Get support for Dell PowerEdge M1000e

Dell PowerEdge M1000e Support Question

Dell PowerEdge M1000e Support Question

Find answers below for this question about Dell PowerEdge M1000e.
Need a Dell PowerEdge M1000e manual? We have 32 online manuals for this item!
Question posted by hildjanel on January 25th, 2014

What Is The Minimum Amount Of Power Supplies Required To Run The M1000e

The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Dell PowerEdge M1000e Manual Pages

Dell PowerEdge M1000e Configuration Guide - Page 27

... 1-4. CAUTION: Do not turn on the blades (server modules) until you need the IP address, subnet mask, and gateway to configure the CMC and other modules in a rack. Initial System Configuration 27 The power supplies require a 100-120 V or 200-240 V power source. You can select only one AC power input, as described in "Configuring the...
Hardware Owner's Manual - Page 35

Power Supply Indicator NOTE: The power supplies must be connected to a PDU, not directly to an electrical outlet. • The power supplies require a 200-240 V power source. • A 2700 W power supply can be connected to a 110 V AC power source. Power Supply Indicators 1 2 3 1 DC power output indicator 3 AC power present indicator 2 power supply fault indicator About Your System 35 ...
Hardware Owner's Manual - Page 265

...2360 W and 2700 W power supply modules require 200-240 V input from the enclosure back panel. The CMC module controls power management for the system. Power Supply Modules The M1000e enclosure supports up to six hot-swappable power supply modules, accessible from a PDU. A power supply module must be replaced if an internal fan failure occurs. The power supplies are plugged into 110...
Hardware Owner's Manual - Page 341

... link, 45 CMC link activity, 45 CMC status, 45 fan module, 36 Fibre Channel pass-through module, 68, 70, 84, 90 power supply, 35 power supply fault, 36-37 server module power selection, 29 system power, 17 installing battery, 245 blades, 148 CMC module, 273-274 expansion card, 218 fans, 270 hard drive in a drive carrier, 249...
Hardware Owner's Manual - Page 343

... features, 14 accessing, 13 system password, 140 system password features, 140 system power button, 17 system power indicator, 17 system setup options, 129 using, 128 system setup program entering, ... drive, 298 keyboard, 289 memory, 297 mouse, 289 network switch module, 296 power supplies, 292 processors, 300 server module components, 297 start-up routine, 287 USB devices, 290 U UEFI Boot Manager...
Fabric OS Command Reference Manual Supporting Fabric - Page 974

...status for details on the calculation of the following contributors: • Power supplies • Temperatures • Fans • WWN servers (dual-CP systems only) • Standby CP (dual-CP systems... IP address: 1080::8:800:200C:417A SwitchState: MARGINAL Duration: 80:12 Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal ports monitor Faulty ports monitor...
Fabric OS MIB Reference - Page 257

...94.1.6.1.5 Overall state of supported ports are as follows: switchState(ONLINE) 2 (online) switchState(not ONLINE) 3 (offline, testing, faulty) connUnitStatus 1.3.6.1.3.94.1.6.1.6 Overall status of contributors like Power supplies, Temperatures, Fans, WWN servers, Standby CP, Blades, Flash, Marginal ports, Faulty ports, Missing SFPs, and so on. The maximum number of the connectivity unit.
Fabric OS Release Notes - Page 18

Power Supply Requirements for redundancy. Cannot be used in a chassis with other intelligent blades (can only be used in a DCX/DCX-4S chassis with three or more FS8-18 Blades, (2+2) 220VAC Power Supplies are required for redundancy. • For DCX-4S, (2) 220VAC Power Supplies provide 1 FC8-64 is not supported on DCX/DCX-4S Fabric OS v6.4.1 Release Notes...
Fabric OS Release Notes - Page 19

...Dynamic Load Sharing (DLS, port based routing) Yes Virtual Channels (VC RDY) Yes2 FICON Management Server (Cascading) Yes FICON MIHPTO Yes Full Scalability (to maximum M-EOS fabric limits) Yes Yes Yes... (McDATA Fabric Mode) or interopmode 3 (Open Fabric Mode) with Fabric OS v6.4. Blades Power Supply Requirements for Blades in 48k and DCX/DCX-4S Chassis Type of Blade 48K @200-240 VAC (...
Technical Guide - Page 9

