Print Specs
Page 1
... 9-pin x 1 (Control port) RJ-45 x 1 (Wired LAN) Mini jack x 1 (Wired R/C) USB (type B) x 1 Power cord VGA cable Lens mount cover Lens attachment Remote control AAA battery x2 Quick reference guide Owner's Manual (CD-Rom) Network Owner's Manual PIN code label Light block sheet USB cable... multiple projector usage. QUADRIVETM ENGINE ALLOWS RICH COLOR AND HIGH CONTRAST SANYO's Unique QuaDriveTM engine evolves into a new generation standard. CRESTRON ROOMVIEWTM /AMX DEVICE DISCOVERY COMPATIBILITY PLC-HP7000L supports Crestron RoomViewTM and AMX Device Discovery which darken the screen in...
... 9-pin x 1 (Control port) RJ-45 x 1 (Wired LAN) Mini jack x 1 (Wired R/C) USB (type B) x 1 Power cord VGA cable Lens mount cover Lens attachment Remote control AAA battery x2 Quick reference guide Owner's Manual (CD-Rom) Network Owner's Manual PIN code label Light block sheet USB cable... multiple projector usage. QUADRIVETM ENGINE ALLOWS RICH COLOR AND HIGH CONTRAST SANYO's Unique QuaDriveTM engine evolves into a new generation standard. CRESTRON ROOMVIEWTM /AMX DEVICE DISCOVERY COMPATIBILITY PLC-HP7000L supports Crestron RoomViewTM and AMX Device Discovery which darken the screen in...
RS232C Basic
Page 3
... 1 DVI (PC DIGITAL) Command 19 6.51 INPUT 1 DVI (AV HDCP) Command 19 6.52 LENS SHIFT UP Command 20 6.53 LENS SHIFT DOWN Command 20 6.54 LENS SHIFT LEFT Command 20 6.55 LENS SHIFT RIGHT Command 20 6.56 AUTO PC ADJ. Command 16 6.33 INPUT 3 VIDEO Command 16 ... 21 6.62 KEYSTONE ← Command 21 7 Status Read Command 22 7.1 Format ...22 7.2 Transfer Example 22 7.3 Operation Requirements 22 3/27 PLC-HP7000L Basic Serial Command Functional Specifications 6.27 POWER MANAGEMENT READY1 Command 15 6.28 POWER MANAGEMENT CANCEL Command 16 6.29 POWER MANAGEMENT READY2 Command 16 6.30...
... 1 DVI (PC DIGITAL) Command 19 6.51 INPUT 1 DVI (AV HDCP) Command 19 6.52 LENS SHIFT UP Command 20 6.53 LENS SHIFT DOWN Command 20 6.54 LENS SHIFT LEFT Command 20 6.55 LENS SHIFT RIGHT Command 20 6.56 AUTO PC ADJ. Command 16 6.33 INPUT 3 VIDEO Command 16 ... 21 6.62 KEYSTONE ← Command 21 7 Status Read Command 22 7.1 Format ...22 7.2 Transfer Example 22 7.3 Operation Requirements 22 3/27 PLC-HP7000L Basic Serial Command Functional Specifications 6.27 POWER MANAGEMENT READY1 Command 15 6.28 POWER MANAGEMENT CANCEL Command 16 6.29 POWER MANAGEMENT READY2 Command 16 6.30...
RS232C Basic
Page 6
PLC-HP7000L Basic Serial Command Functional Specifications 3. Please see [7. Z). 6/27 However, for Status Read Command, the function is executed in 500 ms after receiving ACK value for ... data) ・ The pipelining of Functional Execution Command, allow the following interval time after receiving return value. 1) Commands "ZOOM UP/DOWN", "FOCUS UP/DOWN" and "LENS-SHIFT UP/DOWN/RIGHT" --> 100ms 2) Other commands --> 500ms ・ For the pipelining of Status Read Command, allow more than 500 ms of interval time after...
PLC-HP7000L Basic Serial Command Functional Specifications 3. Please see [7. Z). 6/27 However, for Status Read Command, the function is executed in 500 ms after receiving ACK value for ... data) ・ The pipelining of Functional Execution Command, allow the following interval time after receiving return value. 1) Commands "ZOOM UP/DOWN", "FOCUS UP/DOWN" and "LENS-SHIFT UP/DOWN/RIGHT" --> 100ms 2) Other commands --> 500ms ・ For the pipelining of Status Read Command, allow more than 500 ms of interval time after...
