User Manual
Page 365
... the independent variable. Moves vertically (either up or down) to trace the web and display its coordinates. For example, consider the sequence u1(n) = 5 - The TI-89 Titanium draws the y=x reference line and then plots y = y = 5 - to the sequence. Drawn automatically. This effectively converts a recursive sequence into a nonrecursive form for graphing. ...on the x axis at the initial value ui (when plotstrt = 1). 2. If Build Web = TRACE The web is plotted, the web may be displayed manually or automatically, depending on how you do in other graphing modes. You can then press ...
... the independent variable. Moves vertically (either up or down) to trace the web and display its coordinates. For example, consider the sequence u1(n) = 5 - The TI-89 Titanium draws the y=x reference line and then plots y = y = 5 - to the sequence. Drawn automatically. This effectively converts a recursive sequence into a nonrecursive form for graphing. ...on the x axis at the initial value ui (when plotstrt = 1). 2. If Build Web = TRACE The web is plotted, the web may be displayed manually or automatically, depending on how you do in other graphing modes. You can then press ...
User Manual
Page 457
...on initial values • That matches Graph screen A manual table tblStart @tbl Graph < - > Table Independent value value - - - - Changing the Setup Parameters From the TABLE SETUP dialog box: Tables 457 The TI-89 Titanium automatically generates a series of table. Which Setup Parameters to... prior values. Note: The table initially starts at tblStart, but you build a table manually by entering specific values for tblStart and @tbl. OFF ON...
...on initial values • That matches Graph screen A manual table tblStart @tbl Graph < - > Table Independent value value - - - - Changing the Setup Parameters From the TABLE SETUP dialog box: Tables 457 The TI-89 Titanium automatically generates a series of table. Which Setup Parameters to... prior values. Note: The table initially starts at tblStart, but you build a table manually by entering specific values for tblStart and @tbl. OFF ON...
User Manual
Page 464
... saved in the independent variable column. Displaying the Table Screen To display the Table screen, press ¹ '. Building a Manual (Ask) Table If Independent = ASK on the TABLE SETUP dialog box, the TI-89 Titanium lets you can change its setup parameters as necessary. The cursor highlights the first cell in the Y= Editor. Press...
... saved in the independent variable column. Displaying the Table Screen To display the Table screen, press ¹ '. Building a Manual (Ask) Table If Independent = ASK on the TABLE SETUP dialog box, the TI-89 Titanium lets you can change its setup parameters as necessary. The cursor highlights the first cell in the Y= Editor. Press...
User Manual
Page 634
...Programming 634 Command GetCalc SendCalc Description Executed on the sending unit. Sends a variable to "Transmitting Variables under Program Control" in Connectivity. Accessing Another TI-89 Titanium When two calculators are executed in the proper sequence, refer to the receiving unit via the I /O port. • Before the sending unit executes... via the I /O port. • After the receiving unit executes GetCalc, the sending unit must execute GetCalc. Sets up the unit to the manual that GetCalc and SendCalc are linked, one acts as a receiving unit and the other as a sending unit.
...Programming 634 Command GetCalc SendCalc Description Executed on the sending unit. Sends a variable to "Transmitting Variables under Program Control" in Connectivity. Accessing Another TI-89 Titanium When two calculators are executed in the proper sequence, refer to the receiving unit via the I /O port. • Before the sending unit executes... via the I /O port. • After the receiving unit executes GetCalc, the sending unit must execute GetCalc. Sets up the unit to the manual that GetCalc and SendCalc are linked, one acts as a receiving unit and the other as a sending unit.