Rheem P-M407 Support and Manuals

Get Help and Manuals for this Rheem item

View All Support Options Below
Free Rheem P-M407 manuals!
Problems with Rheem P-M407?

Ask a Question

Most Recent Rheem P-M407 Questions

Starting Heater
When engage heater, system sparks but the system does not start. I remove the front cover of the cab...
(Posted by tuckerjoe 9 years ago)
The Digital Display On The Front Of The Heater Is  out I'm Replacing.
what am i in for after its replaced . right now when i turn the heater on the blower only comes on
(Posted by geb4him 10 years ago)

Popular Rheem P-M407 Manual Pages

Brochure - Page 2

... set- Rheem also uses this existing commercial technology on with its exclusive low-profile design. POOL & SPA HEATERS Model 206 266 336 406 BTUH Input 199,500 266,000 332,500 399,000 Wind-Resistant Design Performance and reliability are enhanced by pressing an up or down temperature control button. Rheem engineered the Unitherm Governor specifically for Rheem...
Operating Instructions - Page 3

... SPECIFICATIONS 40 Heat Exchanger Removal 11 SECTION 3 40 Tube Cleaning Procedure INSTALLATION INSTRUCTIONS 40 Desooting Procedure 11 Code Requirements 40 Combustion Chamber Removal 12 Clearances 40 Immersion Well Replacement 12 Outdoor Heater Installation 41 Unitherm Governor (U.G.) Replacement 14 Florida and Texas Building Codes 41 Lo NOx Pool Heaters 15 Indoor Heater Installation...
Operating Instructions - Page 11

.... GENERAL SPECIFICATIONS These heaters are intended only for Gas-Fired Pool Heaters. If necessary, the top can be installed under the latest requirements of heating equipment and related system components. However, following sustained exposure to humans. IMPORTANT NOTICE These instructions are design-certified and tested under the heater. WARNING: Improper installation, adjustment...
Operating Instructions - Page 12

... clearances from combustible construction, the pool heater can still be located in heater carton) 2. WARNING: The heater shall not be serviced without movement or removal of the heater. WARNING: Do not install within 3 feet of the heater to service either case, the heater must be serviced without removing any structure around the heater. Strong air intake from combustible surfaces...
Operating Instructions - Page 13

... the heater. Roof water drainage must be open in Canada, pool heaters shall not be installed under an overhang of less than three 3 ft from , or 1 ft above any building. Heaters must not be installed with the Florida or Texas Building Code, follow the directions on page 14 for the installation of hurricane tie-down brackets for all models...
Operating Instructions - Page 15

... plate (3) Mounting brackets (clips) (3) Screws (1) Instructions Clips Model 206A/207A 266A/267A 336A/337A 406A/407A OUTDOOR STACK Part No. 009834 009835 009836 009837 INDOOR STACK Part No. 009838 009839 009840 009841 ** REFER TO INSTALLATION INSTRUCTIONS INSIDE BOX FOR INSTRUCTIONS ON HOW TO INSTALL OUTDOOR/INDOOR STACK. 15 Failure to the outside . Locate heater as close as is shown...
Operating Instructions - Page 19

...Support must be tested after installation in . All gas piping should be used as specified in vertical height above the drafthood outlet. WC upstream pressure under load and no -load conditions must be at test pressures in . The weight of the heater gas controls, and a manual...compliance with applicable codes. However single-wall metal vent pipe may be adequately supported to gas ...
Operating Instructions - Page 23

... installed in a vertical position. From Heater To Heater CAST IRON HEADER PRV (ASME MODELS) To Pool/ Spa From Pool/ Spa AUXILIARY BYPASS VALVE (DO NOT USE GATE VALVE) AUXILIARY BYPASS VALVE ADJUSTMENT To set ...50°F. Valve lever should be installed, is 125 psi. Bypass Disc To conform to local building codes, it may be tripped at the heater. This valve is required to ...
Operating Instructions - Page 24

... (Standard models only). 24 a solar system, must therefore be down stream of adjacent area. PVC pipe may be located so that the control panel will not damage the structure of the pool heater). It must be connected to the main line ahead of the heater is plumbed as the primary heat source. A typical installation is...
Operating Instructions - Page 27

... Lo NOx pool heaters attach a wire nut to the heater from the GFCI power source. If using a switched GFCI power source, the heater could display false service indicators on ...HEATER 7 WIRES GREEN GREEN RED RED RED 240 VAC WIRING For 240 VAC input power to the unit, connect the black wire to the white wire for 240 VAC operation. Canadian Electrical Code, CSA C22.1, Part 1 and Part...
Operating Instructions - Page 33

... indicates the total hours of operation for the pool heater, as measured by the amount of the heater, allows the user to select either POOL or SPA operation. A manual power switch provided below the setpoint and the heater is in the Service Menu. SUPPLY VOLTAGE INDICATOR Operation In the POOL or SPA modes, the actual water temperature is...
Operating Instructions - Page 38

... copper wire rated for deck-level installations. MAX NOTE: If heater is running, check the adjustment by warranty. This is being supplied by excessive restriction in operation. Both are set to the heater. TWO-SPEED PUMPS In some cases, the flow on both millivolt and AFT heaters must be replaced when disabled by an over-temperature...
Operating Instructions - Page 41

... POOL HEATERS The Lo NOx pool heaters are equipped with all local codes, and the latest editions of operation, the flames should be observed through the opening below the plenum. c. After about five minutes of the National Fuel Gas Code Z223.1 and the National Electrical Code, ANSI/NFPA 70. The baffle has a hole that electrical service to the heater...
Technical Data - Page 2

... favorite setting just by eliminating the need for a continuous pilot. • Low Emissions The Rheem Low NOx gas heater complies with the heater at a rate up or down temperature control buttons. • Self-Diagnostic On-board diagnostic controls let the user and the service professional know that the pilot should be installed without notice Swimming Pool and...
Warranty - Page 2

...KEEP IT WITH YOUR POOL HEATER OR BUSINESS RECORDS. If the dealer is repaired or altered in the event warranty service is the only warranty given by Raypak. Name of Owner Name of Installer Owners Address Installers Address Date of Pool Heater Installation Telephone Number of Installer Model Number of Your Pool Heater Serial Number of installation. Proper authorization MUST be...

Rheem P-M407 Reviews

Do you have an experience with the Rheem P-M407 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Rheem yet.

Popular Rheem P-M407 Search Terms

The following terms are frequently used to search for Rheem P-M407 support:

Ask a New Question
Use the box below to post a new question about Rheem P-M407.
Manuals / Documents
Download any of our Rheem P-M407 manuals for free!

We have the following 4 documents available for the Rheem P-M407:
  • Operating Instructions
  • Brochure
  • Technical Data
  • Warranty

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Rheem Manuals

Find free Rheem P-M407 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Rheem Reviews

View thousands of Rheem P-M407 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Rheem customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Rheem customer service rankings, employee comments and much more from our sister site.

Rheem Recalls

Find comprehensive Rheem recall information updated hourly on RecallOwl.com.