HP DL385 - ProLiant - G5 Support and Manuals

Get Help and Manuals for this Hewlett-Packard item

View All Support Options Below
Free HP DL385 manuals!
Problems with HP DL385?

Ask a Question

Most Recent HP DL385 Questions

How To Fix Sun Server Power Supply
(Posted by flippGrowm 9 years ago)
Illegal Opcode
What can cause an illegal opcode error on a DL385p Gen8?
(Posted by ppipathos 9 years ago)
Hp Proliant Dl385 G5p Won't Boot
(Posted by kktxbrad 9 years ago)
Logical Drive State: Background Parity Initialization Is Currently Queued Or In
progress on this logical drive. if background parity initialization is queued, it will start when i/...
(Posted by Lemar 9 years ago)

HP DL385 Videos

HP Proliant DL385 G7 at MIT
Duration: 6:23
Total Views: 81
Server in Action (under 90dBi), HP DL385 G5p
Duration: 1:22
Total Views: 812
HP ProLiant DL385 G6 SixCore Failure Start
Duration: :53
Total Views: 2,503
VMWorld 2010 : SSD vs. HDD Performance Demo on HP DL385 G7
Duration: 3:14
Total Views: 683

Popular HP DL385 Manual Pages

HP ProLiant Servers Troubleshooting Guide - Page 5

... Types of ROM...79 Verifying firmware versions...80 Updating firmware ...81 Unsupported processor stepping with Intel® processors 83 Unsupported processor stepping with AMD processors 84 HP resources for troubleshooting 85 Online resources ...85 HP Technical Support website ...85 HP Guided Troubleshooting website 85 Server documentation ...85 White papers...85 Service notifications ...85...
HP ProLiant Servers Troubleshooting Guide - Page 38

... accidentally unseated during the installation of a new device 4. For more information, see the HP ROM-Based Setup Utility User Guide on page 17) exist. 6. Hardware problems 38 For information on the server. Be sure all cables are using a Smart Array controller, you may receive a POST error message indicating a configuration error. General hardware problems Problems with the hardware...
HP ProLiant Servers Troubleshooting Guide - Page 56

... Insight Diagnostics ("HP Insight Diagnostics" on page 17) exist. 3. Be sure the controller is receiving power, if applicable. 8. Reattempt to connect at which the ISP connects, and change the settings to see if any statuses indicate the source of the problem. Refer to have the line tested. Be sure the server ROM is working by...
HP ProLiant Servers Troubleshooting Guide - Page 60

...® 2000-Emergency Repair Diskette. Software problems 60 Some updates overwrite files specific to access the backup utility. If you start over by removing and reinstalling the problem software, or in some cases by using this step: 1. Perform a full system backup. 2. Install the current drivers ("Drivers" on the HP website (http://www.hp.com/support). Restoring to the documentation...
HP ProLiant Servers Troubleshooting Guide - Page 64

..., refer to support ProLiant BL, ML, and DL servers. Software tools and solutions Configuration tools SmartStart software SmartStart is a collection of utilities and important documentation that describes how to apply these new tools to build an automated server deployment process. The toolkit includes a modular set of software that optimizes single-server setup, providing a simple...
HP ProLiant Servers Troubleshooting Guide - Page 85

...). Select the appropriate server model, and then click the Troubleshoot a Problem link on the HP website (http://www.hp.com/support/gts). HP resources for troubleshooting Online resources HP Technical Support website Troubleshooting tools and information, as well as a PDF or a link on the Documentation CD. Most server documents are available as the latest drivers and flash ROM images, are...
HP ProLiant Servers Troubleshooting Guide - Page 147

...Restore data from www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####) Audible Beeps: None Possible Cause: Drive firmware update needed. expansion progress data lost while a logical expansion operation was lost • Expansion progress data could not be read from array accelerator • Expansion aborted due to unrecoverable drive errors • Expansion aborted due...
HP ProLiant Servers Troubleshooting Guide - Page 187