RS232C Basic
Page 8
PLC-HP7000L Basic Serial Command Functional Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 ... ON FREEZE OFF --ZOOM ZOOM + ----FOCUS FOCUS + ------INPUT 1 HDMI INPUT 1 ANALOG RGB INPUT 1 SCART INPUT 1 DVI (PC Digital) INPUT 1 DVI (AV HDCP Lens Shift Up Lens Shift Down Lens Shift Left Lens Shift Right Command C80 C81 C82 C83 C84 C85 C86 C87 C88 C89 C8A C8B C8C C8D C8E C8F C90 C91 C92...
PLC-HP7000L Basic Serial Command Functional Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 ... ON FREEZE OFF --ZOOM ZOOM + ----FOCUS FOCUS + ------INPUT 1 HDMI INPUT 1 ANALOG RGB INPUT 1 SCART INPUT 1 DVI (PC Digital) INPUT 1 DVI (AV HDCP Lens Shift Up Lens Shift Down Lens Shift Left Lens Shift Right Command C80 C81 C82 C83 C84 C85 C86 C87 C88 C89 C8A C8B C8C C8D C8E C8F C90 C91 C92...
RS232C Basic
Page 11
...even if it receives the other command. 6.4.2 Functional Execution Commands are invalid when projector is in Standby mode menu. 11/27 PLC-HP7000L Basic Serial Command Functional Specifications 6.4 Operation Requirements 6.4.1 In the following status of projector, Available Functional Execution Commands are executed during...8594; Countdown is terminated C46: ZOOM C47: ZOOM + C4A: FOCUS C4B: FOCUS + C5D: LENS SHIFT UP C5E: LENS SHIFT DOWN C5F:LENS SHIFT LEFT C60:LENS SHIFT RIGHT Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status Abnormal Power Status...
...even if it receives the other command. 6.4.2 Functional Execution Commands are invalid when projector is in Standby mode menu. 11/27 PLC-HP7000L Basic Serial Command Functional Specifications 6.4 Operation Requirements 6.4.1 In the following status of projector, Available Functional Execution Commands are executed during...8594; Countdown is terminated C46: ZOOM C47: ZOOM + C4A: FOCUS C4B: FOCUS + C5D: LENS SHIFT UP C5E: LENS SHIFT DOWN C5F:LENS SHIFT LEFT C60:LENS SHIFT RIGHT Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status Abnormal Power Status...
RS232C Basic
Page 18
...ACK] [CR] Unacceptable "?" [CR] 6.41 FREEZE ON Command Command "C43" [CR] Detail Freeze on -screen focus by making focal length longer. (The lens moves backward) This command works the same way as "ZOOM ▲" button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.... "C46" [CR] Detail Reduce image size This command works the same way as "SELECT" button of the projector and remote control. PLC-HP7000L Basic Serial Command Functional Specifications 6.40 ENTER Command Command "C3F" [CR] Detail This command works the same way as "ZOOM ▼"...
...ACK] [CR] Unacceptable "?" [CR] 6.41 FREEZE ON Command Command "C43" [CR] Detail Freeze on -screen focus by making focal length longer. (The lens moves backward) This command works the same way as "ZOOM ▲" button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.... "C46" [CR] Detail Reduce image size This command works the same way as "SELECT" button of the projector and remote control. PLC-HP7000L Basic Serial Command Functional Specifications 6.40 ENTER Command Command "C3F" [CR] Detail This command works the same way as "ZOOM ▼"...
