Instruction Manual
Page 1
... permanently adhered to the cover of the Quick Start Guide which is removable for your convenience. 10002793-A 1/27/15 Power Cord • AVM & Protect-or-Disconnect Circuitry Important: You will need the M4000-PRO's unique MAC Address and Challenge Key (provided on the 2 labels attached to the Quick Start Guide and the other...
... permanently adhered to the cover of the Quick Start Guide which is removable for your convenience. 10002793-A 1/27/15 Power Cord • AVM & Protect-or-Disconnect Circuitry Important: You will need the M4000-PRO's unique MAC Address and Challenge Key (provided on the 2 labels attached to the Quick Start Guide and the other...
Instruction Manual
Page 2
...-283-5901 ®2015 Core Brands LLC. Four silicone rubber feet for the M4000-PRO. Panamax and BlueBOLT are grouped into three (3) switched banks. Introduction Thank you for purchasing a Panamax M4000-PRO Power Management with cup washers for rack mounting. Removable rack ears included (attached) Panamax, 1800 S. All rights reserved. Box should contain the following, including the Quick...
...-283-5901 ®2015 Core Brands LLC. Four silicone rubber feet for the M4000-PRO. Panamax and BlueBOLT are grouped into three (3) switched banks. Introduction Thank you for purchasing a Panamax M4000-PRO Power Management with cup washers for rack mounting. Removable rack ears included (attached) Panamax, 1800 S. All rights reserved. Box should contain the following, including the Quick...
Instruction Manual
Page 3
..." delay for this line. The M4000-PRO also provides surge protection for custom applications. LAN Protection: Protection circuits for TV show scheduling and/or Pay-Per-View services. This minimizes inrush current issues by Panamax if this power signal will disconnect your satellite receiver ...from 0 Hz to voltage transients generated internally at the same time. Voltage Sense Trigger: The M4000-PRO voltage sense trigger input uses a standard 3.5mm ...
..." delay for this line. The M4000-PRO also provides surge protection for custom applications. LAN Protection: Protection circuits for TV show scheduling and/or Pay-Per-View services. This minimizes inrush current issues by Panamax if this power signal will disconnect your satellite receiver ...from 0 Hz to voltage transients generated internally at the same time. Voltage Sense Trigger: The M4000-PRO voltage sense trigger input uses a standard 3.5mm ...
Instruction Manual
Page 4
Heed all servicing to qualified service personnel. A grounding type plug has two blades and a third grounding prong. Front Panel Features Overview M4000-PRO 1 2 3 3. Outlet Bank 1, 2, 3 Buttons: The blue light above each outlet bank button indicates its present ON/OFF state. Wiring Fault...: Illuminates red if the house wiring is reverse-wired or the ground is provided for your outlet, consult an electrician for temporarily powering portable equipment. BlueBOLT: This light indicates the status of the polarized or grounding type plug. Not connected to an active local area...
Heed all servicing to qualified service personnel. A grounding type plug has two blades and a third grounding prong. Front Panel Features Overview M4000-PRO 1 2 3 3. Outlet Bank 1, 2, 3 Buttons: The blue light above each outlet bank button indicates its present ON/OFF state. Wiring Fault...: Illuminates red if the house wiring is reverse-wired or the ground is provided for your outlet, consult an electrician for temporarily powering portable equipment. BlueBOLT: This light indicates the status of the polarized or grounding type plug. Not connected to an active local area...
Instruction Manual
Page 5
Ground lug: Connect to Panamax MOD-series signal protection module grounding busses with 14AWG ( AC Inlet: 120 VAC, 15A, IEC 320-C13 do not remove steel retention clip. 2. Rear Panel Features Overview 2. Circuit Breaker: 120 Vac, 15A 3. MAIN POWER 15A BANK 3 BANK 3 BANK 2 BANK 2 GND 120 VAC/15A 1. 3. 4. 1.
Ground lug: Connect to Panamax MOD-series signal protection module grounding busses with 14AWG ( AC Inlet: 120 VAC, 15A, IEC 320-C13 do not remove steel retention clip. 2. Rear Panel Features Overview 2. Circuit Breaker: 120 Vac, 15A 3. MAIN POWER 15A BANK 3 BANK 3 BANK 2 BANK 2 GND 120 VAC/15A 1. 3. 4. 1.
