Popular Sanyo PLC-HP7000L Manual Pages
Print Specs - Page 1
...use. CRESTRON ROOMVIEWTM /AMX DEVICE DISCOVERY COMPATIBILITY PLC-HP7000L supports Crestron RoomViewTM and AMX Device Discovery which darken the screen in color reproduction for mouse)
Warranty
Three years parts and labor; 90 days original lamp; VARIOUS FEATURES FOR VERSATILE INSTALLATION When blending 2 or more projectors, the projector has versatile functions. 'Edge Blending' function allows...
RS232C Basic - Page 1
BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS
PLC-HP7000L Ver.1.00
SANYO Electric Co., Ltd DS Company
Projector Division
RS232C Basic - Page 5
...Connection
Dedicated serial cable must be changed in service mode.
2.2. Transmission speed: initial setting value is specified by control software of the computer.
5/27 PLC-HP7000L Basic Serial Command Functional Specifications
1. Overview
・ These specifications define projector control commands for PLC-HP7000L. ・ The projector control commands are used for the connection...
RS232C Basic - Page 11
... become enable to Lamp Failure
Input button:Mode2 / Mode3 setting
When ZOOM+/-, FOCUS +/-, LENS SHIFTUP/ DOWN/LEFT/RIGHT are limited. PLC-HP7000L Basic Serial Command Functional Specifications
6.4 Operation Requirements
6.4.1 In the following status of projector, Available Functional Execution Commands are executed during Countdown is in standby and "Eco" mode
selected in process...
RS232C Basic - Page 17
... the same way as "
PLC-HP7000L Basic Serial Command Functional Specifications
6.34 INPUT 3 S-VIDEO Command
Command "C34" [CR]
Detail
Select S-Video input in Input 3. Response Acceptable
[ACK] [CR]
Unacceptable "?" [CR]
6.35 INPUT 3 Y,Pb/Cb,Pr/Cr Command
Command "C35" [CR]
Detail
Select Y,Pb/Cb,Pr/Cr input in Input 3. Although projector returns "OK", Input...
RS232C Basic - Page 18
...image This command works the same way as "SELECT" button of the projector and remote control.
Response Acceptable
[ACK] [CR]
Unacceptable "?" [CR]...9650;" button of the remote control. PLC-HP7000L Basic Serial Command Functional Specifications
6.40 ENTER Command
Command "C3F" ...on -screen focus by making focal length longer. (The lens moves backward)
This command works the same way as "FREEZE...
RS232C Basic - Page 22
....
7.2 Transfer Example
Information for Input mode of projector can be obtained by Basic Commands.
"CR" Command [CR] Command: one character (See Status Read Command Table)
・ When projector receives an appropriate command, it returns the required data in the following format. PLC-HP7000L Basic Serial Command Functional Specifications
7 Status Read Command 7.1 Format
・ PC issues...
RS232C Basic - Page 23
... When the status is Standby, Status Read Commands are not accepted except for projector's reliability. When lamp turns off and about 90 seconds of POWER ON; PLC-HP7000L Basic Serial Command Functional Specifications
7.4 Status Read Command
Command "CR0" [CR]
Detail
Get the projector's operating status
Acceptable "%1" [CR]
"00" = Power ON
"80" = Standby
"40" = Countdown in...
RS232C Expand - Page 1
PLC-HP7000L Expand Serial Command Functional Specifications
EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS
PLC-HP7000L Ver. 1.00
SANYO Electric Co., Ltd DS Company
Projector Division
1/94
RS232C Expand - Page 19
..., it returns error code which
shows the status.
19/94 PLC-HP7000L Expand Serial Command Functional Specifications
8 Functional Execution Command 8.1 Format
1) PC issues commands in format as below : Pattern1: "CF_ COMMAND" [CR] Pattern2: "CF_ COMMAND _" %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter)
2) The projector decodes the received...
RS232C Expand - Page 21
... controlled value of Sharpness (Available only in the normal Power ON
status) The value set by this command will not be stored in Suspend mode.)
Acceptable "000" [CR]
Unacceptable "Error Code" [CR]
21/94
PLC-HP7000L Expand Serial Command Functional Specifications
8.4.5 CF_COLMNSAV Command
Command "CF_COLMNSAV_%1" [CR]
%1
"000 - 009 Specify the area to store
Details
Store current...
RS232C Expand - Page 90
... 2 is set on the menu
"OFF PIN code lock OFF is set to OFF on the menu B) PJ lock is entered. Enable to release Shutter with only
"SHUTTER" key
Unacceptable "Error Code" [CR]
9.10.53 CR_SHUTH Command
Command "CR_SHUTH" [CR]
Details
Get time setting to release Shutter with any key
%1
"SHUTTER" -----
PLC-HP7000L Expand Serial Command Functional Specifications
%1 Unacceptable...
IR Command - Page 1
...
ZOOM -
30
4B
FOCUS -
(Number 0)
31
1A
FILTER
32
07
PIP
*1・・・ JOYSTICK button transmit code for PC mouse operation button (in 8 directions). PLC-HP7000L IR Command List
□ Transmission format of LCD projector operation key : NEC Format (single command / command pipelining mode)
□ Transmission format of PC mouse operation button (mouse...
Sanyo's Family of QuaDrive projectors - Page 1
SANYO's Family of QuaDrive Projectors
Advanced Technologies Designed for the Professional
PLC-HF15000L PLC-HF10000L PLC-XF1000 PLC-HP7000L PLC-XP200L
PLC-XP200L
XGA 7000 lm
PLC-HP7000L
1080p 7000 lm
PLC-XF1000
XGA 12000 lm
PLC-HF10000L
2K 10000 lm
PLC-HF15000L
2K 15000 lm
Sanyo's Family of QuaDrive projectors - Page 2
...
F Stop
2.3 2.5 2.1-2.8 2.5-3.1 1.7-2.1 1.7-2.0 2.1-2.8 2.0-2.9 2.1-2.7 2.2-2.7
SANYO. . . If the volume is less than full HD, to clean the filter.
This value is set in reference to the use any tools.
• Available for 12,000
hours*1, without compression.
• 2K: PLC-HF15000L, HF10000L • 1080p: PLC-HP7000L
2K (2048 x 1080)