RS232C Basic
Page 19
... of the remote control. Response Acceptable [ACK] [CR] 19/27 Command Command "C4A" [CR] Detail Adjust on-screen focus by making focal length shorter. (The lens moves forward) This command works the same way as "FOCUS ▼" button of Input 1. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.49 INPUT 1 SCART Command Command... RGB input in Input 1. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. PLC-HP7000L Basic Serial Command Functional Specifications 6.46 FOCUS -
... of the remote control. Response Acceptable [ACK] [CR] 19/27 Command Command "C4A" [CR] Detail Adjust on-screen focus by making focal length shorter. (The lens moves forward) This command works the same way as "FOCUS ▼" button of Input 1. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.49 INPUT 1 SCART Command Command... RGB input in Input 1. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. PLC-HP7000L Basic Serial Command Functional Specifications 6.46 FOCUS -
RS232C Basic
Page 20
...command works the same way as "P-TIMER" button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.54 LENS SHIFT LEFT Command Command "C5F" [CR] Detail Move projection area leftward. process terminates the operation. Response Acceptable [ACK] [CR] ... button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 20/27 PLC-HP7000L Basic Serial Command Functional Specifications Unacceptable "?" [CR] 6.52 LENS SHIFT UP Command Command "C5D" [CR] Detail Move projection area upward. Sending this command during ...
...command works the same way as "P-TIMER" button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.54 LENS SHIFT LEFT Command Command "C5F" [CR] Detail Move projection area leftward. process terminates the operation. Response Acceptable [ACK] [CR] ... button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 20/27 PLC-HP7000L Basic Serial Command Functional Specifications Unacceptable "?" [CR] 6.52 LENS SHIFT UP Command Command "C5D" [CR] Detail Move projection area upward. Sending this command during ...
RS232C Expand
Page 57
Return the Lens to center position This command is carried out with receiving the command another time. *When transmit command of CF_KEYEMU parameter - When User menu is displayed: ..." is non-practice. operation "LENSSHIFT" --------- Then a cursor doesn't toggle and "000" is started with "AUTOPC" command, it does not stop with having displayed User menu. - PLC-HP7000L Expand Serial Command Functional Specifications 8.10 Other Commands 8.10.1 CF_KEYEMU Command Command "CF_KEYEMU_%1" [CR] "RIGHT Move Pointer rightward in On-Screen Display Menu "LEFT Move...
Return the Lens to center position This command is carried out with receiving the command another time. *When transmit command of CF_KEYEMU parameter - When User menu is displayed: ..." is non-practice. operation "LENSSHIFT" --------- Then a cursor doesn't toggle and "000" is started with "AUTOPC" command, it does not stop with having displayed User menu. - PLC-HP7000L Expand Serial Command Functional Specifications 8.10 Other Commands 8.10.1 CF_KEYEMU Command Command "CF_KEYEMU_%1" [CR] "RIGHT Move Pointer rightward in On-Screen Display Menu "LEFT Move...
IR Command
Page 1
... button transmit code for PC mouse operation button (in 8 directions). PLC-HP7000L IR Command List □ Transmission format of LCD projector operation key : NEC Format (single command / command pipelining mode) □ Transmission format of PC mouse operation button (mouse cursor button) / L / R key : Sanyo Mouse Code Format (Includes 3 bit of ID) □ Custom Code...
... button transmit code for PC mouse operation button (in 8 directions). PLC-HP7000L IR Command List □ Transmission format of LCD projector operation key : NEC Format (single command / command pipelining mode) □ Transmission format of PC mouse operation button (mouse cursor button) / L / R key : Sanyo Mouse Code Format (Includes 3 bit of ID) □ Custom Code...
Sanyo's Family of QuaDrive projectors
Page 2
... images remarkable levels of dust Dust Brush Clean filter surface • Available for : PLC-HF10000L, XF1000, HP7000L, XP200L X 0.7 Screen Color control device Projection lens Prism Red Prism Color control device Blue YeGllroewen Independent control of the projector-it is therefore...particles are captured by approximately 20% compared with priority on color reproduction Specifications Newly Developed Active Maintenance Cleaner (AMC) SANYO's new projectors employ an Active Maintenance Cleaner (AMC) that automatically cleans the filter on filter Automatic brushing for ...
... images remarkable levels of dust Dust Brush Clean filter surface • Available for : PLC-HF10000L, XF1000, HP7000L, XP200L X 0.7 Screen Color control device Projection lens Prism Red Prism Color control device Blue YeGllroewen Independent control of the projector-it is therefore...particles are captured by approximately 20% compared with priority on color reproduction Specifications Newly Developed Active Maintenance Cleaner (AMC) SANYO's new projectors employ an Active Maintenance Cleaner (AMC) that automatically cleans the filter on filter Automatic brushing for ...