... problems 62 remote support and analysis tools 76 replacement drives detected 150 required information 172 resources 85 resources, troubleshooting 85 restoring 60 revision history 9 RILOE II (Remote Insight Lights-Out Edition II) 59, 69 ROM error 117, 120, 121, 124 ROM legacy USB support 74 ROM redundancy 73 ROM update utility 83 ROM, types 79 ROM, updating 63, 78 ROM, verifying 80 ROM-Based Setup...
XenServer Administrator's Guide 4.1.0 - Page 105

...4, where 0 is the most verbose and 4 is covered in the XenServer Installation Guide. Our free webbased resources include product documentation, a Knowledge Base, and discussion forums....server logs report only errors and warnings. If you are requested to send a crashdump to the machine that can receive free self-help support via the Support site, or you follow the troubleshooting...
XenServer Virtual Machine Installation 4.1.0 - Page 36

...box. Follow the on-screen prompts to install the new drivers, which attaches the CD image containing the drivers to uninstall the paravirtualized device drivers. Chapter 5. Upgrades to VMs are typically required when moving to update it to Windows 2003, you boot them on the computer is not supported until the paravirtualized drivers are upgraded. • Suspend/Resume of Windows VMs...
XenServer Virtual Machine Installation 4.1.0 - Page 41

... VM (this chapter is reproducible, follow the troubleshooting information in the XenServer Installation Guide. Citrix provides two forms of XenServer Host issues is covered in this procedure to send the dumps to help your XenServer Solution Provider or Citrix Support. C.1.1. VM crashes If you may purchase our Support Services and directly submit requests by filing an...
HP ProLiant DL385 Generation 2 Server User Guide - Page 37

... prompted during the boot process to the HP website (http://www.hp.com/go/supportos). Setup 37 Installing the operating system To operate properly, the server must have a supported operating system installed. For the latest information on or pinched by default for operating system installation. Connect the power cord to the HP ROM-Based Setup Utility User Guide located on the automatic...
HP ProLiant DL385 Generation 2 Server User Guide - Page 62

...page 70) • Installing software drivers directly from each server deployed, making it possible to scale server deployments to the HP website (http://www.hp.com/servers/sstoolkit). The toolkit includes a modular set of utilities and important documentation that have internet connection, the SmartStart Autorun Menu provides access to a complete list of ProLiant system software. •...
HP ProLiant DL385 Generation 2 Server User Guide - Page 67

..., maintenance procedures, failure analysis, corrective service actions, and some utility functions. For operating systems supported by each target server To download the tool and for hardware, firmware, and operating system dependencies, and installs only the correct ROM upgrades required by the server, see the HP website (http://www.hp.com/support). Integrated Lights-Out 2 technology The...
HP ProLiant DL385 Generation 2 Server User Guide - Page 86

... the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) • "CD-ROM and DVD drive problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) • Controller documentation • "Loose connections (on page 77)" "General memory problems are...

HP DL385 Reviews

Do you have an experience with the HP DL385 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.

Popular HP DL385 Search Terms

The following terms are frequently used to search for HP DL385 support:

Ask a New Question
Use the box below to post a new question about HP DL385.
Manuals / Documents
Download any of our HP DL385 manuals for free!

We have the following 28 documents available for the HP DL385:
  • HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet
  • XenEnterprise Management API
  • Important Safety Information - For Server, Storage, Power, Networking, and Rack Products
  • HP ProLiant Servers Troubleshooting Guide
  • HP Insight Control Environment User Guide
  • Microsoft Windows Event ID and SNMP Traps Reference Guide for use with SmartStart version 8.25
  • HP ProLiant DL385 Generation 2 Server User Guide
  • XenServer Administrator's Guide 4.1.0
  • HP BladeSystem Management Pack for Microsoft System Center Essentials 2007 User Guide
  • Sun Solaris 10 Deployment Guide for HP ProLiant Servers
  • XenServer Virtual Machine Installation 4.1.0
  • 18 More!

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP DL385 - ProLiant - G5 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP DL385 - ProLiant - G5 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.