detected a fatal error writing the EEPROM. Chassis Codes for B2600 Workstations Ostat TST TST FLT TST FLT INI TST INI...
hp workstation b2600 - technical reference (E0501) - Page 151

... debugger for B2600 Workstations Ostat INI FLT WRN TST WRN FLT TST WRN FLT INI TST INI FLT TST INI FLT FLT FLT FLT TST Code FRU 3n07 3n09... HP B2600 Chassis Codes Chassis Codes Table C-1. Chassis Codes for s more seconds. bad sys mde byte CPU n detected an unsupported system mode. check defaults CPU n is starting its late (with the real-time clock. init EEPROM err CPU n ...
hp workstation b2600 - technical reference (E0501) - Page 152

... re-executing its remote diagnose register self-test. CPUn exit lst CPU n finished its multi-media instructions self-test. CPUn lst dg regs CPU n is re-executing its branch instruction self-test. Chassis Codes for B2600 Workstations Ostat WRN TST TST TST TST TST TST TST TST TST TST TST TST TST TST TST TST...
hp workstation b2600 - technical reference (E0501) - Page 153

... bus timeout CPU n timed out before receiving requested data. start DIMM scan Start looking for B2600 Workstations Ostat TST...CPU sync failure CPU n's synchronizer detected a rule violation on the system bus (Runway). Chassis Codes for installed DIMMs. init mem tables Initialize memory data structures. skip mem pair ck Bypass memory DIMM set check. HP B2600 Chassis Codes Chassis Codes...
hp workstation b2600 - technical reference (E0501) - Page 154

...x% finished. skip mem reg tst Bypass the memory controller register test. strt DIMM detect Start the Serial Presence Detection (SPD) to use at own risk). 154 Appendix C mem err reg... detected an error in slot s as initial memory module. HP B2600 Chassis Codes Chassis Codes Table C-1. Chassis Codes for B2600 Workstations Ostat TST TST FLT TST INI INI TST WRN FLT FLT FLT FLT FLT ...
hp workstation b2600 - technical reference (E0501) - Page 155

...B2600 Workstations Ostat FLT FLT INI INI INI INI INI FLT FLT FLT INI TST WRN INI INI INI WRN INI FLT Code...the proper order. PDT is DIMM s inst? mem config start Starting main memory configuration. use confg change Memory physical...DIMM s and has deallocated it. Use stored configuration data. Chassis Codes for memory configuration change . DIMM will not be in matched ...
hp workstation b2600 - technical reference (E0501) - Page 156

... memory error logs. repeat dest test Re-execute destructive test for B2600 Workstations Ostat FLT FLT INI TST TST INI WRN FLT TST WRN TST TST...;rst try. start mem init Starting memory initialization. (Initialize to zero to continue. ECC wrt/read err Writing and reading back good data caused memory ECC error. 156 Appendix C HP B2600 Chassis Codes Chassis Codes Table C-1.
hp workstation b2600 - technical reference (E0501) - Page 157

... Uncorrectable ECC error detected in DIMM s. Replace DIMM s Correctable ECC error detected in DIMM s. Appendix C 157 Chassis Codes for B2600 Workstations Ostat FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT... progress word is bad and needs replacing. DIMM s corr err DIMM s is invalid. HP B2600 Chassis Codes Chassis Codes Table C-1.
hp workstation b2600 - technical reference (E0501) - Page 158

...IODC entry_init for B2600 Workstations Ostat FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT WRN WRN WRN Code FRU 7845 SYS ...detected a correctable memory error in DIMM s. PDT write error Error adding the entry to happen. HP B2600 Chassis Codes Chassis Codes Table C-1. mem err overflow Multiple memory errors detected. SBE&MBE DIMM s Destructive memory test detected ...
hp workstation b2600 - technical reference (E0501) - Page 159

...early R2PCI init Initializing Rope-to-PCI bridge 0 for early RS-232 output. PCI BusWlk start Starting PCI bus and device discovery. Roper config err Rope r configuration failed. R2PCI init.... boot IO error Error detected during boot device I /O for boot device. Chassis Codes for B2600 Workstations Ostat WRN WRN WRN WRN INI INI INI INI INI FLT WRN FLT INI...
hp workstation b2600 - technical reference (E0501) - Page 160

... drive configuration failed. PCI BIST test Running PCI Built-In Self-Test PCI BIST error PCI...64257;guration failed. no console found Search for B2600 Workstations Ostat WRN TST WRN WRN WRN WRN WRN WRN WRN...s Initializing PCI device in slot s as console display. HP B2600 Chassis Codes Chassis Codes Table C-1. init unknown dev Initializing unknown device as console display....
hp workstation b2600 - technical reference (E0501) - Page 161

Chassis Codes for B2600 Workstations Ostat WRN INI INI INI WRN INI WRN INI WRN INI WRN FLT WRN WRN FLT WRN WRN INI INI INI Code FRU 9C51 SYS BD 9C52 9160 SYS ...CPUm is checking whether the slaves are slaves.) monarchm test CPU m finished the monarch-only tests and system initialization. mnrch slv chck The monarch CPU is monarch CPU m was chosen as a console device. consol is SER_2...
hp workstation b2600 - technical reference (E0501) - Page 168

... Fan Modules" in Chapter 3. To determine the values for the monarch CPU to configure the system bus. CPUn early rend Slave CPU n entering the early rendezvous, waiting for n, see the section "Removing Fan Modules" in Chapter 3. 168 Appendix C fan n: failure! HP B2600 Chassis Codes Chassis Codes Table C-1. set dom1 fan spd Firmware is running too slowly.

Similar Questions

My Hp 2600 Workstation Shutdown Suddenly
i have a unix hp 2600 workstation shutdown suddenly at step of booting without any eeror message on ...
(Posted by esammahmoud283 4 years ago)
B2600 Product Dependent Code
I would like to install 4 x 1GB Dimms in my workstation. However the Dimms are not accepted. I have...
(Posted by mvdkroef 12 years ago)
Run F1af ?
(Posted by danghuunghia2002 12 years ago)
Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP b2600 - Workstation manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.