Dell PowerConnect 2724 Support Question
Find answers below for this question about Dell PowerConnect 2724.Need a Dell PowerConnect 2724 manual? We have 5 online manuals for this item!
Question posted by 28bubus on January 31st, 2014
How To Reset Powerconnect 2724
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerConnect 2724 Manual Pages
Information Update - Page 1
.... In this switch, follow the steps in the User's Guide for DellTM PowerConnectTM 2708, 2716, and 2724
NOTE: The PowerConnect 27xx switches are shipped as a Web-managed switch.
March 2005 NOTE... see the Dell PowerConnect 27xx Systems User's Guide. It is advisable to prevent accidental mode changes.
When changing to the Web-managed mode, the switch is reset to take advantage ...
User's Guide - Page 3
... Address Supported Features 11 Layer 2 Features 11 VLAN Supported Features 12 Class of Service (CoS) Features 12 Ethernet Switch Management Features 13 Port Default Settings 13
2 Hardware Description
Switch Port Configurations 15 PowerConnect 2708/2716/2724/2748 Front Panel Port Description . . . . 15
Physical Dimensions 19
LED Definitions 19 Power LED 19 Managed Mode LED...
User's Guide - Page 7
..., such as: • Servers • Hubs (Wireless LAN Access Points) • Routers The PowerConnect devices are primarily for installing, configuring and maintaining the PowerConnect 2708, PowerConnect 2716, PowerConnect 2724, and PowerConnect 2748 Webmanaged Gigabit Ethernet switches. PowerConnect 2708 Front Panel
The PowerConnect 2708 switch supports 8 GbE copper ports.
7 System Description...
User's Guide - Page 8
... copper ports and has two SFP combo ports (1000BASE-SX or 1000BASE-LX).
48 1-Gigabit Ethernet Ports
The following figure illustrates the PowerConnect 2724 front panel. PowerConnect 2748 Front Panel
8 Figure 1-2. PowerConnect 2716 Front Panel
The PowerConnect 2716 switch supports 16 GbE copper ports.
24 1-Gigabit Ethernet Ports + 2 SFP Combo ports
The following figure illustrates the...
User's Guide - Page 11
... auto-learning from overflowing.
MAC Address Supported Features
MAC Address Capacity Support The PowerConnect 2708, 2716, and 2724 switches support a total of 8K MAC addresses, and the PowerConnect 2748 supports a total of Multicast and Broadcast frames accepted and forwarded by the switch. However, a similar functionality may be configured for a given period of all ports on...
User's Guide - Page 12
Link Aggregation The PowerConnect 2708/2716/2724/2748 switches support up to four member ports to full-duplex operation. BootP and ...to be grouped in the same VLAN.
Class of Service (CoS) Features
The PowerConnect 2708/2716/2724/2748 system enables users to all ports on a combination of switching ports that comprise a single broadcast domain. The BootP client is operational if ...
User's Guide - Page 13
.... After a packet has been classified, it is defined by the user, whereby packets are established or enforced. TFTP Trivial File Transfer Protocol The PowerConnect 2708/2716/2724/2748 switches support software boot image and software download through which the system can classify according to IPv4 information (DSCP).
The system provides a means to collect...
User's Guide - Page 15
... ports can operate at 1000 Mbps, full-duplex mode. On each port there are numbered 1 to 8, top down and left side of the PowerConnect 2708/2716/2724/2748 switches. The following figures illustrate the front panels and back panels of the front panel is powered on the front panel, restores the device's default...
User's Guide - Page 17
... switch from the RJ-45 to the SFP (or vice versa) without resetting...switch operational status. A Managed Mode push-button, located on the far right side on a combo port, and utilizes the information in all the control interfaces. The system automatically detects the media used . Port features and port controls are LEDs to right. On the left to indicate the port status. PowerConnect 2724...
User's Guide - Page 19
... the following physical dimensions:
• Height - 43.2 mm (1.7008 in.) • Width - 256 mm (10.079 in.) • Depth - 161.7 mm (6.366 in.) The PowerConnect 2716 and PowerConnect 2724 switches have the following physical dimensions:
• Height - 43.2 mm (1.7008 in.) • Width - 330 mm (12.992 in.) • Depth - 230.50 mm (9.075...
User's Guide - Page 21
...off.
• The device is linked at 1000 Mbps.
Managed Mode Button
The PowerConnect 2708/2716/2724/2748 has a Managed Mode push button on the front panel. Green Flashing Activity...is not configured (appears blank), with Read/Write privilege.
• The DHCP client is set as the switch IP address.
• Subnet mask changes to 255.255.255.0
• Graphical User Interface (GUI) login...
User's Guide - Page 22
...Connections for all four wire pairs are connected. High-speed workstations, hubs, routers, or other switches are used for 10/100/1000BASE-T Ports
The 10/100/1000BASE...table. 22
The PowerConnect 2708 and PowerConnect 2716 devices have no internal fans. Figure 2-10. Table 2-6. Switch Ventilation Fan
The PowerConnect 2748 switch has three fans and the PowerConnect 2724 switch has one fan...
User's Guide - Page 23
...
2
TxRx 1-
3
TxRx 2+
4
TxRx 2-
5
TxRx 3+
6
TxRx 3-
7
TxRx 4+
8
TxRx 4- PowerConnect 2724 switch supports SFP diagnostics.
NOTE: If both RJ-45 and SFP ports are present, the SFP port will be the active... port can be monitored and displayed to the SFP (or vice versa) without a system reset. Table 2-7.
The system automatically detects the media used at any time. Only one of ...
User's Guide - Page 24
... AC coupled.
13
Receiver non-inverted data out; Internal Power Supply Connector
The PowerConnect 2708, PowerConnect 2716, PowerConnect 2724 and PowerConnect 2748 switch systems supports a single internal power supply to provide power for serial ID.
5
Module definition 1; data line for switching operations. grounded within the module.
7
Rate select; laser output disabled on the...
User's Guide - Page 25
...hardware enclosure, as explained in Unmanaged Mode. The process of installing the PowerConnect switch consists of physically installing these devices and configuring them. These components are standard 1U ...chassis high, 19-inch rack-mountable devices. Overview
The PowerConnect 2708/2716/2724/2748 are to be serviced by trained service technicians only. • Ensure...
User's Guide - Page 26
.... Cabling is adequate frontal clearance for Managed Mode Operation" explains how to set the switch to avoid sources of a grounded, easily accessible outlet
220/110 VAC, 50/60 Hz...remove the cover on the wall. The chapter "Starting and Configuring the Dell™PowerConnect™ 2708/2716/2724/2748 for operator access. Allow clearance for the device meets the following label attached...
User's Guide - Page 33
... proceeding, read the release notes for this chapter. The release notes can simply plug the switch in and start using it is off if in Unmanaged Mode, and solid green if in the PowerConnect 2708/2716/2724 switch the Managed Mode LED indicator turns solid red. The boot process runs approximately 10 seconds. When...
User's Guide - Page 55
... Files From Server
The File Download page contains fields for downloading files from which file is downloaded. This applies to PowerConnect 2748 switch configuration only. Destination File -
File Download (PowerConnect 2708, 2716, and 2724 Switch Configuration)
TFTP Server IP Address - Downloading Files from the TFTP server. Downloads the software image file. To open the page...
User's Guide - Page 66
... open the page, click Storm Control in terms of
number of packets per second. • Enable or disable packet storm control, on the PowerConnect 2716/2724 The PowerConnect 2716 and PowerConnect 2724 switches measure the rate of Broadcast threshold ranges from 70-285,000 packets per second. Disable counts only Broadcast traffic. The Storm Control port...
User's Guide - Page 67
... the storm control is enabled. Configuring Storm Control on the types of traffic are saved to the PowerConnect 2716/2724 switch. Storm Control Page (PowerConnect 2748 Switch Configuration)
Port - Sets the mode of Broadcast Storm Control based on the PowerConnect 2748 The following describes Storm Control for types of traffic selected. Port - Enables or disables forwarding...