Question posted by rgardner on November 11th, 2013

Raid Failed Disk Replacement In R820

I have an R820 with a mirroed system disk and a RAID5 raid with a hot spare. One of the RAID disks failed and the hot spare rebuilt automatically. I now have the replacement disk for the failed unit. If I hot swap it in, how do I make it the new hot spare? Or will the system automatically rebuild the new disk and return the hot spare to "hot spare" status?

Current Answers

Answer #1: Posted by GeoffatDell on November 11th, 2013 3:55 PM
This answer was accepted by the poster of the original question.
GeoffatDell

Member since:
June 25th, 2012

Points: 24,740
1,110
points
Insert the drive, and it should begin to the process of rebuilding again. Once its finished, it should take its place in the array and your hotspare will return to hotspare status.

Regards,

Related Dell PowerEdge R820 Manual Pages

Glossary - Page 5

... record. memory module - MHz - Mirroring functionality is monitored and managed using Dell OpenManage™ Server Administrator. Millimeter(s). ms - NAS - Your system's unique hardware number on a network. Megabit...stores basic system data. mAh - MAC address - See also striping and RAID. A portable flash memory storage device integrated with a USB connector. Managed ...
Glossary - Page 6

... peripheral - The primary computational chip inside the system that provides electrical power to servers and storage systems in rows and columns to run on your system. Nanosecond(s). ... called partitions with the format command. Peripheral Component Interconnect. Power distribution unit. PowerEdge RAID controller. pixel - Pixels are arranged in a rack. Before the ...
Glossary - Page 7

...ROM include the program that enables remote networkattached storage devices to appear to a server to the system BIOS and then display an error message on motherboard. Secure ...Any information stored in RAM is most often used to the system. SAN - RAID - Some common implementations of independent disks. RAM - service tag - Second(s). A standard interface between the system board and...
Glossary - Page 8

...automatically supplies power to enable or disable the termination on these devices by changing jumper or switch settings on each disk used by an operating system, where each disk. TOE - The amount of disks...protection. See also guarding, mirroring, and RAID. Super video graphics array. As the main.... A battery-powered unit that has two or more disks in the configuration software...
Glossary - Page 46

... Media Access Control mAh - Megabit 1 Mb = 1,048,576 MB - Megabits per second MBR - Millimeter MOF - Object Identifier PCI - PowerEdge RAID 46 Managed Object Format CIM ASCII ms - Nanosecond NVRAM - Power distribution unit PDU PERC - Megabytes per second MBps - Master boot record MHz - Nonmaskable interrupt NMI ns - Peripheral Component Interconnect PDU...
Glossary - Page 47

...65289;。 SAN - Random-access memory RAM readme ROM - Storage Area Network SAS - Redundant array of independent disks RAID には、RAID 0、RAID 1、RAID 5、 RAID 10 RAID 50 RAM - Synchronous dynamic random-access memory sec - Second(秒)。 SEL - Serial-attached SCSI SCSI)。 SATA - Serial Advanced Technology...
Glossary - Page 56

... Network Interface Controller NMI Nonmaskable Interrupt NMI ns Nanosecond NVRAM Nonvolatile Random-Access Memory NVRAM OID Object Identifier PCI Peripheral Component Interconnect PDU Power Distribution Unit PERC - PowerEdge RAID POST Power-On Self-Test POST RAM PXE Preboot eXecution Environment LAN R-DIMM DDR3 Registered DDR3 Memory Module 56
Glossary - Page 57

RAC Remote Access Controller RAID Redundant Array of Independent Disk RAID RAID 0, RAID 1, RAID 5, RAID 10 및 RAID 50 RAM Random-Access Memory RAM ROM Read-Only Memory ROM ROM ROM POST ROMB RAID(RAID On Motherboard SAN Storage Area Network SAS SCSI(Serial-Attached SCSI SATA Serial Advanced Technology Attachment SCSI Small Computer System Interface I /O SNMP...
Owner's Manual - Page 1

Dell PowerEdge R820 Owner's Manual Regulatory Model: E21S Series Regulatory Type: E21S001
Owner's Manual - Page 22

...or disable a one of the system. By default, the Integrated RAID Controller option is set to UEFI disables BIOS Boot Settings menu....to Mirror. Data from this option to On. Allows you to the replacement SD card at the next boot. CAUTION: Switching the boot mode may... to UEFI. If set the boot mode of the SD card fails, data is written to BIOS. Boot Settings Screen Menu Item Boot...
Owner's Manual - Page 50

