Get support for HP LH4r - NetServer - 256 MB RAM

HP LH4r Support Question

HP LH4r Support Question

Find answers below for this question about HP LH4r - NetServer - 256 MB RAM.
Need a HP LH4r manual? We have 353 online manuals for this item!
Question posted by Anonymous-157672 on March 4th, 2016

All 4 Hdd Showing Green Led But During Post Its Showing That Logical Drives (1)

I'm having Netserver LH4r with 4 9 gb SCSI hdd. All HDD leds are glowing green even though there it is showing that logical drive 1 failure!!!

Current Answers

Answer #1: Posted by TommyKervz on March 5th, 2016 5:37 AM
This answer was accepted by the poster of the original question.
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,813
1,100
points


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related HP LH4r Manual Pages

hp lp 1000r and ds2100 config guide — for Microsoft Windows 2000 A.S. Clusters PDF, 252K, 11/15/2001 - Page 2

... Assistant SCSI ID Channels RAID levels Logical disks ...drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP. LP1KR2K2M21 Server Configuration Parameter RAM Number of channel 1 can cause cluster failure...drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification 256 MB, minimum.
HP Netserver LC 2000 Frequently Asked Questions - Page 2

... Indicator LED This green LED indicator remains steady on the front panel of the fans may be turning too slowly. The NetServer LC 2000 supports Intel Pentium III 533 MHz, P III 600 MHz, P III 667 MHz and PIII 733 MHz processors. q Hard Disk Activity LED This yellow LED indicator flashes during SCSI or IDE disk drive activity. What...
HP Netserver LC 2000 Installation Guide - Page 18

..., then this button only turns power On or Off. Power On/Off/ Sleep LED This LED glows steady green when power is on and off . This includes keyboard lock, power button lock, and video blanking. Keyboard Lock LED This LED glows solid green when the HP NetServer's keyboard is locked, and is under ACPI control, this chapter. Table 2-1. RESET...
HP Netserver LC 2000 RS/12FC /Windows 2000 Advanced Server Cluster Configuration Guide - Page 2

...: HP NetServer LC 2000 733 MHz 2 4.06.20 PV or later Any size 256 MB minimum. Local storage P3 - Client LAN P5 - Shared Storage Storage Local Controller Driver Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids Use embedded SCSI as the boot controller. HP D8602A 1 Hhba.sys 2.06 P5 0,1, 3, 5 Not more than eight physical drives per logical array...
HP Netserver LC II Installation Roadmap - Page 5

... terminated, either by a terminator on the locking bar (shown below ) with SCSI address 0, 1, or 3, change the hot swap SCSI addresses, move the switches on the drive to the far right shows typical jumper settings for the recommended SCSI addresses. Switches on the back of the HP NetServer) into the hot swap tray in the optional HP...
HP Netserver LH 3 Installation Roadmap - Page 5

... this as a removable hard disk or a tape backup drive. your model may result due to addresses. See "Non-Hot-Swap SCSI Addressing," below shows the different combinations of the cage. Inserting a Hot-Swap Disk Drive Module 1. CAUTION Do not operate this NetServer. Hot-Swap Module Configurations and SCSI Addresses Both half-height (1.6-inch) and low-profile...
HP Netserver LH 3000 Installation Guide - Page 30

... above left of the Chassis PCI Attention LEDs If a hot-plug board needs attention, its LED glows amber. 1 2 3 Slot 5 needs 4 attention 5 6 7 8 Figure 2-6. Amber Attention LED When an amber PCI LED appears, you must remove the cover to see Chapter 3, "Opening and Closing the HP NetServer"). Chapter 2 Controls, Ports, and Indicators LEDs at the Rear of each hot...
HP Netserver LH 3000 Rack Cabling Guide - Page 48

...Site. For a full list of the Recommended 208 VAC Configuration Figure 3-6 shows a UPS connected to the PDU with an IEC 320 C-19 plug....LH 3000r Table 3-2. 208 VAC Components Component1 Model 208 VAC PDU HP NetServer LH 3000r E7671A or E7672A D8230A, 533 MHz, 512 MB D8238A, 600 MHz, 256 MB D8246B, 667 MHz, 256 MB Power (VA) N/A 516 Power (W) N/A 506 Current (A)2 max 16 2.5 HP NetServer...
HP Netserver LH 3000 Rack Cabling Guide - Page 51

...Current Component1 200/240 VAC PDU HP NetServer LH 3000r Model E7671A or E7672A D8230A, 533 MHz, 512 MB D8238A, 600 MHz, 256 MB D8246B, 667 MHz, 256 MB Power (VA) N/A 514 Power (W) N/A Current (A)2 max 16 504 2.3 HP NetServer Rack Storage/12 is D5989A 518 507...For a full list of the Recommended 230/240 VAC Configuration Figure 3-7 shows a UPS connected to the PDU via a C-19 plug.
HP Netserver LH 3000/3000r to LH 6000/6000r Upgrade Guide - Page 38

..., its LED glows steady green. 3. Run the HP DiagTools Utility HP DiagTools is an offline diagnostic program that all hot-swap drives will restart. Start the Setup utility by following the onscreen instructions that all hot-swap drives will be controlled by the embedded SCSI controllers on each power supply. Press F9 to the HP NetServer. 2. c. Select...
HP Netserver LH 3r Installation Roadmap - Page 5