Instruction Manual
Page 6
... software for details on M4000-PRO. (Note: adding a device to your home/office network may also be accessed via Panamax/Furman's hosted BlueBOLT platform, M4000-PRO may require a power cycle of the router/modem to connect your M4000-PRO component, please contact Panamax customer service at default ...™ Note: You will use two IP addresses on the local area network. Your BlueBOLT® enabled M4000-PRO Power Management Component is up , M4000-PRO will need the M4000-PRO's unique MAC ADDRESS and CHALLENGE KEY (duplicate labels provided in your internet router or modem?
... software for details on M4000-PRO. (Note: adding a device to your home/office network may also be accessed via Panamax/Furman's hosted BlueBOLT platform, M4000-PRO may require a power cycle of the router/modem to connect your M4000-PRO component, please contact Panamax customer service at default ...™ Note: You will use two IP addresses on the local area network. Your BlueBOLT® enabled M4000-PRO Power Management Component is up , M4000-PRO will need the M4000-PRO's unique MAC ADDRESS and CHALLENGE KEY (duplicate labels provided in your internet router or modem?
Instruction Manual
Page 7
... or recovery from an under-voltage shutoff, the outlet banks will return to their pre-fault power state regardless of the DC trigger status. M4000-PRO Specifications AC POWER Operating Voltage 120 Vac / 60Hz Current Capacity 15 A UL 1449 Voltage Protection Rating 330V L-N, 400V L-G, 400V N-G UL 1449 ..."F", Gold-plated Insertion loss Trigger Enable: When enabled, the outlet bank will turn OFF after the Turn Off Delay time. When the M4000-PRO is powered-up , recovery from a fault condition, the DC trigger input going from 0V to 5-24VDC or the command is received on the ...
... or recovery from an under-voltage shutoff, the outlet banks will return to their pre-fault power state regardless of the DC trigger status. M4000-PRO Specifications AC POWER Operating Voltage 120 Vac / 60Hz Current Capacity 15 A UL 1449 Voltage Protection Rating 330V L-N, 400V L-G, 400V N-G UL 1449 ..."F", Gold-plated Insertion loss Trigger Enable: When enabled, the outlet bank will turn OFF after the Turn Off Delay time. When the M4000-PRO is powered-up , recovery from a fault condition, the DC trigger input going from 0V to 5-24VDC or the command is received on the ...
Instruction Manual
Page 8
... of Installation MAC ADDRESS CHALLENGE KEY Phone Number(s 6 Identify Connected Equipment Use this diagram to right. OUTLET 5 OUTLET 4 OUTLET 6 OUTLET 3 OUTLET 7 OUTLET 2 LAN OUTLET 1 MAIN POWER 120 VAC/15A 15A GND 7 BANK 3 6 5 WIRING FAULT UNSAFE VOLTAGE BlueBOLT FRONT PANEL OUTLET ENABLED BANK 2 4 3 BANK 1 2 1 IN CATV / SAT 1 OUT IN PHONE OUT IN...
... of Installation MAC ADDRESS CHALLENGE KEY Phone Number(s 6 Identify Connected Equipment Use this diagram to right. OUTLET 5 OUTLET 4 OUTLET 6 OUTLET 3 OUTLET 7 OUTLET 2 LAN OUTLET 1 MAIN POWER 120 VAC/15A 15A GND 7 BANK 3 6 5 WIRING FAULT UNSAFE VOLTAGE BlueBOLT FRONT PANEL OUTLET ENABLED BANK 2 4 3 BANK 1 2 1 IN CATV / SAT 1 OUT IN PHONE OUT IN...
Instruction Manual
Page 10
Information elements are enclosed in the element. Query Response Send Information Query The Send Information query is used to retrieve the following system-level information from the M4000-PRO.
Information elements are enclosed in the element. Query Response Send Information Query The Send Information query is used to retrieve the following system-level information from the M4000-PRO.
Instruction Manual
Page 11
... within a element. For a turn on delay time. Command Attribute: id = "bank" Content None Example: Power cycle an outlet bank Which outlet bank to control Power cycle outlet bank 1 Power Sequence Command the M4000-PRO to turn OFF, wait for its power cycle delay time and then turn on sequence, the outlet banks will turn off after...