... that is not authorized by Dell is not supported. 50 hard-drive carrier handle Installing A Hot-Swap Hard Drive CAUTION: Many repairs may only be removed safely. CAUTION: Use only hard drives ...See the documentation supplied with the hard-drive backplane. Insert a hard-drive blank in the same RAID volume is not covered by your operating system. 1. Figure 19. Wait until it is ready ...
Owner's Manual - Page 51

... installing a hard drive, ensure that you wish to have over-written. CAUTION: When a replacement hot-swappable hard drive is installed and the system is installed. 1. Make absolutely sure that your... your operating system supports hot-swap drive installation. See the documentation supplied with the backplane. 5. Press the release button on , the hard drive automatically begins to lock the ...
Owner's Manual - Page 101

...: Take care not to servicing that came with the product. 1. system board 2. Hold the touch points and lower the system board into place. 4. Replace the following: a) hard-drive backplane b) hot-swap hard drives c) if installed, internal USB key d) internal dual SD module e) network daughter card f) heat sinks/processors g) expansion-card risers, expansion cards...
Owner's Manual - Page 131

... the operating requirements for PSU is not configurable. Error Code Message Information Action Remove and re-seat the failed disk. Re-seat the failed drive. PST0128 Message LCD Message Details Action No memory is removed from disk drive bay . Check PSU. LCD Message Predictive failure on power supply . If the issue persists, see Getting...
Technical Guide - Page 5

...Server Management 41 16.3 Embedded Server Management 41 16.3.1 Unified Server Configurator 42 16.3.2 Base Management Functionality 42 17 Peripherals 43 Appendix A. Product Features Summary 10 Table 3. Shock and Vibration Specifications 20 Table 7. Supported Processors 23 Table 9. Factory RAID...Power Button 15 LED Control Panel 16 PowerEdge T110 II Technical Guide v Ergonomics, ...
Technical Guide - Page 6

... the next level. Adding a server to your business gives you to focus on PowerEdge servers. Your data can further protect your data by providing automatic backup and restore functionality, as ... file access with the Microsoft Windows Small Business Server 2011 standard backup features that let you can be secured using RAID options for small businesses considering or implementing desktop ...
Technical Guide - Page 11

...1000 PT Server Adapter Intel Gigabit ET Dual Port Server Adapter Power Supply Single cabled power supply (305W) Availability Video Quad-pack LED diagnostics, ECC memory, add-in RAID, TPM/TCM...microsoft.com/fwlink/?LinkId=143551 PowerEdge T110 II Technical Guide 11 If not configured according to the product documentation, the software will be less. 2Windows Server 2008 R2 Foundation SP1 ...
Technical Guide - Page 18

...control (server management functions). PowerEdge T110 II Technical Guide 18 Dell 5 Power, Thermal, Acoustic 5.1 Power Supplies The base PowerEdge T110 II... system includes a single 305W power supply. Power Supply Specifications Non-redundant Power Supply L-140mm x W-150mm x H-98mm N/A Yes Yes AC Cord Rating Input Voltage Auto-ranging Line Frequency Maximum Inrush Current Hot-Swap...
Technical Guide - Page 21

... Power Supply Tape Drives PCI Cards Idle 4.2 None Active hard drives 4.2 Stressed processor 4.2 RAID Operating Mode LwA-UL (bels) 27 None 27 None 27 None LpA Prominent (dBA) Tones...they are listed in exercising the hard disk drives. LwA-UL: The upper limit sound power level (LwA) calculated per ISO7779 (1999) definition 3.1.6; PowerEdge T110 II Technical Guide 21 Dell &#...
Technical Guide - Page 42

... utility are supported on the PowerEdge T110 II:  IPMI v2.0 support  Conductivity: o Shared/failover network modes o IPv4 o VLAN tagging o Dynamic DNS  Security and authentication: o Role-based authority o Local users  Remote management and remediation: o Server power control o Serial-over-LAN (with Dell support automatically directed to previous ―known...

Similar Questions

Dell Server Poweredge R710 Error Message Error 1
hi Good Day,we are having issue with our dell R710 with error message error 1 but we look up in OMSA...
(Posted by jillustrisimo32 4 years ago)
Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge R820 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.