... the drive module by pressing in the hot-swap mass-storage cage. The figure below shows the ...drive spin down completely before removing it (about 1 minute). 2. Press in consecutive locations only, beginning with the SCSI address. SCSI addresses listed here are terminated. Refer to the SE connector device for SCSI B channel addresses. Devices connected to the HP NetServer LH 3/LH...
HP Netserver LH 4 Installation Road Map - Page 5

...-swap trays available to the right is terminated. JUMPERS A0 A1 A2 A3 Jumper Settings The figure to accommodate drives of hot-swap devices possible. Use this NetServer -- See "Non-Hot-Swap SCSI Addressing," below shows the different combinations of different form factors. Otherwise, damage to the Low-Profile Disk Module or Filler Panel...
HP Netserver LH 4r Installation Road Map - Page 5

... Storage Devices This HP NetServer supports both hot-swap SCSI devices, Removing a Hot-Swap Disk Drive Module installed in the hot-swap mass storage cage, and non-hot swap SCSI devices, installed in the non-hot-swap shelves (shelves 3 and 4). Let the drive spin down completely before removing it (about 1 minute). below shows the possible combinations...
HP Netserver LPr Quick Service Guide - Page 3

...the LPr's embedded SCSI bus. HP NetServer LPr System Information Front Panel Controls CD-ROM Drive Drive Activity LED Reset Switch Power ON/OFF LED Power On/Off Switch Drive Error LED Power ON/OFF Switch Drive Activity Drive Error LED LED Hot Swap Drive Shelf SCSI ID #0 Hot Swap Drive Shelf SCSI ID #1 Fan Failure LED Over-temperature LED Floppy Disk Drive Power ON/OFF LED Reset Switch...
HP Netserver LXr 8000 Installation Guide - Page 9

... follow the setup steps in what order. If anything is especially important if you plan to set up the entire rack system. The Road Map shows how to the HP NetServer. 2. This is missing or damaged, call your HP NetServer. Failure to observe this warning could result in a safe place. 1 Setting Up the HP...
HP Netserver LXr 8000 Memory Upgrade Guide - Page 15

Figure 2-2. A memory board has 16 DIMM sockets and accepts 64 MB or 256 MB buffered EDO DIMMs (50 ns). Each board has a maximum capacity of 4 GB when fully populated with 256 MB DIMMs. The minimum memory configuration is four 64 MB DIMMs on the board. Memory Board and DIMM 9 Figure 2-2 shows a memory board and a DIMM fitting into a slot on...
HP Netserver LXr 8000 Memory Upgrade Guide - Page 15

A memory board has 16 DIMM sockets and accepts 64 MB or 256 MB buffered EDO DIMMs (50 ns). Each board has a maximum capacity of 4 GB when fully populated with 256 MB DIMMs. The minimum memory configuration is four 64 MB DIMMs on the board. Figure 2-2. Figure 2-2 shows a memory board and a DIMM fitting into a slot on the main memory board...
HP Netserver Remote Administrator Guide - Page 86

... failed 21213 NetRAID: Logical drive reconstruction started 21214 NetRAID: Logical drive reconstruction completed 21215 NetRAID: Logical drive reconstruction failed 21201 NetRAID: Configuration updated 21216 NetRAID: Physical drive predictive failure event occurred 21217 NetRAID: Physical drive predictive failure event occurred 21218 NetRAID: Abnormal end to SCSI operation 21219 NetRAID...
HP Netserver Service Handbook, Volume 2 - Mid - Page 138

... fan problem. Drive Active LED LED goes on (green) to indicate access over -temperature indicator is supporting transfers at 20 mbps. 130 This includes access to indicate that the LPr network adapter is flashing red or yellow, you may perform a graceful shutdown and then power down the system. Drive Error LED Over-Temperature LED Fan Failure LED LED flashes red...
Using Ultra SCSI in your HP Netserver - Page 1

... an easy-to communicate in HP NetServer LH, LH+, LH Pro, LS, LXe, LX, and Storage System/6. G.00.00 LH Plus, LH Pro HP Storage System/6 LC, LH, LS, E Series Ultra SCSI ready? The reason for data transfer rates of Ultra-SCSI in your HP NetServer Starting October 1996, HP began shipping Ultra SCSI capable disk drives. They will automatically try to...

Similar Questions

What Is The Led Indication Means?
LED indiacation on server RX2620.?
(Posted by ynmistry 8 years ago)
Logical Drive State: Background Parity Initialization Is Currently Queued Or In
progress on this logical drive. if background parity initialization is queued, it will start when i/...
(Posted by Lemar 9 years ago)
Hp Pavillion A 120
My computer takes ages to boot up and to do anyting: HDD 40gb, 256 Mb Ram, 2.56Ghz Pentium 4
(Posted by francoguelfi2 9 years ago)
Compaq Presario 7500series Monitor Mv540 Is Blank Even The Pc Light Turns Green
my PC screen is still black/ blank even my monitor lights turns from amber to green .It is a Pentium...
(Posted by pratt 12 years ago)
Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP LH4r - NetServer - 256 MB RAM manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.