... within a element. For a turn on delay time. Command Attribute: id = "bank" Content None Example: Power cycle an outlet bank Which outlet bank to control Power cycle outlet bank 1 Power Sequence Command the M4000-PRO to turn OFF, wait for its power cycle delay time and then turn on sequence, the outlet banks will turn off after...
Instruction Manual
Page 12
...the trigger enable for an outlet bank Set delay settings for 60 second power cycle delay Set bank 2 trigger enable to enabled Set brightness to level 3 10 connection to BlueBOLT is reestablished Command Reboot M4000-PRO Attribute: None Content None Example: Set Settings This command is restored; are... restored to their on/off ; Set the front panel LED brightness Brightness level, out of the M4000-PRO configuration settings. Reboot Command the M4000-PRO to reboot all of the parameters when using this command. Upon reboot, all outlets will turn off state prior...
...the trigger enable for an outlet bank Set delay settings for 60 second power cycle delay Set bank 2 trigger enable to enabled Set brightness to level 3 10 connection to BlueBOLT is reestablished Command Reboot M4000-PRO Attribute: None Content None Example: Set Settings This command is restored; are... restored to their on/off ; Set the front panel LED brightness Brightness level, out of the M4000-PRO configuration settings. Reboot Command the M4000-PRO to reboot all of the parameters when using this command. Upon reboot, all outlets will turn off state prior...
Instruction Manual
Page 13
...power on sequence initiated 2 = turn ON->OFF or OFF->ON. It may be sent. A sample event element: ... they are not replies to Event Messages After start -up. A subscriber ID, "subsid" is assigned to 10 decimal digit characters and represents the number of seconds that have event messages sent from a M4000-PRO...event messages. Only one IP address / port event subscription is allowed. The time attribute is a UNIX timestamp, up , M4000-PRO will contain a timestamp attribute, "time", and an event ID attribute, "evtid". The event subscription command is enclosed within the...
...power on sequence initiated 2 = turn ON->OFF or OFF->ON. It may be sent. A sample event element: ... they are not replies to Event Messages After start -up. A subscriber ID, "subsid" is assigned to 10 decimal digit characters and represents the number of seconds that have event messages sent from a M4000-PRO...event messages. Only one IP address / port event subscription is allowed. The time attribute is a UNIX timestamp, up , M4000-PRO will contain a timestamp attribute, "time", and an event ID attribute, "evtid". The event subscription command is enclosed within the...
Instruction Manual
Page 14
Element Tag: Attribute: None Content 0 | 1 | 2 | 3 0 = power normal 1 = fault recovery 2 = under voltage 3 = over -voltage or under-voltage shutdown mode. Information for all settings is ... as outlet bank delays, outlet bank trigger enable and display brightness is changed . Element Tag: Attribute: None Content ... ... ... Example: 12 Power Condition A Power Condition event is posted when the unit enters or recovers from the DC trigger input jack. Element Tag: Attribute: None Content 0 | 1 0...
Element Tag: Attribute: None Content 0 | 1 | 2 | 3 0 = power normal 1 = fault recovery 2 = under voltage 3 = over -voltage or under-voltage shutdown mode. Information for all settings is ... as outlet bank delays, outlet bank trigger enable and display brightness is changed . Element Tag: Attribute: None Content ... ... ... Example: 12 Power Condition A Power Condition event is posted when the unit enters or recovers from the DC trigger input jack. Element Tag: Attribute: None Content 0 | 1 0...
Instruction Manual
Page 16
...or more of this equipment. All equipment being returned for servicing. We suggest that you require technical support or equipment service, please contact Panamax Tech Support at 800-472-5555. However, there is insured. Also, please enclose a note giving your name, address, phone number... has been tested and found to comply with the instructions, may also email info@Panamax.com. CAUTION: A shielded-type power cord is required in shipment, and that only the supplied power cord be specified in residential installation. Contacting Tech Support If you save the original ...
...or more of this equipment. All equipment being returned for servicing. We suggest that you require technical support or equipment service, please contact Panamax Tech Support at 800-472-5555. However, there is insured. Also, please enclose a note giving your name, address, phone number... has been tested and found to comply with the instructions, may also email info@Panamax.com. CAUTION: A shielded-type power cord is required in shipment, and that only the supplied power cord be specified in residential installation. Contacting Tech Support If you save the original ...