.... Comprehensive I/O options to support dual links of 40 Gigabits per second today (with 4x QDR InfiniBand®) with future support of the power supplies available to all server modules. PowerEdge M1000e Technical Guide 8 Thorough power-management capabilities including delivering shared power to the network and storage now and well into the future. Up to 6 hot-pluggable, redundant...
Technical Guide - Page 10

... The Dell PowerEdge M1000e Modular Server Enclosure is a breakthrough in slots 4, 5, and 6. 1+1 2+1 3+1 4+1 5+1 Each with one of the existing power supplies fails. PowerEdge M1000e Technical Guide ...Control Panel, Graphical LCD Control Panel 3+3 2+2 1+1 Each requires power supplies in slots 1, 2, and 3 to be connected to a different grid as compared to those in enterprise server architecture.
Technical Guide - Page 13

... provide a fully redundant, active‐standby fault-tolerant solution for the fans. For more information, see Back-Panel Features in lower airflow requirements for management access and control. Power Supply Indicators PowerEdge M1000e Technical Guide 12 The enclosure ships by default with a single CMC, with the option of airflow through the system, allowing lower pressure...
Technical Guide - Page 28

... the 12V system bus. With current sharing between power supplies, total system redundant power is supported in the following configurations, each with one extra power supply that comes online if one of which requires the power supplies in the following configurations, each of the existing power supplies fails: PowerEdge M1000e Technical Guide 27 AC redundancy is supported in...
Technical Guide - Page 30

... the CMC, which could result in a spontaneous activation of power supply over current protection without the excess margin required in the CMC. Since the CMC controls when every modular system element powers on the other enterprise-level management tools. I/O modules, on , it is also about power management. The M1000e power supplies continuously monitor AC input current, voltage and...
Technical Guide - Page 31

... the minimum number of an air-moving device is coupled with a high‐efficiency air-moving device designed explicitly for the M1000e supports a low‐impedance, high‐efficiency design philosophy. The low impedance design is defined as part of the system. The efficiency of supplies required to report the total power consumed by the server...
Technical Guide - Page 32

... front‐to run the fan. Figure 25. Server Cooling Air Profile The Server Modules are cooled with independent airflow paths. I /O Modules, and Power Supplies are plenums both upstream of the midplane, between the midplane and the blades, and downstream of each module. The Server Modules, I /O Module Inlet and IOM Locations PowerEdge M1000e Technical Guide 31...
Technical Guide - Page 33

PowerEdge M1000e Technical Guide 32 Figure 28. This insures that the power supplies receive ambient temperature air. I/O Cooling Air Profile The I/O ...figure. Power Supply Inlet and Cooling Air Profile The Power Supplies, located in the rear of the system to the I /O Modules in a top to ‐back cooling, but draw their inlet air from a duct located beneath the server modules, ...
Technical Guide - Page 34

... slot priority order from #6. 10. The first power supply provides a small amount of electricity which starts up the power supply units. 3. CMC begins to boot and power up the first CMC. 2. Active CMC powers up . 9. iKVM is based on temperature conditions on the server module, as well as required to maintain Server and I/O Module airflow at optimal levels. 5.4 Environmental...
Technical Guide - Page 69

...: o Time to save and back up the data being processed o Safely power down your servers o Support for up to 5000 VA (3750 watts) • Power distribution units (PDUs): use the Dell Energy Smart Solution Advisor (ESSA) to see what a given chassis configuration will require. PowerEdge M1000e Technical Guide 68 Dell 15 Peripherals Common peripherals for the...
Getting Started Guide - Page 9

... Requirements 2700 W Molex # 394260002 at PSU end, mating connector Molex # 39422-0012 1205 BTU/hr (maximum) Under typical input voltage conditions and over the entire system ambient operating range, the inrush current may reach 55 A per power supply for 10 ms or less. Physical - Blades Coin-cell battery 3 V CR2032 Lithium coin cell Power - Power - Blades PowerEdge...

Similar Questions

Dell Poweredge 180as: Failed Dve Dso-142l Power Supply .
NASA equipment: Power supply voltage is +5.1v (good), and -3.8v (s/b -5.0v). Seems to be a lot of ...
(Posted by WilliamGAycock 11 years ago)
Power Supply
Can the Dell PowerEdge R900 run on one single power supply?  Thank you!
(Posted by wlin 12 years ago)
Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge M1000e manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.