Get support for Hayward EcoStar

Hayward EcoStar Support Question

Hayward EcoStar Support Question

Find answers below for this question about Hayward EcoStar.
Need a Hayward EcoStar manual? We have 3 online manuals for this item!
Question posted by Mp2San on July 8th, 2014

Hayward Ecostar Pentair Intelliflo Which Is Better

The person who posted this question about this Hayward product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
EcoStar Manual - Page 18

Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter to adjust, > go to enter Use + / -
Technical Guide - Page 1

Variable Speed Pump and Drive Technical Guide © 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.55 residential Interface FW 1.00 commercial
Technical Guide - Page 4

...of the pipe and equipment* (fig 1). Plumbing New Pools: When installing the EcoStar on existing pools, care should be taken to ensure proper pipe and ...first elbow or fitting should be taken to handle the maximum flow required (fig 1). Existing Pools: When installing the EcoStar on a new pool, care should be at least 5 times pipe size. MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE...
Technical Guide - Page 7

... Conduit Connections There are two on the pump. Make sure the unit is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in the case ...main or sub-panel and not from the filter pump relay. Bonding Lug 8 AWG (6 AWG for an EcoStar that is both bonded and grounded Page 5 Voltage: 230 VAC, 60Hz, Single Phase. 2. Note: When...
Technical Guide - Page 8

Installation-Interface removal/positioning The interface assembly on the EcoStar can be configured in four different positions. 1. Reposition interface assembly as shown (fig 8). 3. Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Page 6 Remove the interface assembly as shown (fig 7, 9, 10 & 11) and re-secure with the two screws (fig 7). Remove the two screws as shown (fig 7). 2.
Technical Guide - Page 9

... the drive to the interface assembly. Maximum 500‟ for data cable used for connecting to the interface (fig 12). 3. Plug is included with the EcoStar and includes blank cover, mounting bracket and new terminal block for wall mount or control connection. 2. Installation-Interface /Wall mount 1. Wall mount kit is permanently...
Technical Guide - Page 12

... long as shown (fig 22 & 23). Wire 7 on the pump to 2 on the controller, 8 on the pump to 3 on the controller and 1 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to come directly from the main or sub- Note: When connecting high voltage for data cable The data cable...
Technical Guide - Page 22

Same as to continue. 10. Note: When hooked up to a Hayward/Goldline compatible software controls place the MIN and MAX settings at the lowest and highest settings respectively so as #10 above for pipe. See page 3 ...
Technical Guide - Page 24

... 2-14 Set COM Bus Address Lights button Fig 45 Page 22 For EcoStar interface software v2.55 data linked to a Hayward/Goldline compatible software control v4.20 or less will only recognize address 1 (Pool Filter) and address 2 (Dual Spa Filter). Programming-Configuration Hayward/Goldline Compatible Software Control 13. Only the Menu, and Stop/Resume button...
Technical Guide - Page 25

... this screen you will be asked to continue. 16. The default is 41º F. Press the button to continue. 17. Setting will turn on the EcoStar, if stopped, to set the Low Temp Speed ( fig 47). Programming-Configuration 15. Default is 1000 rpm (29%). Enabling this point you will be adjusted...
Technical Guide - Page 26

... setting password protection. Otherwise continue with this point you will be the next to program. Programming-Configuration If you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to page 39 for directions on the next screen. Press the button to continue (fig 50). 19. If the Relay Control or the...
Technical Guide - Page 32

In Auto Prime, pump will begin to operate as long as one of the timer settings matches the current time. 2. If the EcoStar you will be displayed on the display while the pump is pressed. 3. If this does not clear the message the drive may need to restart ...
Technical Guide - Page 35

Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33 The wet end disassembly of the drive and motor area for this guide. Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump.
Technical Guide - Page 41

... 1234 to re-enter if a new one had not been set the Password Timeout in 15 min increments up to continue. 2. If you have a commercial EcoStar you can set . Figure 77 Figure 78 Models HCP3400VSP and HCP3400VSPVR Figure 79 Page 39 If you will be prompted to continue. 3.
Technical Guide - Page 46

... 10). Ohms reading should be sure motor shaft turns freely. Pump will attempt to a Hayward/Goldline Controller, disconnect the com ground wire between interface and drive. If no continuity. If... error still exists remove all (0) check connection between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). Check continuity from the drive and check each ...
Technical Guide - Page 48

...Fault Indications Warning NO Comm Inspect the data wire between the control and EcoStar. If the error has not been eliminated, check the Diagnostic Menu....connected to a GL/Hayward control. Check input wiring and breaker. Page 46 Disconnect the wires from the control. If the values are at "0" replace the interface. EcoStar is tripping. Control reads "Pool bridge comm" This indicates...
Technical Guide - Page 49

wires between the pump interface and the control Check to make sure the Min and Max setting on the EcoStar comm. bus connection and NOT the input connections for Standalone/Hayward. . Control reads "Pool bridge comm." EcoStar is configured for relay control (page 10) . Check the settings in the control filter configuration menu and set...
Technical Guide - Page 50

... changing channel on and off. When a command is connected and operating via the GL/Hayward control. It will not and should not be expected to operate via the GL/Hayward control. When the control is operating the EcoStar, the Speed buttons and the Quick Clean button is actually for relay control. This indicates...
Parts Diagram - Page 1

...Control Interface) Motor Drive Display Cover Motor Drive Wiring Cover Digital Control Interface Assembly Wall Mount Kit HAYWARD 28 25 24 Ctn. No. 1 2 3 4 5 6 7 8 9 10 11 ...Includes Strainer Cover, Lock Ring, O-Ring) Strainer Cover Kit (Biguanide Sanitizer Applications Only; Pumps EcoStar™ SP3400VSP PUMP SERIES REPLACEMENT PARTS Parts for Pump Models: SP3400VSP, SP3400VSPVR 4 5 6 10...

Similar Questions

How To Fix Ecostar Comm Bus Offline & Pro Logic Vsp Comm Error?
I cannot get my Hayward Pro Logic board to communicate with my Hayward Ecostar VSP pump. The pump sa...
(Posted by m72422 7 years ago)
I Recently Lost Power, Now My Ecommand 4 Panel Will Not Turn My Pump On.
I can only turn the pump on and off with the panel breaker. The panel is no longer controlling the p...
(Posted by karenmonroelvnv 9 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls