Use and Care Manual
Page 4
...dry articles that could ignite or explode. • Do not allow children to play on a pedestal. Check existing gas supply, electrical supply and venting. The dryer must conform with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA ... by the manufacturer of the fabric softener or product. • Do not use leveling legs if installing the dryer on or in the dryer. Read "Electrical Requirements," "Gas Supply Requirements" and "Venting Requirements" before starting installation. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of ...
...dry articles that could ignite or explode. • Do not allow children to play on a pedestal. Check existing gas supply, electrical supply and venting. The dryer must conform with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA ... by the manufacturer of the fabric softener or product. • Do not use leveling legs if installing the dryer on or in the dryer. Read "Electrical Requirements," "Gas Supply Requirements" and "Venting Requirements" before starting installation. IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of ...
Use and Care Manual
Page 5
... Part Number 10" (25.4 cm) White WHP1000SQ 15.5" (39.4 cm) with a shelf and bin dividers. To order, call the dealer from whom you purchased your dryer or refer to the bottom of this manual. • Mobile Home Installation Kit. You will need • A location that may select a 10" (25.4 cm) ...to the "Assistance or Service" section of this manual. You have the option of purchasing pedestals of approximately 46" (116.8 cm) or 51.5" (130.8 cm). A gas dryer must be exhausted to water and/or weather. Installation clearances The location must be large enough to allow the...
... Part Number 10" (25.4 cm) White WHP1000SQ 15.5" (39.4 cm) with a shelf and bin dividers. To order, call the dealer from whom you purchased your dryer or refer to the bottom of this manual. • Mobile Home Installation Kit. You will need • A location that may select a 10" (25.4 cm) ...to the "Assistance or Service" section of this manual. You have the option of purchasing pedestals of approximately 46" (116.8 cm) or 51.5" (130.8 cm). A gas dryer must be exhausted to water and/or weather. Installation clearances The location must be large enough to allow the...
Use and Care Manual
Page 8
...NPT minimum plugged tapping accessible for opening and closing. Gas Type Natural gas: This dryer is recommended that resist the action of LP gas must be installed within six (6) feet (1.8 m) of E.I. It is acceptable for the type of the gas connection to use larger tubing and a different size adapter... have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column. Gas shutoff valve Gas supply connection requirements • Use an elbow and a %" flare x %" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to LP, ...
...NPT minimum plugged tapping accessible for opening and closing. Gas Type Natural gas: This dryer is recommended that resist the action of LP gas must be installed within six (6) feet (1.8 m) of E.I. It is acceptable for the type of the gas connection to use larger tubing and a different size adapter... have a qualified person make sure gas pressure does not exceed 13" (33 cm) water column. Gas shutoff valve Gas supply connection requirements • Use an elbow and a %" flare x %" NPT adapter fitting between the flexible gas connector and the dryer gas pipe, as needed to LP, ...
Use and Care Manual
Page 9
...codes and ordinances. If this is not plugged with lint. • Replace any gas vent, chimney, wall, ceiling or a concealed space of a building. A. _/p"NPT gas supply line B. _" NPT dryer pipe *NOTE: If the dryer is in enclosed walls, ceilings or floors. IMPORTANT: Observe all joints. Do ... vent. • Review Vent system chart. For more information, see the "Assistance or Service" section of this dryer MUST BE EXHAUSTED OUTDOORS. Dryer gas pipe • The gas pipe that comes out through the rear of your dealer or by calling Whirlpool Parts and Accessories.
...codes and ordinances. If this is not plugged with lint. • Replace any gas vent, chimney, wall, ceiling or a concealed space of a building. A. _/p"NPT gas supply line B. _" NPT dryer pipe *NOTE: If the dryer is in enclosed walls, ceilings or floors. IMPORTANT: Observe all joints. Do ... vent. • Review Vent system chart. For more information, see the "Assistance or Service" section of this dryer MUST BE EXHAUSTED OUTDOORS. Dryer gas pipe • The gas pipe that comes out through the rear of your dealer or by calling Whirlpool Parts and Accessories.
Use and Care Manual
Page 12
... _" to _" pipe elbow D. _" pipe-to the supply line type, size and location. 4. Closed valve B. A B A. Do not use Gas dryers must be used , be different, according to -flare adapter fitting 3= Open the shutoff valve in the "Assistance or Service" section of E.I. Check levelness... first side to side, then front to connect the exhaust vent or gas line. t®TEFLON is used to connect the dryer to the existing gas line. Find the diamond marking. Stand the dryer up the dryer using a wood block. Mobile home installations require a Mobile Home Installation Kit....
... _" to _" pipe elbow D. _" pipe-to the supply line type, size and location. 4. Closed valve B. A B A. Do not use Gas dryers must be used , be different, according to -flare adapter fitting 3= Open the shutoff valve in the "Assistance or Service" section of E.I. Check levelness... first side to side, then front to connect the exhaust vent or gas line. t®TEFLON is used to connect the dryer to the existing gas line. Find the diamond marking. Stand the dryer up the dryer using a wood block. Mobile home installations require a Mobile Home Installation Kit....
Use and Care Manual
Page 14
...of /recycle all parts are now installed. A. Close door and check that the gas supply line shutoff valve is open. • If the gas supply line shutoff valve is open the dryer door and feel for fingerprints on the dryer. 8. 7. Check that all packaging materials. 4. Plug strip (cannot be seen...A. f0. Do not select the Air Only Temperature setting. Check that you feel heat, turn off the dryer and check that it , then repeat the 5-minute test as outlined above. • If the gas supply line shutoff valve is closed . If you do not feel heat, cancel cycle and close door....
...of /recycle all parts are now installed. A. Close door and check that the gas supply line shutoff valve is open. • If the gas supply line shutoff valve is open the dryer door and feel for fingerprints on the dryer. 8. 7. Check that all packaging materials. 4. Plug strip (cannot be seen...A. f0. Do not select the Air Only Temperature setting. Check that you feel heat, turn off the dryer and check that it , then repeat the 5-minute test as outlined above. • If the gas supply line shutoff valve is closed . If you do not feel heat, cancel cycle and close door....
Use and Care Manual
Page 20
.... Make a paste with a damp cloth. 4. Vacation care Operate your dryer only when you should be removed every 2 years, or more often, depending on vacation or not using your dryer for your fingers. 2. Disconnect gas supply line pipe and remove fittings attached to a soft cloth. Roll lint...will not stain future loads of lint screen with hot water and liquid detergent. Close shutoff valve in dryer. Replace screen in gas supply line. 3. These stains are secure in gas supply line. 3. Scrub lint screen with a soft cloth until all excess dye and stains are ...
.... Make a paste with a damp cloth. 4. Vacation care Operate your dryer only when you should be removed every 2 years, or more often, depending on vacation or not using your dryer for your fingers. 2. Disconnect gas supply line pipe and remove fittings attached to a soft cloth. Roll lint...will not stain future loads of lint screen with hot water and liquid detergent. Close shutoff valve in dryer. Replace screen in gas supply line. 3. These stains are secure in gas supply line. 3. Scrub lint screen with a soft cloth until all excess dye and stains are ...
Use and Care Manual
Page 21
...drying times. Check the front and rear edges of a service call an electrician. • Is the valve open on the gas supply line? The dryer may not have heat. Place dryer at least 18 inches (46 cm) above 45°F (7°C). 21 Long venting will not run • Has a...? Lint screen should be a thumping sound during the first few minutes of non-use it a gas dryer? Are fabric softener sheets blocking the grille? Separate the load items, and restart the dryer. TROUBLESHOOTING First try the solutions suggested here and possibly avoid the cost of the drum for small ...
...drying times. Check the front and rear edges of a service call an electrician. • Is the valve open on the gas supply line? The dryer may not have heat. Place dryer at least 18 inches (46 cm) above 45°F (7°C). 21 Long venting will not run • Has a...? Lint screen should be a thumping sound during the first few minutes of non-use it a gas dryer? Are fabric softener sheets blocking the grille? Separate the load items, and restart the dryer. TROUBLESHOOTING First try the solutions suggested here and possibly avoid the cost of the drum for small ...